One doorset may carry three duties at once: hold against attack, lock down fast, and release for fire escape. The hardware must pass all three, and the buyer checks the lock against each duty in turn.
- RatingLPS 1175 Issue 8.2 (September 2024)
- Fail-safeReleases when the power fails
- Fail-secureStays locked when the power fails
- EscapePanic fastenings above 60 people
Three duties on one doorset
A rated door that also locks down and also serves as a fire escape carries three duties, and the three meet at the lock. The rating asks the leaf, the frame and the hardware to hold for the delay the grade promises. The lockdown asks the same hardware to secure the leaf in seconds, from the inside, when the alert sounds. The fire escape asks the same hardware to let people out, with one action, when the alarm sounds. NPSA puts the order plainly: all policies must comply with fire and health and safety legislation, so the security duty never overrules the escape duty.
This guide covers only the rated-door case. The generic choice between fail-safe and fail-secure, for a door with no rating and no lockdown role, is covered in full by the access control doors guide, and the door entry systems guide sets out the same choice for the entry system as a whole. Read those two first: the rated door adds a rule the generic case does not have, and the hardware must keep the rating.
Fail-safe and fail-secure on a rated door
Fail-safe hardware releases when the power fails. The leaf opens, the people leave, and the room is safe but not secure. Fail-secure hardware stays locked when the power fails. The leaf holds, the room stays secure, and the people inside must leave by another route. Approved Document B sets the rule for the escape route: an electrically powered lock must let go when the fire detection and alarm operates, when the power fails, when the system fails, and when the security override is pressed.
A fail-secure lock belongs on a door that is not an escape route: a store, a plant room, a server room with a second way out. A fail-secure lock on an escape route puts the security duty ahead of the escape duty, and the building regulations do not allow that. The Approved Document B Volume 2 sets out the escape rules for doors on escape routes, and the buyer should read the fastenings rules there before choosing a lock for a rated leaf.
The lockdown the door must hold
Lockdown is the securing of doors and barriers to restrict access, and NPSA names four kinds, and the buyer must know which kind each door serves, because the hardware differs for each. A leaf that lets people out but not in needs a lock that opens from the inside. A leaf that holds both ways needs a lock that holds from both sides. A leaf that secures only at certain doors needs its own call, and a leaf that secures only one area needs the doors of that area to act together.
The lockdown must be fast. The procedure names each door and shutter to be secured, says how each is secured, when it is opened again, and who closes it. The emergency services must know how to get in while the building is still locked down, and the standard tier procedures guide shows how the lockdown fits the four procedures of Martyn’s Law. The places of worship guide shows the same lockdown in a building that stays open.
The fire exit the same door must give
The fastenings on an escape route must be simple. Approved Document B asks that a fastening shows at once how it works, opens from the side the people escape from, needs no key, and needs only one action to open the leaf. A door may be locked when the room is empty, and a door with a code, a card or a biometric reader needs a security override that works from the escape side.
A room with more than 60 people inside needs panic fastenings to BS EN 1125, and the leaf must swing in the direction of escape and open to at least 90 degrees. A final exit with a security lock may use that lock only when the building is empty, and the management procedures must say so in plain words. The emergency exit doors guide lists the panic bars, the opening force and the fire exit rules in full, and the panic hardware guide names the bars and the pads themselves.
The override that decides the conflict
The conflict between lockdown and escape is decided by the override. Approved Document B asks for a Type A call point to BS 7273-4, on the escape side of the door, and on both sides where people may escape in either direction. Pressing the call point releases the lock, and the leaf opens. The fire alarm does the same: when the detection and alarm operates, the electrically powered locks let go, and the escape routes open.
NPSA adds the rule for the day itself. A fire inside the building beats a two-way lockdown, because the fire is the greater threat, and the people leave by the escape routes. The procedures must name how the lockdown is ended and the evacuation begun, and the conflict must be resolved with the fire plan before the day, not during it. The NPSA guidance on evacuation, invacuation and lockdown sets out the lockdown types and the fire rules in full.
Hardware that keeps the rating
A rated doorset is tested as a set: the leaf, the frame, the hinges, the lock, the cylinder and the seals, all together. A change to any one of them needs the certificate schedule checked first, because a lock that was not in the test is a lock the rating does not cover. The keeping the rating valid guide names the changes that need fresh evidence and the ones that do not, and the fire door certification guide covers the same question for the fire rating, where the closer, the seals and the hinges carry the same rule.
Panic hardware on a rated leaf must be approved for that doorset, and the schedule must name the hardware as tested. Where the leaf carries a fire rating as well as a security rating, the dual-certified door guide names the checks that keep the two ratings standing together, and the school security doors guide shows how the rated doors, the lockdown and the escape routes are run as one system in a school.
Testing the three duties together
The three duties must be tested together, because a lock that passes each test alone may fail them together. The test has four parts: cut the power and check the leaf releases, sound the fire alarm and check the leaf releases, call the lockdown and check the leaf holds, and press the override and check the leaf releases again. Each part is recorded, with the date, the door and the result, and the record is kept with the certificate schedule.
The test repeats after any change to the hardware, the power supply or the procedures, and it repeats on a regular basis as part of the maintenance round. The acceptance and snagging guide sets out the handover test for a new doorset and barrier, and the maintenance contract guide shows how the test is written into the contract, with the visits, the parts and the record named.
| Duty | What the hardware must do | How it is tested |
|---|---|---|
| Security rating | Hold for the delay the grade promises | Certificate schedule names the hardware |
| Lockdown | Secure the leaf quickly, from the inside | Call the lockdown, check the leaf holds |
| Fire escape | Release with one action, no key | Sound the alarm, check the leaf releases |
| Override | Release the lock from the escape side | Press the call point, check the leaf opens |
One lock, three duties. The hardware earns its place by passing the power cut, the fire alarm and the lockdown call together.
How do fail-safe and fail-secure differ?
Fail-safe lets go when the power fails, so the leaf opens and the people leave. Fail-secure holds when the power fails, so the room stays secure while the people inside leave by another route.
Can a fail-secure lock sit on a fire escape route?
No. The lock on an escape route must let go on four signals: the fire alarm, a power failure, a system failure, and the override. A fail-secure lock goes on a store, a plant room, or any door that is not an escape route.
What does the override do?
The override is a call point to BS 7273-4, Type A, fixed on the escape side. Pressing it lets the lock go, and the leaf opens. The fire alarm releases the lock in the same way when the detection and alarm operates.
Does changing the lock affect the LPS 1175 rating?
It may. The leaf, the frame and the hardware are tested together as one set, and a lock outside that test is a lock the rating leaves out. Check the certificate schedule first, and get fresh evidence where the schedule does not name the lock.
How often should the three duties be tested together?
At handover, after a change to the hardware, the power, or the procedures, and again at each scheduled maintenance visit.