Security Doors for Operating Theatres

An operating theatre suite runs on seven leaves, from the entrance to the sterile store, and each leaf takes the LPS 1175 grade its room needs.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

The entrance leaf of an operating theatre suite carries B3 to LPS 1175 Issue 8.2, and the anaesthetic rooms, the scrub areas and the recovery bays carry the same grade, while the operating theatres, the sterile store and the plant room carry C5.

Issue 8.2 of LPS 1175 reached publication in September 2024, and under that issue a leaf earns its grade from the minutes it stands up to attack, with B3 standing for three minutes, C5 standing for five minutes and D10 standing for ten minutes, while the older names SR2, SR3 and SR4 match B3, C5 and D10 in that order.

A theatre suite holds operating theatres where surgery runs through the list, anaesthetic rooms where patients are put to sleep, scrub areas where the team washes before entering a theatre, recovery bays where patients wake, a sterile store where wrapped packs wait, and a plant room where the air handling kit runs, and the doors round those rooms keep the sterile core shut while the list runs.

  • B3 / C5Grades to LPS 1175 Issue 8.2
  • Coordinator keyOpens every leaf in the suite
  • Sterile coreOperating theatres and sterile store sit inside it
  • Anaesthetic keysOpen anaesthetic rooms only

Seven leaves round a theatre suite: the grade on each leaf

Seven leaves guard a theatre suite, and each leaf takes the grade that fits the room behind it, with B3 on the entrance, the anaesthetic rooms, the scrub areas and the recovery bays, and C5 on the operating theatres, the sterile store and the plant room.

The four leaves that staff and patients pass through in the course of a list hold for three minutes at B3, and the three leaves that guard the theatres, the sterile packs or the air plant hold for five minutes at C5.

Room Grade Period
Entrance B3 FD30
Anaesthetic rooms B3 FD30
Scrub areas B3 FD30
Recovery bays B3 FD30
Operating theatres C5 FD60
Sterile store C5 FD60
Plant room C5 FD60

One report can carry the fire minutes and the forced entry minutes for the same leaf, so the two results sit side by side on the order, and the dual doorset guide shows how fire and forced entry are tested on one leaf.

Entrance leaf where the theatre list begins

Patients arrive for the theatre list through the entrance in small groups through the morning, often on a trolley or in a wheelchair, and the entrance leaf holds B3 for three minutes while the coordinator keeps watch over the way in.

A list change brings one patient in and the last patient out through the same entrance, so the leaf must let a trolley through, hold against a stranger and shut behind each arrival, even when a porter tries to hold it open with a foot. The automatic leaf guide shows leaves that open without a push when both hands are on a trolley.

The coordinator works from the theatre list, so a patient whose name sits on the list for that session passes through, while a visitor with no place on the list waits at the desk until staff come to fetch them. That list keeps the entrance leaf from standing open through the day, because the desk knows who is due and when, and the leaf shuts behind each named arrival.

The front of the suite needs the same care as the leaf itself, because a vehicle that reaches the entrance reaches the patients who wait there for the list, and under ProtectUK the posts stand with a clear gap of 1,200 mm at most and a height of 500 mm at least. The bollard guide shows the posts that stand at the front of the suite.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Anaesthetic room leaves where patients are put to sleep

Patients are put to sleep in the anaesthetic rooms beside each theatre, and the leaves round those rooms take B3 and hold for three minutes, because the drugs and the kit for the next patient sit in the room and the leaf guards them between cases.

Staff wheel a trolley with the patient into the anaesthetic room and out again into the theatre, so the leaf must move under a light hand even when it carries B3. BS 8300 with Approved Document M puts the opening force under 30 N for the first 30 degrees and under 22.5 N after that point.

Anaesthetic room keys open anaesthetic rooms only, and no anaesthetic room key opens the theatres, the sterile store or the plant room, so a key taken from an anaesthetic room opens nothing beyond the anaesthetic rooms. The lock guide shows the cylinder and the handle working as one set, and a 1 star cylinder with a 2 star handle makes a 3 star set under TS 007.

Scrub area leaves between the corridor and the theatre

The team washes at the sinks in the scrub areas before entering a theatre, and the leaves round those areas take B3, because the scrub area sits on the edge of the sterile core and the leaf guards it each time the team passes through with wet hands.

Scrubbed hands must touch nothing on the way into the theatre, so the scrub area leaf opens without a handle pull and shuts behind the team on its own, and the leaf must still hold for three minutes when the scrub area stands empty between cases.

The scrub area leaf must shut fast enough to keep the corridor air out of the sterile core, yet open wide enough for a team member in a gown to pass without brushing the frame, and the closer is set so the leaf meets the frame without a slam that would shake the sinks.

A hospital asks more of its leaves across a whole building than a single theatre suite does, and the hospital door guide shows a building where wards stay full round the clock, while the GP surgery door guide shows a building where patients arrive without a theatre list.

The scrub door is drawn shut after every pass

The scrub door is opened for the team and shut behind them at every pass through the list, so the corridor and the theatre stay apart while the cases run one after another and the list moves from one case to the next. A member of the team pushes through with clean hands, the door swings back, and the closer draws it shut before the next person reaches it.

The closer carries that duty all day. It must draw the door home after a fast push and after a slow one, and it must still pull the door shut when the team is tired near the end of the list. Staff watch the door meet its frame after each pass, and a closer that lets the door hang ajar is written down the same day.

The door is tried before the first case, from the corridor side, with the key worked and the gap looked at beside the frame. The fire door gaps guide shows how the gauge is held against the door and what the reading should be. A gap that runs even at 4 mm tells the team the door sits true in its frame.

Point in the list Door state What staff watch
Before the first case Tried and shut Gap even at 4 mm
Between cases Shut after each pass Closer draws it home
End of the list Shut and checked Latch caught, seal seated

Heat wakes the seal round the door, and it swells to close the gap as the temperature climbs past 200 degrees, finishing its growth before 250. The intumescent seals guide traces the seal from its first warmth to the point where the gap is shut.

After the last case, the scrub door is tried once more

The scrub door is tried once more after the last case, with the latch pulled, the closer watched, and the seal looked at for a seat that runs true round the frame. The list is done, the team has gone, and the door must still stand shut through the night.

One report carries the proof for the door, the frame and the hardware together, because the three were tested as a single set. The report is read before the order is signed, so a door that arrives without its papers is not hung. The fire door certification guide names the papers a report must carry before the door goes up.

The suite is divided into parts that hold fire and smoke apart from each other, and the scrub door draws one line in that division. The fire compartmentation guide traces the line the doors draw through the building from one part to the next.

The lock on the scrub door answers the theatre key and no other key in the suite, so a key lifted from a side room opens nothing at the scrub area. The lock a scrub door must carry is named in the security door locks guide, with its cylinder and handle working as one set.

The suite sends one order for the whole list, and the healthcare doors quote takes each theatre room with its grade and its lock beside it.

Recovery bay leaves where patients wake from anaesthetic

Patients wake from anaesthetic in the recovery bays, and the leaves round those bays take B3 and hold for three minutes, because the bays fill after each case and the leaf guards them again once the bays empty and the patients have moved on to the ward.

Recovery bays are not a hospital ward, because the patients who wake there leave for the ward the same day, and a hospital asks more of its leaves across a whole building. The hospital fire door guide shows a building where patients stay in beds round the clock.

Staff pass through the recovery bay leaves with trolleys and monitors through the list, so a leaf must shut behind each passage and still open under a light hand, and a leaf left open lets noise and draughts reach patients who are waking. A monitor alarm in a bay brings staff through the leaf at once, so the leaf must open fast and shut again behind them.

Operating theatre leaves at the heart of the sterile core

Surgery runs inside the operating theatres, and the leaves round those rooms take C5 and hold for five minutes, because the sterile core sits behind them with controlled drugs and high value kit, and the leaf is the only guard on that core.

Theatres are clean environments, and the sterile core behaves like a cleanroom leaf, with dust kept out and the air held steady while the list runs. The cleanroom door guide shows leaves where dust and damp must stay out of the room behind them.

No published table lines the LPS 1175 grades up with the ASTM ratings, so the order names the LPS 1175 grade on its own, and the LPS 1175 guide sets out the grades behind the order.

Sterile store leaf where wrapped packs and drugs are kept

Wrapped packs, gowns and drugs for the list wait in the sterile store, and its leaf holds C5 for five minutes, because the stock inside is counted and checked and the leaf guards it from the first case until the list ends.

Staff fetch packs from the sterile store at set points in the list, and the leaf shuts behind them each time, so the room is open for minutes at a time and shut for the rest of the day. The steel frame guide shows the frame that carries the leaf and its lock together.

Packs are fetched in the order the list needs them, so the first case takes the top packs and the later cases take the packs behind them, and the leaf shuts each time a pack is lifted out, which keeps the store shut for most of the list.

The theatre coordinator holds the sterile store key with the plant room key, and no anaesthetic room key opens the sterile store, so a key taken from an anaesthetic room opens nothing beyond the anaesthetic rooms. The dental practice door guide shows a smaller healthcare building where medicines sit behind a shut leaf.

The coordinator key is the only key that opens the sterile store leaf

One key in the suite opens the sterile store leaf, and it sits in the pocket of the theatre coordinator from the first case to the last. A key that belongs to an anaesthetic room stops at the anaesthetic rooms, and the store leaf never answers it, so the packs and the drugs behind the leaf are reached only by the hand that runs the list. The coordinator runs the list, so a pack is fetched only when a case on the list calls for it, and the leaf is never opened for a pack nobody asked for.

Staff test the leaf without stepping past its threshold, working the key from the corridor and watching the leaf meet its frame, while the gap beside it is measured with a gauge. The guide to fire door gaps shows how the gauge is held against the leaf and what the reading should be.

Check From What it shows
Key Corridor side Leaf meets its frame
Seal Corridor side Seated and unpainted
Gap Corridor side Even at 4 mm

Heat wakes the seal round the leaf, and it swells to close the gap as the temperature climbs past 200 degrees, finishing its growth before 250. The guide to intumescent seals traces the seal from its first warmth to the point where the gap is shut.

Each case calls for its packs in turn, and the leaf is drawn shut after every fetch, so the store is rarely open and the packs wait behind a shut leaf for most of the list. The leaf that opens for the list and shuts behind it keeps the store shut while the theatre works, and the coordinator knows at any point in the list whether the store stands open or shut.

The lock on the sterile store leaf answers the coordinator key and no other key in the suite, so a key lifted from an anaesthetic room opens nothing in the store. The locks guide names the lock a store leaf must carry and the way its cylinder and handle work as one set.

No pack leaves the store without the leaf shutting behind it

One report carries the proof for the leaf, the frame and the hardware together, because the three were tested as a single set and the report names each piece beside the leaf. The report is read before the order is signed, so a leaf that arrives without its papers is not hung. The guide to fire door certification names the papers a report must carry before the leaf goes up.

Leaf by leaf, the suite is divided into parts that hold fire and smoke apart from each other, and the store leaf draws one line in that division. The guide to fire compartmentation traces the line the leaves draw through the building from one part to the next.

The suite order lists every room with its grade and its lock, and the healthcare doors quote page lists the theatre rooms one by one, so the sterile store leaf and the key that opens it stand on one line together.

Plant room leaf, with the grade, lock and closer on one order line

Pumps, fans and boards that move the air and light the theatres sit in the plant room, and its leaf holds C5 for five minutes, because the air handling plant inside keeps the theatres sterile and the leaf is the only guard on it.

The theatre coordinator key opens every leaf in the suite, while anaesthetic room keys open anaesthetic rooms only, and the master key guide shows how those keys sit together on one suite. The plant room guide shows what that leaf must do.

Every leaf in the suite goes on one list for the order, with a line per leaf naming its room, grade, lock and closer, and each line is read back against its own room before the order is signed. The ten steps guide shows how that list takes shape, and the specifying guide treats the leaf, the frame and the hardware as one doorset.

The grade holds only while the leaf, the frame and the hardware stay as they were tested, and the rating guide shows what keeps an LPS 1175 result valid, while the maintenance checklist shows the routine checks on each leaf, its lock and its closer.

Write the room, the grade, the lock and the closer for every leaf on one list, then check each line against its room before the order goes out.

What grade should an operating theatre entrance door carry?

B3 to LPS 1175 Issue 8.2, a three minute hold, because patients arrive for the theatre list in small groups and the coordinator watches the leaf from the first case to the last.

What grade should an operating theatre door carry?

C5 to LPS 1175 Issue 8.2, a five minute hold, because the sterile core behind that leaf holds controlled drugs and high value kit.

What grade should a sterile store door carry?

C5 to LPS 1175 Issue 8.2, a five minute hold, because the wrapped packs and drugs for the list are counted and checked behind that leaf.

Can an operating theatre leaf hold a fire period and a security grade?

Yes, an operating theatre leaf can be proved for fire and for forced entry together, and the two results stand side by side in one report.

Who holds the keys in an operating theatre suite?

The theatre coordinator holds the key that opens every leaf, while anaesthetic room keys open anaesthetic rooms only.

Specifying security doors for operating theatres?Send the room list with the grade each leaf must hold, and ask for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →