ArxBridge
Restaurant Security Doors
A restaurant runs on doors that guard the kitchen, the stock room and the back door, so each leaf takes the grade the room behind it demands.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A restaurant is a kitchen, a stock room and a dining room under one roof, and the doors between them decide what stays where it belongs. The kitchen holds the heat and the knives, the stock room holds the takings, and the dining room holds the guests, so a door between one part and the next must hold the line between them.
The grade on a restaurant door is LPS 1175, and the category follows the room behind the leaf. Under Issue 8.2, dated September 2024, the three categories hold three, five and ten minutes: B3, C5 and D10 in that order. The dining room takes the lowest grade of the three, the stock room takes a higher one, and the room that holds the takings takes the highest.
The rules for the dining room and the kitchen are set out in the fire door regulations restaurants guide, and the rules for the shared parts of a shop are set out in the fire door regulations retail guide. The restaurant order names every door in the building, with the grade and the lock beside each one, so the door that arrives is the door the room needs.
- LPS 1175 B3 / C5 / D10Forced entry grades to Issue 8.2
- Kitchens and stock roomsWhere the grade rises
- FD30 / FD60Fire periods to EN 1634-1
- One listEvery restaurant door named
The kitchen, the stock room and the back door: one restaurant, three grades
A restaurant splits into three parts, and the grade follows what each part holds. The kitchen feeds the dining room, the stock room feeds the kitchen, and the back door feeds them both from the street, so each part takes the doors its work demands.
The kitchen takes the doors the cooks pass through all day, and each leaf must open for a cook with their hands full and shut behind them without a hand on it. The stock room takes the doors the public never sees, and each leaf must hold against the attack the takings behind it invite.
The schedule is written before the order goes out, with every opening on it and the grade beside each one. A leaf ordered without a line on the schedule may land in the wrong room, and a leaf in the wrong room guards the wrong thing.
The kitchen door: the leaf that takes heat, steam and trolleys
The kitchen door takes the cooks in and out through the whole service, and it takes trolleys loaded with plates, so the leaf must swing free and shut behind each one without a slam. The leaf takes heat and steam on one side and the cool of the dining room on the other, and the seals must hold their line through both.
The kitchen leaf takes a closer that pulls it home after every cook who passes, because a leaf left standing open is a fire door that holds nothing. The closer is set to pull the leaf shut without a slam, and it is tested by opening the leaf and watching it shut on its own. The fire door closers guide works through the sizes and the fitting of closers.
The pass beside the kitchen takes a hatch of its own, and the hatch takes a leaf with a lock that holds it shut when the restaurant is closed.
The stock room and the cellar: where the takings wait
The stock room holds the wine, the spirits and the goods the kitchen will need next, and the leaf that guards it takes the grade the value behind it demands.
The cellar takes the same care, because the room below the restaurant holds what the bar runs on. A cellar leaf takes a lock the staff control, and the leaf, the frame and the lock are proved together as one doorset, with the report naming each one. What breaks a rating once a door is fitted is named in the keeping an LPS 1175 rating valid guide.
The stock room lock takes the grade the room behind the leaf demands, and the security door locks guide covers the lock the key turns. A shopfront takes the same care with its stores, and the retail security doors guide sets out the doors a shop needs.
The back door: the leaf the public never sees
The back door takes the deliveries in from the street, and it takes a leaf wide enough for trolleys and a closer that pulls it shut after each load.
The back door takes the highest grade on the order after the stock room, because the leaf that faces the street is the leaf an intruder tries first. The leaf, the frame, the fixings and the lock are proved together as one doorset, and the report names the grade the leaf holds.
A bin store leaf takes the same grade as the back door beside it, and the lock on it takes the same key as the kitchen. The doors that guard a hotel take the same care with their kitchens, as the hotel security doors guide shows.
Fire and forced entry on the same leaf
A restaurant leaf can carry both proofs at once, because the kitchen needs fire held back and the stock room needs an intruder held out. The fire side is proved to EN 1634-1 in E, EW and EI from 30 to 120 minutes, and the forced entry side is proved to LPS 1175. Both proofs sit on the same leaf, frame and seals, proved together as one doorset, so the order names one doorset for both jobs. The fire and security doors dual certification guide works through how two proofs share one doorset.
The period follows the room behind the leaf, because the kitchen, the stock room and the dining room ask different things of the leaf, and the grade follows the value behind it. The period runs 30 to 120 minutes, and the letters beside the number name what was held back: flames alone, flames with some heat, or flames with the heat as well. The route doors take smoke seals to BS EN 1634-3, Sa for smoke at room temperature and S200 for smoke at 200 degrees. How smoke is held back while people move past is covered in the smoke control doors guide.
Keep the gap round the leaf at 4 mm, so the leaf swings free and the seal meets the frame all round. The intumescent seal swells when the heat reaches around 200 to 250 degrees, closing the gap the leaf leaves.
The front door and the dining room: the leaves guests meet
The front door is the leaf every guest passes, and it must open for a guest with their hands full and shut behind them without a hand on it.
The glass in the front leaf takes the same proof as the leaf beside it, because a leaf that holds while its pane fails has held nothing. The bead and the fixings that hold the pane are the ones named in the test report. What the glass itself costs is worked through in the fire rated glass cost guide.
The dining room doors take a panic bar to BS EN 1125, running across at least 60 percent of the leaf, so one push throws the latch for a crowd. The force to open a leaf on the way out stays below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M.
Locks, codes and the pass: who opens which door
The staff route through a restaurant runs from the front door through the dining room to the kitchen and back, and each leaf on the route opens for staff and stays shut for the public. Each leaf on the route takes a reader beside it, and the list behind the readers decides which fob opens which door. The lock the key turns is covered in the fire door hardware guide.
The pass between the kitchen and the dining room takes a leaf that opens for a cook with a plate in each hand and shuts behind them, and the lock on it takes a code the staff share. Readers, releases and wiring beside a leaf are covered in the door entry systems guide.
Each leaf is given its answer before the order goes out: what it does when the power fails. The answer is written beside each door on the order, so no leaf is left to guess on the night it matters.
The restaurant order: every leaf on one list
The restaurant order is written as one list, with a line for every door in the building and the leaf, the grade, the lock and the closer beside each one, so the door that arrives is the door the kitchen, the stock room and the back door need. A list that names one leaf for the whole restaurant leaves the fitter guessing which room takes which grade, and a leaf in the wrong room guards the wrong thing.
The price comes off the same list the order is built from, with every leaf, lock, closer and seal given its own line before the order goes out, so the kitchen, the stock room and the back door are all priced before the fitter is booked. The how to specify security doors guide sets out the columns the list needs, and what each step up the scale adds to the price is worked through in the security door cost factors guide.
The restaurant is checked while it is running, so the manager tries each leaf between services: the kitchen door after the lunch rush, the stock room door before the delivery arrives, and the back door at closing. A leaf that drags, a closer that has lost its pull, or a seal that has come away from its groove is written beside the door it belongs to, with the part and the day it was found. The checks a visit should cover are set out in the fire door inspection checklist, and the doors that must hold both fire and forced entry are covered in the security door maintenance checklist.
| Position | Door | Grade | What to check |
|---|---|---|---|
| Front door | Glazed leaf | LPS 1175 B3 | Leaf, glass, reader |
| Kitchen | Fire leaf | FD30 | Leaf, closer, seals |
| Stock room | Steel leaf | LPS 1175 C5 | Leaf, lock, seals |
| Cellar | Steel leaf | LPS 1175 C5 | Leaf, lock, closer |
| Back door | Steel leaf | LPS 1175 B3 | Leaf, closer, lock |
A restaurant door holds only as long as the kitchen behind it and the stock room beside it, so the grade, the period and the lock must all sit on the same list.
What grade should a restaurant door carry?
The grade follows the room behind the leaf: B3, C5 or D10 to LPS 1175, with the stock room taking a higher category than the dining room beside it.
Can one leaf hold fire and forced entry?
Yes, when the leaf, the frame and the seals faced both tests together, so the one doorset carries the proof for fire and for forced entry.
Do restaurant doors need access control?
The doors behind the dining room take a reader beside the leaf, so the leaf opens for staff and stays shut for the public.
What period should a kitchen door carry?
The period follows the room: FD30 or FD60 to EN 1634-1, and the letters beside the minutes name what the doorset held back, flames alone or flames with the heat.
Who checks the restaurant doors?
The manager walks the round that covers every door, and the record of each visit stays with the restaurant file.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.