Certified physical security

ArxBridge
Steel door sample in a security test frame with an assessor in a UK test laboratory

ArxBridge

LPS 1175 Gates and Grilles Explained

What an LPS 1175 rating covers on gates and grilles: the tested assembly of leaf, posts, fixings and foundations, and what the rating does not prove.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A gate is a moving part of the perimeter, and a grille is a fixed part that still lets air and light through. Both are tested under LPS 1175, and both are tested as assemblies, not as single parts. A gate leaf that held its rating on a test rig carries no rating at all on posts that were never tested, because the attacker goes for the post, the hinge or the lock, not the strongest bar in the leaf. A grille that held its rating in one frame carries no rating in a different frame, because the test never covered that combination.

LPS 1175 Issue 8 lists gates, grilles and blinds, barsets, fences and turnstiles among the products and systems it tests and certifies, beside doors, windows, shutters and walls. The rating works the same way on a gate as it does on a door: a letter for the tool category, from A to H, and a number for the minutes of attack time the product must resist. A gate rated C5 held for five minutes against category C tools, crowbars, drills and chisels. A gate rated B3 held for three minutes against category B tools, screwdrivers, pliers and hand saws. Our LPS 1175 standard page carries the full rating table from A1 to H20, and our anti-ram gates and barriers guide covers the vehicle side of a gate in full.

The sections below work through the gate first, then the grille, then the posts and foundations that hold them, then gates that must stop a vehicle as well as a person, then the operator and the access control, then what the rating does not prove and the mistakes that leave a gate line open. Our security gates cost factors guide covers what drives a gate quote, and our retractable security grilles page covers the grille that folds away when the opening is in use.

  • LPS 1175Gates, grilles, barsets and fences in scope
  • C5 / D10Five and ten minutes against hand and power tools
  • ISO 22343-1Vehicle impact test for anti-ram gates
  • EN 12453Safety in use of power operated gates

A gate is a moving part of the perimeter

A fixed fence is attacked in one place. A gate is attacked in many places, because it moves. The hinges, the lock, the keep, the operator arm and the gap beside the leaf are all parts of the route in, and an LPS 1175 test attacks them all. The test team works against the locked gate as it would be installed, using only the tools permitted for the rating being tested, for the stated number of minutes. A gate that holds its leaf but gives way at the hinges has failed, and a gate that holds its lock but gives way at the keep has failed.

Sliding gates and swing gates fail in different ways. A sliding gate runs on a track, and the track, the rollers and the end stops are tested parts: a gate that can be lifted off its track is a gate that is not held by its lock. A swing gate hangs on hinges, and the hinges, the hinge pins and the frame they fix to are tested parts: a gate that can be lifted off its hinges is a gate that is not held by its lock. The test evidence names the gate type, the leaf, the posts, the hinges or track, the lock and the keep as one assembly, and the order should name the same assembly.

What an LPS 1175 rating covers on a gate

An LPS 1175 rating on a gate covers the complete tested assembly at the stated tool category and time. The rating is written as a letter and a number, and both halves must be read together. A1 is one minute against category A tools, basic hand tools. B3 is three minutes against category B tools. C5 is five minutes against category C tools. D10 is ten minutes against category D tools, sledgehammers, disc cutters and jigsaws. E10, F10 and G10 are ten minutes against heavier tool sets, and H20 is twenty minutes against extreme tools. From D10 upward the attack time stays at ten minutes while the tool sets get heavier, and only H20 extends the time to twenty minutes.

The rating covers the gate in the size and configuration that was tested. A gate tested at one width is not rated at every width, and a gate tested as a single leaf is not rated as a double leaf. The test evidence names the sizes, the leaf type, the infill and the options, and the order should stay inside them. A wider leaf, a taller leaf or a different infill takes the gate outside the tested design unless the evidence covers it. Where a site needs several gates, ask which sizes and configurations the evidence covers before the order is placed, and check that every gate on the schedule sits inside the tested range.

The rating also covers the gate only as installed. A rated gate fitted to untested posts, with the wrong fixings, or with a lock the evidence does not name, has no proven rating. The installation page covers the fitting routine, and installers should follow the post detail, the fixing schedule and the hardware schedule named in the evidence. Our guide to keeping an LPS 1175 rating valid sets out the changes that void a rating after handover, and the inspection routine that keeps it alive.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Grilles and barsets: the opening that still lets air through

A grille protects an opening that must stay open to air, light or sight. A shopfront needs a grille that lets customers see the window after hours. A plant room needs a grille that lets air through to the equipment inside. A basement window needs a grille that lets light in while keeping intruders out. The grille is a set of bars or a mesh fixed across the opening, and its rating depends on the bars, the mesh, the frame and the fixings as one assembly. A bar that can be cut with a hacksaw is not the weak point if the frame can be prised from the wall first, and the test attacks the frame as hard as the bars.

Retractable grilles fold or slide away when the opening is in use, and fixed grilles stay in place. A retractable grille adds moving parts: the tracks, the rollers, the folding joints and the lock that holds it shut. Each of those is a tested part, and the lock must hold the grille across the full width of the opening. A grille that locks at one end and can be lifted at the other has failed. Our retractable security grilles page covers the build behind the grille, and our security shutters vs grilles guide compares the two ways of protecting an opening after hours, including the LPS 1175 ratings each can carry.

Barsets are sets of bars fitted across an opening, and LPS 1175 lists barsets among the products it tests. A barset is only as strong as its fixings: bars set into a frame that is screwed to a wall that cannot hold a fixing can be levered out as one piece. The fixing schedule should name the number, the type and the spacing of the fixings, and the substrate they go into. Where the opening must also resist fire, the grille needs its own fire evidence, because a forced entry rating says nothing about fire, and a fire rating says nothing about forced entry.

Product What the test attacks Rating format What to ask for
Sliding gate Leaf, track, rollers, end stops, lock A1 to H20 Gate type, width, track detail, lock
Swing gate Leaf, hinges, hinge pins, lock, keep A1 to H20 Gate type, width, hinge detail, lock
Retractable grille Bars, tracks, joints, lock A1 to H20 Opening width, track detail, lock position
Fixed grille or barset Bars, mesh, frame, fixings A1 to H20 Bar spacing, frame detail, fixing schedule

Posts, fixings and foundations: the parts below the ground

A gate is only as strong as its posts, and its posts are only as strong as their foundations. A leaf that held its rating on a test rig carries no rating on posts that bend, fixings that pull out, or foundations that move. The post detail is part of the tested assembly: the post section, the depth, the concrete and the ground it was designed for. A gate fitted to shallow posts in soft ground has no proven rating, because the test never covered those posts in that ground.

Foundations decide whether the gate stays where it was put. A sliding gate needs a level track on a foundation that does not settle, because a track that settles lets the gate drop and the lock miss its keep. A swing gate needs posts set deep enough that the weight of the leaf does not pull them out of line, because a post that leans lets the leaf sag and the lock miss its keep. The foundation design should name the depth, the width, the concrete and the ground it was designed for, and the ground should be surveyed before the order is placed, so the design follows what the survey finds.

Fixings decide whether the leaf stays on the gate. Hinge bolts, track bolts and lock keeps must be the ones named in the test evidence, fitted the way the evidence describes. A hinge fitted with the wrong bolts can be undone with a spanner, and a keep fitted with short screws can be prised from the post. The hardware schedule should name every fixing, and the handover pack should name the inspection routine that checks them. Our PAS 68 bollards guide works through the same foundation discipline on a bollard line, and our security gates cost factors guide covers what foundations add to a gate quote.

The gate leaf under daily use: hinges, wheels and the sag that opens a gap

A gate leaf works harder than any other part of a perimeter. It swings, rolls, or slides every time a vehicle passes, and the hinges and the wheels carry the whole weight of the leaf at every move. Check the hinges for wear at the top and the bottom, and look for a leaf that has dropped at the leading edge, because a sagging leaf drags on the ground and leaves a gap at the top that a hand can reach through. A gate that drags will be left open by the next driver, and a gate left open is no gate at all.

Rolling and sliding gates add a track to the list. A track that has filled with grit, gravel, or ice will stop the leaf halfway, and a wheel that has worn flat will let the leaf sit short of its closed position. Clear the track, check the wheels for flat spots, and check that the leaf runs true from one end of the track to the other without a lift at any point. A cantilever gate has no track to clear, but its rollers carry the whole leaf from one end, so check the rollers for wear and the counterbalance for a leaf that has started to dip.

The drop bolt and the latch decide whether the leaf stays shut once it is closed. A drop bolt that will not fall into its socket leaves the leaf free to swing, and a socket that has filled with dirt or frozen will not take the bolt at all. Test the bolt with the leaf shut and again after the leaf has been opened and closed ten times, because a bolt that works once and fails on the tenth close will fail on the night it matters. Our security gates cost factors guide covers what a gate line costs to keep working.

A grille that still lets air through: passage, pitch and the three-digit code

A grille has two jobs that pull in opposite directions: it must let air through and keep a person out. The pitch of the bars decides both, and a pitch that lets a hand through has failed even when it stops a body. LPS 1270 gives a grille three digits for hand, arm and body passage, so read all three before ordering: a grille that stops a hand may still pass an arm. A barset that was tested at one pitch proves nothing about the same bars at a wider pitch, so the test report must name the pitch that will be fitted.

Fixings decide whether the grille stays in the opening. A grille screwed into a frame that was never tested with it is a grille held by screws alone, and screws alone will not hold against a lever. Check that the fixings, the frame and the wall around the opening were tested together, and check that the wall can take the fixings the design names. Our LPS 1175 versus PAS 24 guide covers the forced entry ratings that sit behind a grille.

Part What to check Why it matters
Hinges and wheels Wear, leaf drop, track clear A sagging leaf leaves a gap
Drop bolt and latch Bolt falls, latch throws fully A leaf that will not stay shut
Grille pitch LPS 1270 three digits A hand through is a failure
Vehicle rating ISO 22343-1 report, foundation named Half a rating is no rating

Put the gate, the grille, the fixings and the foundation on one schedule, and keep the test report with the order, so the next specifier can see what the rating rests on. Our ISO 22343 vehicle security barriers guide reads the vehicle rating field by field.

Gates that must stop a vehicle as well as a person

Some gates must do two jobs: keep people out and stop a vehicle. A forced entry rating says nothing about a vehicle, and a vehicle impact rating says nothing about a person with tools. The two jobs need two sets of evidence on one gate: a forced entry rating to LPS 1175 and an impact rating to PAS 68, IWA 14-1 or ISO 22343-1. ISO 22343-1:2023 supersedes PAS 68:2013 and cancels and replaces IWA 14-1:2013, and it is the current vehicle barrier test standard. Our anti-ram gates and barriers guide works through sliding and swing anti-ram gates in full, and our hostile vehicle mitigation page covers the whole line of defence the gate stands in.

An impact rating states the vehicle stopped, the speed, the angle and how far the vehicle travelled past the line. The example rating V/7500[N3]/80/90:0/0 shows the parts: the vehicle type and mass, the impact speed, the impact angle and the penetration distance. Test vehicles run from a 1,500 kg car to a 30,000 kg truck, and test speeds are 48, 64 and 80 km per hour. A 1,500 kg car at 48 km per hour suits urban footways, forecourts and retail frontages, a 2,500 kg 4×4 at 64 km per hour suits city centres and venue approaches, and a 7,500 kg truck at 80 km per hour suits government sites and critical infrastructure. Start from the threat vehicle and the speed it could reach on the approach, and ask for the test report, not the rating string alone.

The rating belongs to the complete tested installation, not to the leaf alone. The posts, the foundations and the ground are part of the tested gate, so a rated leaf on untested posts is not a rated gate. The gap beside the gate is part of the line too: ProtectUK guidance sets 1,200 mm as the maximum clear gap between barriers in a line and 500 mm as the minimum height, so check the whole frontage, not one product. A gate that stops a vehicle and leaves a 2,000 mm gap beside it has left a route through for the next vehicle.

Operators, access control and the power that moves the gate

A powered gate adds an operator, and the operator is part of the assembly. The operator must be sized to the leaf as built, with the infill, the cladding and the wind load the site sees, because an operator sized below the leaf will strain, slow and wear out early. Duty cycle is the share of the day the operator is expected to work, and an operator worked harder than its rating will run hot, slow and wear out early. Count how often the gate will move on the busiest day the site sees, and give that figure to the supplier before the operator is chosen. Our gate automation guide works through operators, duty cycle and safety devices in full.

Safety in use of power operated gates is covered by EN 12453, and the test methods for them are covered by EN 12445. The safety design follows a risk assessment of the entrance: who walks past the leaf, where children and vehicles cross, and what happens when power fails. A gate must not close on a vehicle or a person, and the safety devices need scheduled checks like any other part of the system.

Access control decides who may open the gate and when. A key switch, a code, a card reader or a remote release are the usual methods, and the choice follows who needs to pass and how often. The method should be agreed before the gate is built, not improvised after it, and the routine for changing codes and issuing keys should be written down with the rest of the site procedure. The control system should keep a record of who opened the gate and when. What happens when the power fails must be agreed in advance: a gate that fails open leaves the line open, and a gate that fails shut blocks the vehicles that need to pass, so ask how each failure is handled and how staff release the gate by hand, and test the fail state at handover with the power off.

What a gate or grille rating does not prove

A rating on a gate or a grille proves one thing: the tested assembly held its rating in the test. It proves nothing else. Treat the certificate as a narrow statement, and ask what it leaves out before the order is placed.

It does not prove the line is closed. A gate guards one opening, and a vehicle or a person that cannot pass the gate will look for the gap beside it: an unprotected service entrance, a fence line that was never tested, or a wall that can be climbed. It does not prove the rating suits the threat. The rating names a tool category and a time, and an attacker with heavier tools or more time than the test allowed is outside the rating. It does not prove the gate will keep moving. Duty cycle, servicing and the fail state decide whether the gate works on the busiest day the site sees, and none of those is in the forced entry rating.

It does not prove the gate stops a vehicle. A standard gate is built for access control, not impact, and only a crash tested gate with its tested posts and foundations can stop a determined driver. A rating is a test result for one attack on one assembly, and the rest of the entrance still needs its own evidence.

Mistakes that leave a gate line open

Most gate lines fail in small ways. Each mistake below has the same result: a line that looks complete and lets people or vehicles through unchecked.

The first mistake is ordering the leaf without the posts. The rating covers the installed system, not the leaf alone, so order leaf, posts, fixings and foundations as one system. The second is leaving a gap beside the gate wider than 1,200 mm. A vehicle passes through the gap beside the last barrier, so close every gap to 1,200 mm or below. The third is fitting a lock the evidence does not name. The lock and the keep are tested parts, so fit only the hardware the evidence names. The fourth is leaving the gate in manual mode after a power cut. A gate in manual mode is a gate that is not controlled at all, so put the gate back into automatic use when power returns.

Keep the evidence with the gate. The test report, the foundation drawing, the operator rating and the service routine should travel with the installation, and the handover pack should name the inspection routine the site will follow. For the impact side of the entrance, see our anti-ram gates and barriers guide, and for the factors behind a gate quote, see our security gates cost factors guide. Our 10 steps to specify an LPS 1175 door works through the same evidence discipline for doorsets, and the same habit serves a gate line.

A rated leaf on untested posts is not a rated gate. The rating covers the leaf, the posts, the fixings and the foundations together, or it covers nothing.

Does LPS 1175 cover gates and grilles?

Yes. LPS 1175 Issue 8 lists gates, grilles and blinds, barsets, fences and turnstiles among the products and systems it tests and certifies, beside doors, windows, shutters and walls. The rating works the same way on a gate as on a door: a letter for the tool category and a number for the minutes of attack time.

What is the difference between a forced entry rating and an anti-ram rating on a gate?

A forced entry rating to LPS 1175 states how long the gate held against a person with tools. An anti-ram rating to PAS 68, IWA 14-1 or ISO 22343-1 states which vehicle the gate stopped, at what speed and how far the vehicle travelled past the line. A gate that must do both jobs needs both sets of evidence on the same gate, with its tested posts and foundations.

Can a grille carry the same LPS 1175 rating as a door?

Yes, where the grille was tested to the same rating as a complete assembly. The rating covers the bars or mesh, the frame, the fixings and the lock where the grille moves. A grille rated C5 held for five minutes against category C tools, just as a door rated C5 did, but the two ratings were earned on different products and one does not cover the other.

What should a gate order name for each opening?

The gate type, the width and height, the LPS 1175 rating in full, the impact rating where one is needed, and the leaf, the posts, the fixings, the foundations, the operator and the access control as one system. The test report, the foundation drawing and the service routine should arrive with the gate.

What happens to a powered gate when the power fails?

It depends on the fail state agreed before the gate was built. A gate that fails open leaves the line open, and a gate that fails shut blocks the vehicles that need to pass. The fail state should be written into the specification, the manual release procedure should be agreed with the security team, and the fail state should be tested at handover with the power off.

Specifying a rated gate or grille?Send the opening width, the threat and the rating for a tested gate quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.