Certified physical security

ArxBridge
Steel door sample in a security test frame with an assessor in a UK test laboratory

ArxBridge

Supermarket Security Doors

A supermarket guards cash, stock and deliveries behind its doors, so each leaf takes the grade the room behind it demands, from the till to the yard.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A supermarket is a shop, a warehouse and a cash office under one roof, and the doors between one part and the next hold the line between them. The sales floor holds the customers, the stock room holds the goods, and the cash office holds the takings, so a door between one part and the next must hold the line between them.

LPS 1175 sets the grade on a supermarket door, and the room behind the leaf decides which category it takes. Issue 8.2, dated September 2024, gives the three categories three, five and ten minutes, named B3, C5 and D10. The entrance takes the lowest of the three, the stock room takes the middle one, and the cash office takes the highest.

The rules for the shared parts of a shop are set out in the fire door regulations retail guide, and the rules for the stores beside the sales floor are set out in the fire door regulations warehouses guide. The store order names every door in the building, with the grade and the lock beside each one, so the door that arrives is the door the room needs.

  • LPS 1175 B3 / C5 / D10Forced entry grades to Issue 8.2
  • Cash officesWhere the grade rises
  • FD30 / FD60Fire periods to EN 1634-1
  • One listEvery store door named

Front of store, stock room and delivery bay: one store, three grades

A supermarket splits into three parts, and the grade follows what each part holds. The sales floor feeds the tills, the stock room feeds the shelves, and the delivery bay feeds them both from the yard, so each part takes the doors its work demands.

The sales floor takes the doors the customers pass through all day, and each leaf must open for a shopper with a trolley and shut behind them without a hand on it. The stock room takes the doors the public never sees, and each leaf must hold against the attack the goods behind it invite.

The store writes its schedule before the order goes out, naming every opening and the grade beside it. A leaf with no line on the schedule may arrive for the wrong room, and the wrong leaf on the cash office guards nothing.

The cash office: the room that takes the highest grade

The cash office holds the takings, and the leaf that guards it takes the highest grade on the order. Leaf, frame, fixings and lock are proved together as one doorset, and the test report names each part, so the door that arrives matches the door that was proved.

A cash office leaf takes D10, because it must hold longest, while the stock room beside it takes C5 and the entrance takes B3. The three categories were called SR2, SR3 and SR4 before Issue 8, and the order names the category the product was proved under. A door ordered to LPS 1175 carries LPS 1175 alone, because no published table turns one standard’s rating into another’s.

The cash office takes a lock the manager controls, and the leaf, the frame and the lock are proved together as one doorset, with the report naming each one. What breaks a rating once a door is fitted is named in the keeping an LPS 1175 rating valid guide.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Stock rooms and the delivery bay: where the value waits

The stock room holds the goods the shelves will need next, and the leaf that guards it takes the grade the value behind it demands. A stock room leaf takes C5, because the goods behind it are worth the time it takes to break through, and the leaf must hold long enough for the alarm to be answered.

The delivery bay takes the same care, because the doors at the back of the store face the yard where anyone can walk up to them. A delivery bay leaf takes C5, and the lock on it takes the same key as the stock room, so the staff who work the bay can open both without carrying two keys.

The delivery bay leaf takes a closer that shuts it after every load, because a leaf left open is a door that guards nothing. The closer is set so the leaf comes home quietly after every load, and the pull is checked by opening the leaf and letting it go. Sizes and fitting for closers are worked through in the fire door closers guide.

The front of the store: the leaves customers meet

The front of the store is the leaf every customer passes, and it must open for a shopper with a trolley and shut behind them without a hand on it. The entrance leaf takes B3, because the public passes through it all day, and the leaf must open with one push from whoever reaches it.

The glass in the entrance leaf takes the same proof as the leaf beside it, because a leaf that holds while its pane fails has held nothing. The test report names the bead and the fixings that hold the pane, and the order carries them beside the glass. The fire rated glass cost guide works through what the glass itself costs.

The entrance doors take a panic bar to BS EN 1125, running across at least 60 percent of the leaf, so one push throws the latch for a crowd. The force to open a leaf on the way out stays below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M.

A store leaf that holds both: fire and forced entry together

One store leaf can carry both proofs at once, because the stock room needs fire held back and an intruder held out. EN 1634-1 writes the fire proof as minutes with letters, E, EW and EI from 30 to 120, and LPS 1175 writes the forced entry proof as B3, C5 and D10. The leaf, the frame and the seals face both tests as one doorset, so the proof for fire and the proof for forced entry sit on the same report.

The period follows the room behind the leaf, because the stock room, the cash office and the sales floor ask different things of the leaf, and the grade follows the value behind it. Minutes run from 30 to 120, and the letters beside the number say what stayed back: flames on their own, flames with some heat, or flames with the heat as well. Smoke seals on the route doors carry a proof to BS EN 1634-3, Sa where the smoke is at room temperature and S200 where it is at 200 degrees. The smoke control doors guide covers how the doors hold smoke back while people move past them.

The gap beside the leaf stays at 4 mm, so the leaf swings without catching and the seal meets the frame all round. Heat near 200 to 250 degrees makes the intumescent seal swell and close the gap the leaf leaves. The fire and security doors dual certification guide works through how two proofs share one doorset.

Locks, readers and the goods-in door: how staff move through the store

The staff route through a supermarket runs from the entrance through the sales floor to the stock room and back, and each leaf on the route opens for staff and stays shut for the public. Each leaf takes a reader beside it, and the list behind the readers names the fobs that open each door. The fire door hardware guide covers the lock the key turns.

The goods-in door takes the deliveries in from the yard, and it takes a leaf wide enough for trolleys and pallets and a lock the staff control. The security door locks guide covers the lock the key turns, and the door entry systems guide covers the readers, releases and wiring beside a leaf.

Before the order goes out, every leaf gets its answer for the night the power fails. The answer sits beside each door on the order, so no leaf is left to guess when it matters most.

The entrance and the checkouts: doors the public passes every day

The checkouts take the doors the customers pass with their trolleys, and each leaf must open for a shopper who has never touched it before. The doors beside the tills take the same care as the entrance, because a leaf that will not open traps the customer behind it.

The doors that guard a shop take the same care with their stores, and the retail security doors guide sets out the doors a shop needs.

The entrance leaf takes the wear of every customer who passes through it, so the hinges, the closer and the seals on the busiest doors belong at the top of the list. A leaf that drags, a closer that has lost its pull, or a seal that has come away from its groove is written beside the door it belongs to, with the part and the day it was found.

The supermarket order: every leaf on one list

The supermarket order is written as one list, with a line for every door in the building and the leaf, the grade, the lock and the closer beside each one, so the door that arrives is the door the sales floor, the stock room and the delivery bay need. A list that names one leaf for the whole store leaves the fitter guessing which room takes which grade, and a leaf in the wrong room guards the wrong thing.

Every leaf, lock, closer and seal on the store is priced from the list before the order goes out, line by line, so the entrance, the cash office and the delivery bay each carry their own figure. The how to specify security doors guide sets out the columns the list needs, and what each step up the scale adds to the price is worked through in the security door cost factors guide.

One day each week the store manager walks the whole estate in a single round, starting at the entrance and ending at the cash office after the stock rooms and the delivery bay. The round opens every leaf, works every lock and watches every closer as the leaf comes back to the frame. Its note stays with the store file, and a leaf that will not close or a lock that will not throw is put right before the next delivery is due. The fire door inspection checklist lists what a visit should cover, and the security door maintenance checklist covers the leaves that must hold fire as well as forced entry.

Position Door Grade What to check
Entrance Glazed leaf LPS 1175 B3 Leaf, glass, reader
Cash office Steel leaf LPS 1175 D10 Leaf, lock, seals
Stock room Steel leaf LPS 1175 C5 Leaf, lock, seals
Delivery bay Steel leaf LPS 1175 C5 Leaf, closer, lock
Plant room Fire leaf FD60 Leaf, seals, gap

A supermarket door holds only as long as the cash behind it and the stock beside it, so the grade, the period and the lock must all sit on the same list.

What grade should a supermarket door carry?

The grade follows the room behind the leaf: B3, C5 or D10 to LPS 1175, with the cash office taking a higher category than the entrance.

Can one leaf hold fire and forced entry?

Yes, when one leaf, frame and seals face both tests together, the one doorset carries the proof for fire and for forced entry.

Do supermarket doors need access control?

A reader beside each leaf behind the sales floor opens it for staff fobs, so the public stays on the shop side of the door.

What period should a stock room door carry?

FD30 or FD60 to EN 1634-1, with letters beside the minutes naming what the doorset held back. The room behind the leaf decides which period the door takes.

Who checks the supermarket doors?

The store manager walks the round that covers every door, and the record of each visit stays with the store file.

Specifying doors for a supermarket?Send the door list and the grade each room must hold for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.