Areas we cover
Security doors and physical security in Nottingham
ArxBridge supplies and installs LPS 1175 security doors, fire rated doorsets and blast protection across Nottingham for commercial and campus sites in the UK.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Nottingham
Get a free quote in Nottingham
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Nottingham
What we supply in Nottingham
Nottingham’s transport interchange funnels thousands of people a day past its commercial quarters, university halls and hospital estate. ArxBridge supplies and installs rated security doors, windows, blast protection and vehicle barriers across the city, specified by architects, main contractors and facilities teams for city centre, campus and hospital projects.
- LPS 1175 SR2 to SR5Forced entry ratings for doors and windows
- EI 30 to EI 120Fire rated steel doorsets
- Ballistic ratings FB4 to FB7Tested to EN 1522
- PAS 68 ratedVehicle impact barriers and bollards
Buildings and sites that need protection in Nottingham
The main transport interchange handles heavy footfall from early morning to late night. Forecourts, taxi ranks and drop-off lanes sit close to entrances and glazing, so the front of house needs two things at once: hostile vehicle mitigation outside and LPS 1175 security doors on plant rooms, ticket offices and back-of-house corridors. Our security bollards are tested to PAS 68, which records vehicle mass, impact speed, impact angle and penetration distance, so a specifier can match the rating to the approach layout. The transport hubs page explains how stations usually zone their protection.
The teaching hospital estate is the city’s largest secure campus. Pharmacies, pathology laboratories and plant rooms need doorsets that hold against forced entry while meeting fire compartmentation, so fire and security doors rated to both EI and LPS 1175 are a common choice. Corridors and service risers take fire rated steel doors from EI 30 to EI 120, tested to EN 1634-1. The healthcare page explains how hospitals zone their secure areas.
Two universities hold estates across the city centre and the suburbs. Student accommodation blocks need communal entrance doors that stand up to daily use and attempted break-ins, typically LPS 1175 SR2 (B3), which gives three minutes against hand tools such as screwdrivers, pliers and hand saws. Research laboratories and data rooms usually step up to SR3 (C5), five minutes against crowbars, drills and chisels. The LPS 1175 guide explains the full rating scale used on education estates.
Retail streets and the commercial quarters bring a different pattern: high-value stock behind full-height glazing by day, empty streets at night. Security shutters and roller doors close that gap, and security windows rated to LPS 1175 protect display fronts that stay glazed. For sites near busy roads, laminated blast resistant glass matched to its frame adds protection against vehicle-borne blasts, with hazard ratings from A (no break) to F (high hazard).
Which rating suits each site
Start from the threat, then pick the rating. The table is a guide only; a site survey confirms what each opening needs.
| Site | Main threat | Rating to specify | Product |
|---|---|---|---|
| Station forecourts and drop-off lanes | Vehicle impact | PAS 68 | Security bollards |
| Hospital pharmacies and plant rooms | Forced entry and fire | EI 60 with LPS 1175 SR3 | Fire and security doors |
| Student accommodation entrances | Forced entry | LPS 1175 SR2 (B3) | Communal entrance doors |
| Retail frontages near busy roads | Forced entry, blast | LPS 1175 SR3, ISO 16933 glazing | Security shutters |
| University data rooms | Forced entry, stealth attack | LPS 1175 SR3, LPS 2081 SRB | Security doors |
Heritage and planning points
Parts of Nottingham fall inside conservation areas, and listed buildings need listed building consent before any change to doors or windows. Where the facade must stay, security sash windows and vacuum insulated glass give a security rating inside a slim, traditional-looking unit. Rated LPS 1270 security glazing can sit behind existing stonework without changing the street view.
Survey first, then specify. Every ArxBridge installation starts with a site survey that records opening sizes, wall construction and access. The doorset that arrives is made to those measurements.
How supply and installation works in Nottingham
ArxBridge supplies and installs across Nottingham and the surrounding county. The process runs assess, specify, manufacture, install and maintain: we survey the site, agree the ratings with your team, manufacture the doorsets to size, fit them with minimal disruption and support them afterwards. Work can be phased so wards, stations and campuses stay in use while installation continues.
Can you fit LPS 1175 doors in an occupied hospital ward?
Yes. Installation is phased so clinical areas stay in use, and each doorset is made to surveyed measurements so fitting time on site is short. Fire compartmentation is maintained throughout the work.
What HVM rating do station forecourts need?
That depends on the approach layout and the risk assessment. PAS 68 ratings state the test vehicle’s mass and the impact speed, commonly 48, 64 or 80 km/h, so the rating should match the fastest realistic approach. A site survey sets out the options.
Can security windows be fitted in a conservation area?
Often, yes. Rated sash windows and slim glazing units are designed to suit historic facades, and work on listed buildings needs listed building consent from the planning authority. We supply drawings and rating evidence to support the application.
Can one doorset carry both fire and security ratings?
Yes. Dual rated assemblies combine an EI fire rating with an LPS 1175 security rating in one doorset, tested for both. They are common in hospitals and transport buildings where compartmentation and forced entry resistance meet.
Get a free quote
Other areas
We also cover
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.