Fire Door Rules for Bowling Alleys
A bowling alley fills with a late-night crowd, so each door takes the fire period its room demands, FD30 on the route out, FD60 behind the desk.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A bowling alley fills with a late-night crowd, and the fire rules for the building follow the rooms behind each leaf. The entrance, the cash desk and the lane hall take FD30, and the back office, the plant room and the cash counting room take FD60, because the rooms behind the desk hold the bookings, the plant and the takings, and those rooms ask for a longer hold than the route out.
The number beside FD is a count of minutes, and the count comes from EN 1634-1, which runs from 30 to 120. E marks a leaf that held flame alone, EW marks a leaf that held flame with part of the heat, and EI marks a leaf that held flame and heat together, so the count names the minutes and the letter names what was held back.
A bowling alley follows the same fire rules as any other building that fills with a crowd late at night, and the leaf on each room takes its period from what sits behind it and from how fast the people behind it can move. The fire door regulations cinemas guide covers the fire rules for a building that seats a crowd in the dark, and the fire door regulations leisure centres guide covers the rooms of a building that holds pools and sports halls, while the leaves in a bowling alley follow the lanes and the counting room behind them.
- FD30 / FD60Fire periods to EN 1634-1
- Lane hallWhere FD30 holds the hall clear
- Sa / S200Smoke ratings to BS EN 1634-3
- One listEvery alley door named
Six rooms in a bowling alley: the period each leaf takes
Six rooms make up a bowling alley, and the period follows what each room holds. Bowlers come in through the entrance, pay at the cash desk, play in the lane hall, and the back office keeps the bookings and the float, the plant room keeps the pinsetters running, and the cash counting room keeps the takings.
FD60 sits on the back office, the plant room and the cash counting room, because the bookings, the boards and the takings behind those leaves need sixty minutes before flame reaches them. FD30 sits on the entrance, the cash desk and the lane hall, because the people on that route are out in far less time than thirty minutes.
Every opening takes a line of its own on the order, with the leaf and the period written beside it, so no leaf is hung on guesswork. The table names the six rooms, the period each one takes and the grade beside the period, so the fitter checks each leaf against its own line as it is hung.
| Room | Period | Grade | What to check |
|---|---|---|---|
| Entrance | FD30 | B3 | Leaf, glass, closer |
| Cash desk | FD30 | B3 | Leaf, glass, closer |
| Lane hall | FD30 | B3 | Leaf, glass, closer |
| Back office | FD60 | C5 | Leaf, lock, seals |
| Plant room | FD60 | C5 | Leaf, lock, seals |
| Cash counting room | FD60 | D10 | Leaf, lock, seals |
What FD30 and FD60 hold back on a night of bowling
The minutes in a fire period are the minutes the doorset earned in the test, and the doorset is the leaf, the frame, the fixings and the lock proved as one. The report states the period the doorset holds, and the order puts that period beside the leaf. What the report behind a period must hold is named in the fire door certification guide.
A leaf in the alley may need to hold fire as well as forced entry, and one doorset carries both proofs in a single report. EN 1634-1 gives the fire minutes, LPS 1175 Issue 8.2 of September 2024 gives the forced entry grade in B3, C5 and D10, and the fire and security doors dual certification guide shows the pair proved on the same leaf.
FD60 on the back office, plant room and cash counting room
Behind the back office leaf sit the bookings, the float and the papers that record the night, so the leaf takes FD60 and stays shut whenever no one is working inside. Sixty minutes is the hold the room asks for, because flame that reaches it takes the bookings and the float.
The plant room holds the boards and the equipment that keep the pinsetters, the lights and the air moving, and its leaf takes FD60 because the boards behind it feed the whole alley. Leaves of a plant room are covered in full in the plant room fire doors guide.
Behind the counting room leaf sit the takings, so the leaf takes FD60 and stays shut and locked whenever no one is counting inside. The counting room leaf is shut each time the last person leaves the room, because an open leaf holds back no flame at all.
The lane hall: FD30 to hold the hall clear
Bowlers in the lane hall move slowly when the alarm sounds, because they carry shoes and bags and some of them have never used the building, so the hall leaf takes FD30 to hold the hall clear while staff reach the lanes. Thirty minutes is more than staff need to clear a hall of bowlers, and the leaf gives them that time with the lanes still clear of flame.
Staff see the lanes through a glazed panel in the hall leaf, so the leaf stays shut while the bowlers are watched, and the pane is proved with the leaf round it, the glass, the bead and the fixings named together in the report. The fire door vision panels guide names the panels a fire leaf may carry, and the steel vs timber fire doors guide puts the two leaf materials beside each other.
FD30 sits on the hall leaf beside the grade the room demands, and the hardware on the leaf was proved with the leaf, so no fitting takes the period off it once it is hung.
Entrance and cash desk: FD30 on the route the crowd uses
Both the cash desk leaf and the entrance leaf take FD30, because bowlers pass through them on the way out. Half an hour is more than the people on that route need to leave, and the route behind the leaves is short, with the street at the end of it.
Where the route serves a crowd of more than 60 people, the leaves on the way out carry a push bar proved to BS EN 1125, and the bar spans at least 60 percent of the leaf width. A bowler reaching the leaf with a crowd behind them opens it with one push, and the bar works with the supply to the building on or off. What the bar must do when people push against the leaf is set out in the panic hardware guide, and the emergency exit doors guide covers the leaves on the way out.
The alarm may sound while bowlers who have never used the building sit in the hall, so the route to the street is signed at every turn. Nothing stands on the route. A leaf on the way out must still open to a push from a bowler carrying shoes and a bag, and BS 8300 with Approved Document M puts the push below 30 N through the first 30 degrees of swing and below 22.5 N beyond that.
Smoke on the lanes: Sa and S200 beside the period
Bowlers leaving the hall meet smoke before flame, so the leaves on the way out carry a smoke rating beside their fire period. BS EN 1634-3 names the two smoke ratings, Sa for smoke at room temperature and S200 for smoke at 200 degrees. How the route leaves keep the smoke back while the bowlers move past them is worked through in the smoke control doors guide.
A leaf that must stay open while the alley is busy is held by a device proved to BS EN 1155, and the device lets the leaf go by itself the moment the alarm sounds. The fire compartmentation guide names how the leaves hold the line between one part of the alley and the next, and a wedge under a leaf gives it no period at all while it stands open, so the wedge is never the device that holds a fire leaf.
Closers, seals and gaps on bowling alley doors: what the period rests on
A FD60 leaf gives its hour only when the closer shuts it, the seals meet the frame and the gaps stay narrow, because flame passes through a leaf left ajar in seconds and through a wide gap soon after. BS EN 1154 proves the closer, and EN 1 is the smallest power size it names, while EN 3 is the minimum a fire door takes.
The seal round the leaf swells shut when the heat round the frame climbs to 200 to 250 degrees, so flame and hot gas cannot pass the gap. The gap round a hung leaf measures 4 mm, and a gauge used on the monthly walk shows whether a gap has grown past that figure. Fitting the seal is covered in the intumescent seals guide, what the closer must do is covered in the fire door closers guide, and measuring the gaps is covered in the fire door gaps guide.
A fire leaf hangs on hinges proved to BS EN 1935, grade 13 proved through 200,000 cycles with a leaf of 120 kg and grade 14 proved through 200,000 cycles with a leaf of 160 kg, so the hinge matches the weight of the leaf it carries. The fire door signage guide names what each sign on a fire door must say.
The bowling alley fire door order: every leaf, its period and its proof
One list carries the whole bowling alley fire door order, with a line for every opening that names the leaf, the period, the lock and the closer beside it. One leaf named for the whole alley leaves the fitter to guess.
The order is checked leaf by leaf before anyone signs it, because a closer that turns up after the doorset holds the whole job up, and a leaf with no line beside it cannot be checked when it arrives. The how to specify security doors guide names what the order must hold for every door.
The duty manager takes the door list round the alley each month and works each leaf in turn. A leaf that drags, a closer that leaves the leaf standing open or a seal that has been painted over is written beside its own door the day it is found, so the fault is put right before the leaf is asked to hold. The fire door inspection checklist sets out what to look for on each leaf, and the fire door maintenance guide covers the work that keeps the leaves holding.
The period on a bowling alley leaf follows the room behind it, so FD60 and FD30 must sit on the same list as the grade and the lock for each leaf.
What period should a bowling alley counting room door carry?
FD60 to EN 1634-1, because the takings sit behind the counting room leaf, and sixty minutes is the hold that room asks for.
What period should a lane hall door carry?
FD30 to EN 1634-1, because the hall leaf holds the lanes clear while staff reach the bowlers, and half an hour is the hold that room demands.
Can one leaf hold fire and forced entry?
Yes, where a single leaf went through both tests, so one report names the period and the grade together.
Do bowling alley fire doors need a smoke rating?
Yes, Sa or S200 to BS EN 1634-3 sits beside the period on the leaves of the way out, because smoke reaches the bowlers leaving before flame does.
What happens when a fire door will not shut?
A leaf that will not shut is written beside its own door the day the fault is found, and the alley does not wait for the next look round before the leaf is put right.