Certified physical security

ArxBridge
Steel door sample in a security test frame with an assessor in a UK test laboratory

ArxBridge

Laboratory Security Doors

Laboratory door rules: rated doorsets that seal rooms and resist attack for research and testing sites, with access control and one schedule for the whole site.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A laboratory holds samples, equipment and records that cannot be replaced, and the doors on its rooms decide who reaches them and what leaves with them. Research rooms, stores and corridors sit side by side, so a door that seals one room and a door that resists attack on the next both belong on the same schedule.

The order starts with the room, not with the leaf. A store of solvents faces a different risk from a room of instruments, and a corridor that moves staff between the two faces a different risk again, so the rating follows the opening.

The rating, the sealing, the access control and the records all sit inside one schedule, and an order that names each one plainly puts the right doorset on the right opening. The columns for that schedule are set out in our how to specify security doors guide, and the zone-by-zone discipline is worked through in our data centre physical security guide.

  • LPS 1175 B3 / C5 / D10Forced entry ratings, three, five and ten minutes
  • LPS 2081 SRA / SRBStealth ratings, one and three minutes
  • PAS 24Enhanced security doorset
  • FD30S30 minutes with a smoke seal tested to BS EN 1634-3

Research rooms, stores and corridors: where a laboratory puts its doors

A laboratory divides into rooms that hold different things: research rooms where the work happens, stores where samples and solvents sit, and corridors that move staff between them. Each room asks for its doors in a different place, and the rating follows what sits behind the door.

The research room door works all day. Staff pass through it with samples, instruments and records, so it has to open quickly for the right hands and hold against the wrong ones, and a door that fails at either duty leaves the work inside open to the corridor.

Start with a walk round the site, and note every door a person can reach from outside. The rating for each door follows the attack it could face, so a staffed entrance takes less than a rear door onto a yard nobody watches after dark. Our security door specification mistakes guide covers the errors that leave a rating short of the opening.

The rating that fits the room: B3, C5 and D10 door by door

The LPS 1175 rating on a laboratory door comes from two facts: the tools the doorset resists and the minutes it holds. Three minutes against the category B tool set gives B3, five minutes against the category C tool set gives C5, and ten minutes against the category D tool set gives D10. Issue 8.2, dated September 2024, carries the current labels, and older drawings still show SR2, SR3 and SR4, which read as B3, C5 and D10.

A research room usually takes B3, a sample store C5, and a store of controlled substances D10, but the risk assessment sets the rating for each opening, not the habit of the last order. The rating tables sit on the LPS 1175 page, and the two routes are weighed in our LPS 1175 versus PAS 24 guide.

PAS 24 and EN 1627 offer two different routes to a rated doorset: PAS 24 is the enhanced security doorset, and EN 1627 grades from RC1 to RC6. Each route is proved by its own test, so the order must name the route it means, not the other one. The two scales are compared in our LPS 1175 vs EN 1627 guide.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Sealing the room: air, dust and the door that must shut tight

Some laboratory rooms must hold their air inside. A room that works with powders, solvents or cultures needs a door that shuts tight and stays shut, because a gap round the leaf lets the room leak into the corridor and the corridor leak into the room. The seals and the closer belong on the schedule beside the rating, because a door that stands open seals nothing.

The seal works only where the gap round the leaf is right, so the gap stays at 4 mm, and the intumescent seal swells as the heat builds, closing the gap at around 200 to 250 degrees. Where the seal is missing, painted over or cut short, the gap it leaves lets fire and smoke through whatever the rating on the leaf says.

A door that must seal and resist attack at once needs both proofs on the same assembly. The frame, the seals and the fixings all carry the rating, so the order names the whole doorset, not the leaf alone. How glass, frame and beads are tested together is covered in our fire rated windows guide, and the duties of a door on a smoke path are covered in our smoke control doors guide.

The seal that keeps the room shut: air, dust and the leaf

A laboratory door must shut tight, because the room behind it holds samples and instruments that dust and draughts can spoil. The seal round the leaf matters as much as the lock, and a gap round the leaf lets air through whatever the rating on the leaf says.

The gap round a fire door leaf must stay at 4 mm, because a wider gap lets fire and smoke past the leaf. Intumescent seals expand at around 200 to 250 degrees, and the seal must be checked on every round, because a seal that has come away or been painted over leaves the gap open.

A leaf can only seal as well as the frame it closes into, so the frame needs its own seals and its own check on every round. Order the frame, the leaf and the hardware as one doorset, and ask for the test report that names all three, because a report that names only the leaf says nothing about the frame it closes into.

Research rooms, stores and corridors each ask for a different door, and the rating follows the room. LPS 1175 grades forced entry in minutes, with B3 holding three minutes, C5 holding five minutes and D10 holding ten minutes, all under Issue 8.2, dated September 2024. The grades in full are set out on our LPS 1175 page.

Glazing lets staff see into the room without opening the door, and the glass must be proved for the job. The glass, the frame and the fixings belong on the same line, because a pane in the wrong frame carries no proof at all. The windows that share the same wall are covered in our fire rated windows guide.

The laboratory that empties at night: stealth beside forced entry

When the last member of staff leaves, the laboratory stands empty until morning, and the doors must hold through those hours without anyone to hear a forced entry. A thief who works without noise needs time, and the rating must give the alarm time to answer.

LPS 2081 grades doors that must resist a stealth attack, with SRA holding one minute and SRB holding three minutes. The stealth grade sits beside the forced entry grade on the same schedule line, and the test report must name both grades and the doorset they were proved on.

Access control keeps the laboratory doors together, so one card opens the rooms a member of staff uses and one stopped card stops working everywhere at once. Contractors and visitors take a card that ends at the end of the day, and the record should name who holds each card.

Fire and forced entry share the laboratory door where the room needs both. A door that must hold fire takes FD30 or FD60 proved to EN 1634-1, and the two proofs sit on separate lines because each is proved on its own test. How the two proofs sit together is worked through in our fire and security doors dual certification guide.

Room Rating Sealing Evidence
Research room LPS 1175 B3 Seals, 4 mm gaps Test report names the doorset
Store LPS 1175 C5 Seals, 4 mm gaps Test report names the doorset
Corridor LPS 1175 B3 Seals, closer Test report names the doorset
Night store LPS 2081 SRB Seals, reader Test report names the doorset

Put the rating, the sealing and the stealth grade on one schedule line for every room, so the next reader can see what was tested and what holds it. The checks each round should make are set out in our security door maintenance checklist.

The quiet attack: LPS 2081 in a laboratory that empties at night

After hours, the attack on a laboratory changes. LPS 2081 proves a doorset against a quiet attack, SRA for one minute and SRB for three, and the minutes follow the site: a room under camera watch gives the attacker little time, while a store nobody watches gives the attack longer to work.

Stealth and forced entry are two different proofs, and a door that needs both must carry both ratings on the same line. A store door that holds against a quiet attack but falls to a crowbar in three minutes has only half a rating, so the schedule names both proofs for every door that stands empty overnight.

Access control for staff, contractors and visitors

Access control on a laboratory door decides who can open which room, and when. Staff take a card or a fob for the rooms they use every day, contractors take a code that dies when the job ends, and visitors take the intercom, because a visitor with no card has no other way in.

A door that locks shut when the power fails traps people inside, so the release on power failure belongs in the specification beside the reader. The release must work when the power is gone as well as when the alarm sounds, and a battery backup or a manual release belongs on the schedule beside the motor.

A card that is lost should stop working everywhere at once, so one lost card never opens every room in the building. The office that issues the cards should be able to stop one card without stopping the rest, and the record should show which card opened which door and when. Readers, fobs and biometrics in the lane are covered in our security turnstiles guide.

Fire and security on one doorset: the two proofs together

A laboratory door often has to do two jobs at once, and each job needs its own test report. The fire report comes from EN 1634-1 and the forced entry report from LPS 1175 or PAS 24, and a report that names only the leaf leaves the frame, the seals and the fixings unproved.

A laboratory door on an escape route usually takes FD30, a door in a compartment wall usually takes FD60, and a door on a smoke path takes FD30S, with a smoke seal proved to BS EN 1634-3. Closers to BS EN 1154 must pull the leaf shut every time, with no fire door taking less than EN 3, and a closer set too strong puts the door outside the access rules, because BS 8300 and Approved Document M cap the opening force at below 30 N through the first 30 degrees and below 22.5 N beyond that.

Hinges to BS EN 1935 carry the leaf through its life: grade 13 is proved for 200,000 cycles at 120 kg, and grade 14 for the same cycles at 160 kg. A hinge that cannot carry the leaf lets it drop over time, until the leaf drags on the floor and the latch no longer meets the keep. For the grades and the parts behind a working fire door, see our fire door hardware guide.

Glazing and vision panels: seeing into the room without opening it

A vision panel lets staff see into a laboratory before they open the door, and the glass in it must hold if a fire starts inside. The pane, the frame, the beads and the fixings are tested as one assembly, so a rated pane set in a frame that was never tested with it has no rating at all.

Impact resistance is proved to EN 356, which grades a pane from P1A to P8B, with the top three classes set by axe blows: 30 to 50 for P6B, 51 to 70 for P7B, and 70 or more for P8B. A pane that must hold fire and resist impact needs a test report for each job, and the order names both classes on the same line.

Where the work behind the glass must stay unseen, the panel takes frosted or wired glass, but the rating stays the same. How the assembly is proved is explained on the fire rated glazed doors page, and how glass, frame and beads are tested together is covered in our fire rated windows guide.

The laboratory order: one schedule for every room

Set the enquiry out as a specification, one line for every laboratory door. Each line names the room and the position, the forced entry rating, the stealth rating where one is needed, the fire period and the smoke seal, and the leaf, frame, glass, seals and hardware as one doorset. A rating that sits on the leaf alone is no rating at all: ask for it on the whole doorset, proved to LPS 1175 or PAS 24.

Keep the test report, the classification and the hardware schedule with the doors from the day they arrive, and write the inspection routine into the handover pack, so the next team can see which door carries which rating and which check each door has passed. What each check looks for is set out in the fire door inspection checklist.

Room Door Rating What to check
Research room Swing security door LPS 1175 B3 Closer, reader, seals
Sample store Security door LPS 1175 C5 Lock, closer, seals
Solvent store Security door LPS 1175 D10 Lock, seals, self-closing
Corridor cross-door Fire door FD30S Seals, gaps, latch
Plant room Security door LPS 1175 B3 Closer, hinges, seals

A laboratory door seals the room behind it and resists the attack in front of it, so the rating, the seal and the access control must all sit on the same schedule.

What security rating do laboratory doors need?

The site decides, by the room and what sits behind the door. A research room often takes B3, a sample store C5, and a store of controlled substances D10, and the risk assessment names the rating for each door.

Do laboratory doors need to seal?

Where the room must hold its air inside, yes. The seals and the closer belong on the schedule beside the rating, because a door that stands open seals nothing, and the gap round the leaf stays at 4 mm on a fire door.

Can one laboratory doorset hold a fire rating and a security rating?

Yes, where the doorset is proved for both jobs at once. Fire is proved to EN 1634-1 and forced entry to LPS 1175 or PAS 24, and each proof must name the doorset that will be fitted.

What breaks a laboratory door rating?

A seal that has come away, a hinge that drops, a closer that cannot shut the leaf, or a lock that gives way before the leaf. Repair or replace it, and record the work.

How often should laboratory doors be checked?

Each door is checked on the routine the risk assessment sets, and the record names the door, the fault and the fix. The inspection checklist guide sets out what each check looks for.

Specifying security doors for a laboratory?Send the door schedule and the site plan for a tested doorset quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?