A gym is a building that never really closes. Members arrive before work and leave late at night, and the doors must open for every one of them.
Each door in a gym takes its grade from the room behind it, because the entrance, the changing room and the stock room ask different things of the leaf. The order names the grade beside each opening, so the door that arrives is the door the room needs.
The doors for a public leisure building are worked through in the leisure centre security doors guide, and the doors that guard each part of a building are covered in the types of security doors guide.
- B3 / C5 / D10LPS 1175 grades to Issue 8.2
- 3, 5 and 10 minutesWhat each grade holds
- One scheduleEvery gym door named
- Fail safe or fail secureWhat each leaf does without power
The entrance: the door every member walks through
The entrance leaf is the hardest working door in the gym. It opens for the member with a bag in one hand and a bottle in the other, and it shuts behind each one without a hand on the leaf. A leaf that will not shut leaves the front of the building open to the street.
A glazed entrance leaf lets the staff at the desk see who stands outside before the leaf opens, and it lets light into the foyer through the day. The pane beside the leaf takes the same proof as the leaf itself, because the leaf and the glass are proved as one doorset.
The reader beside the entrance decides who walks in. A member fob opens the leaf, a staff fob opens the leaf and the rooms behind it, and a fob that has been lost opens nothing until it is taken off the list. The door entry systems guide covers the readers, the releases and the wiring that sit beside a leaf.
Changing rooms and lockers: the doors members trust
A changing room door is trusted with more than the room behind it. Members leave their clothes, their bags and their phones on the far side of the leaf, so the lock must hold from the inside while the room is in use and open for the staff when the room stands empty. The lock the key turns is covered in the security door locks guide.
The corridor between the changing rooms and the gym floor takes doors that stand open through the day and shut at night. A leaf that must stand open takes a hold-open device proved to BS EN 1155, so the leaf shuts on its own when the alarm sounds. A leaf wedged open with a bin holds nothing back when the fire comes.
Steam and damp sit in the air of a changing room from the first shower of the morning, and the leaf, its fixings and its seals take that damp day after day. The specification names a leaf that holds its line where the air stays wet, because a leaf that swells leaves a gap the smoke can use.
The stock room and the office: where the grade rises
The stock room holds the supplements, the merchandise and the kit the gym sells, and the leaf that guards it takes a higher grade than the leaf beside it that guards a corridor. The forced entry proof on a gym door is LPS 1175, and the category follows the room behind the leaf. Under Issue 8.2, dated September 2024, B3 resists for three minutes, C5 for five and D10 for ten, and the category on the order is set by what sits behind the leaf.
The office takes the highest grade on the order, because the room behind it holds the member records, the contracts and the takings. A leaf that guards the takings takes D10, because it must hold longest, while the stock room beside it takes C5 and the changing rooms take B3. The LPS 1175 vs PAS 24 guide works through the two ratings side by side.
Before Issue 8 the same three categories went by the names SR2, SR3 and SR4, and the order carries the name the product was proved under. The order names LPS 1175 on its own, because no published table turns its categories into any other standard’s ratings.
Access control in a gym: fobs, codes and the front desk
Access control in a gym is a list, and the list decides which fob opens which door. The member fob opens the entrance and the changing rooms, and the staff fob opens the stock room and the office as well. A list that gives every fob every door gives the stock room to anyone with a membership.
The turnstile at the front takes the members who have paid and turns away the ones who have not, and the leaf beside it takes the members who cannot pass through the turnstile. The security turnstiles guide covers the gates that count people in and out.
What each leaf does when the power fails is settled door by door before the order goes out. The entrance leaf opens when the power fails, because the members inside must reach the way out, while the leaf that guards the stock room and the office stays shut, because the rooms behind them must stay guarded. That answer decides what the leaf does in a blackout, so it is written on the order beside each door.
Glass, light and the view in: glazed leaves at the front
A gym sells its light and its view, and the glazed leaves at the front carry both. The pane lets a passer-by see the floor in use, and it lets the staff at the desk see the street, so the leaf must hold its proof while letting the light through. The glass in the leaf takes the bead and the fixings the test report names, and the frame beside it takes the same proof as the leaf.
A vision panel on a studio door lets the instructor see the class without opening the leaf, and it lets a member see whether the class has started before the leaf opens. The pane in the leaf takes the same proof as the leaf itself, because a leaf that holds while the pane beside it fails has held nothing. The fire rated glass cost guide works through the cost of the glass itself.
The glass beside the entrance takes the same care as the glass in the leaf. A sidelight or a fanlight beside the leaf takes the proof the leaf carries, because the wall beside a proved leaf must hold as long as the leaf does.
| Position | Door | Grade | What to check |
|---|---|---|---|
| Entrance | Glazed leaf | LPS 1175 B3 | Leaf, glass, reader |
| Changing room | Timber leaf | LPS 1175 B3 | Leaf, lock, seals |
| Stock room | Steel leaf | LPS 1175 C5 | Leaf, lock, seals |
| Office | Steel leaf | LPS 1175 D10 | Leaf, lock, reader |
| Plant room | Steel leaf | LPS 1175 C5 | Leaf, seals, gap |
Noise, sweat and steam: the parts a gym wears out first
Every member who passes through a gym door pulls the closer through its cycle, and the leaf has to settle shut without a slam. BS EN 1154 sets EN 3 as the smallest power a fire door closer may carry, and the fitting is proved by opening the leaf and seeing it come home on its own. Sizes and fitting are worked through in the fire door closers guide.
Keep the gap round the leaf to 4 mm. The leaf must swing free, and the seal must meet the frame all round when the leaf shuts. The intumescent seal swells in heat at around 200 to 250 degrees, so paint over it is a fault: the seal cannot swell through paint. A seal that has come away from its groove, or a gap that has opened since the last visit, goes into the record beside the door on the day it is found.
The hinges hold the leaf square in its frame, and they take the weight of every swing. A hinge that loosens lets the leaf settle lower month by month, and the leaf begins to drag before anyone notices the gap above it has grown. The round tries each hinge in turn, and a hinge that has worked loose is tightened before the leaf drops far enough to drag. The doors that must hold both fire and forced entry are covered in the fire and security doors dual certification guide.
Fire and forced entry on one leaf
One gym leaf can hold fire and forced entry together, because the room behind it needs both proofs at once. EN 1634-1 proves the fire side in E, EW and EI from 30 to 120 minutes, and LPS 1175 proves the forced entry side in B3, C5 and D10, three, five and ten minutes. Each proof is run on the same leaf, frame and seals together, so the one doorset carries the report for both.
The doors on the way out take a panic bar to BS EN 1125, at least 60 percent of the leaf wide, so the leaf opens for a crowd with one push. The force to open a door on the route stays below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M. The panic hardware guide covers the bars and the pads that throw the latch.
Sa and S200 are the smoke seals on the route doors, proved to BS EN 1634-3: Sa for smoke at room temperature, S200 for smoke at 200 degrees. The seal closes the gap the leaf leaves behind it, and it must sit against the frame all round, because the smoke is on the route before the flames arrive. The doors that hold smoke back while people move past them are covered in the smoke control doors guide.
The gym door list: every leaf named before the order
Put the gym door order together as one list, with a line for every door and the leaf, the grade, the lock and the closer beside each one, so the door that arrives matches the door that was ordered. A list that names one leaf for the whole gym leaves the fitter to guess which room takes which rating, and a leaf fitted to the wrong room guards the wrong thing.
The price is worked out from the list, line by line, so every leaf, lock, closer and seal is priced before the order goes out. The how to specify security doors guide sets out the columns the list needs.
The doors are walked in turn, from the entrance through the changing rooms to the stock room and the plant room, and each leaf is opened and shut as the round reaches it. A fault is noted where it is found, with the door, the part and the date beside it, and the repair is ordered while the fault is still small. The fire door inspection checklist names what each visit should look for.
A gym door holds only as long as the grade on its leaf and the closer that pulls it home, so the grade, the reader and the closer must all sit on the same list.
What grade should a gym entrance door carry?
The grade follows the room behind the leaf: B3, C5 or D10 to LPS 1175, with the entrance taking B3 and the rooms that hold the takings taking a higher category.
Can one leaf hold fire and forced entry?
Yes, when the same doorset is proved for fire and for forced entry together, so one leaf carries both proofs at once.
Do gym doors need access control?
The entrance takes a reader so only members and staff walk in, and the list behind the reader decides which fob opens the stock room and the office.
What happens when the power fails?
The leaf on the way out opens when the power fails, because the members inside must reach the way out, while the leaf that guards the stock room stays shut.
Who checks the gym doors?