ArxBridge
LPS 1175 Gates and Grilles Explained
What an LPS 1175 rating covers on gates and grilles: the tested assembly of leaf, posts, fixings and foundations, and what the rating does not prove.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A gate is a moving part of the perimeter, and a grille is a fixed part that still lets air and light through. Both are tested under LPS 1175, and both are tested as assemblies, not as single parts. A gate leaf that held its rating on a test rig carries no rating at all on posts that were never tested, because the attacker goes for the post, the hinge or the lock, not the strongest bar in the leaf. A grille that held its rating in one frame carries no rating in a different frame, because the test never covered that combination.
LPS 1175 Issue 8 lists gates, grilles and blinds, barsets, fences and turnstiles among the products and systems it tests and certifies, beside doors, windows, shutters and walls. The rating works the same way on a gate as it does on a door: a letter for the tool category, from A to H, and a number for the minutes of attack time the product must resist. A gate rated C5 held for five minutes against category C tools, crowbars, drills and chisels. A gate rated B3 held for three minutes against category B tools, screwdrivers, pliers and hand saws. Our LPS 1175 standard page carries the full rating table from A1 to H20, and our anti-ram gates and barriers guide covers the vehicle side of a gate in full.
The sections below work through the gate first, then the grille, then the posts and foundations that hold them, then gates that must stop a vehicle as well as a person, then the operator and the access control, then what the rating does not prove and the mistakes that leave a gate line open. Our security gates cost factors guide covers what drives a gate quote, and our retractable security grilles page covers the grille that folds away when the opening is in use.
- LPS 1175Gates, grilles, barsets and fences in scope
- C5 / D10Five and ten minutes against hand and power tools
- ISO 22343-1Vehicle impact test for anti-ram gates
- EN 12453Safety in use of power operated gates
A gate is a moving part of the perimeter
A fixed fence is attacked in one place. A gate is attacked in many places, because it moves. The hinges, the lock, the keep, the operator arm and the gap beside the leaf are all parts of the route in, and an LPS 1175 test attacks them all. The test team works against the locked gate as it would be installed, using only the tools permitted for the rating being tested, for the stated number of minutes. A gate that holds its leaf but gives way at the hinges has failed, and a gate that holds its lock but gives way at the keep has failed.
Sliding gates and swing gates fail in different ways. A sliding gate runs on a track, and the track, the rollers and the end stops are tested parts: a gate that can be lifted off its track is a gate that is not held by its lock. A swing gate hangs on hinges, and the hinges, the hinge pins and the frame they fix to are tested parts: a gate that can be lifted off its hinges is a gate that is not held by its lock. The test evidence names the gate type, the leaf, the posts, the hinges or track, the lock and the keep as one assembly, and the order should name the same assembly.
What an LPS 1175 rating covers on a gate
An LPS 1175 rating on a gate covers the complete tested assembly at the stated tool category and time. The rating is written as a letter and a number, and both halves must be read together. A1 is one minute against category A tools, basic hand tools. B3 is three minutes against category B tools. C5 is five minutes against category C tools. D10 is ten minutes against category D tools, sledgehammers, disc cutters and jigsaws. E10, F10 and G10 are ten minutes against heavier tool sets, and H20 is twenty minutes against extreme tools. From D10 upward the attack time stays at ten minutes while the tool sets get heavier, and only H20 extends the time to twenty minutes.
The rating covers the gate in the size and configuration that was tested. A gate tested at one width is not rated at every width, and a gate tested as a single leaf is not rated as a double leaf. The test evidence names the sizes, the leaf type, the infill and the options, and the order should stay inside them. A wider leaf, a taller leaf or a different infill takes the gate outside the tested design unless the evidence covers it. Where a site needs several gates, ask which sizes and configurations the evidence covers before the order is placed, and check that every gate on the schedule sits inside the tested range.
The rating also covers the gate only as installed. A rated gate fitted to untested posts, with the wrong fixings, or with a lock the evidence does not name, has no proven rating. The installation page covers the fitting routine, and installers should follow the post detail, the fixing schedule and the hardware schedule named in the evidence. Our guide to keeping an LPS 1175 rating valid sets out the changes that void a rating after handover, and the inspection routine that keeps it alive.
Grilles and barsets: the opening that still lets air through
A grille protects an opening that must stay open to air, light or sight. A shopfront needs a grille that lets customers see the window after hours. A plant room needs a grille that lets air through to the equipment inside. A basement window needs a grille that lets light in while keeping intruders out. The grille is a set of bars or a mesh fixed across the opening, and its rating depends on the bars, the mesh, the frame and the fixings as one assembly. A bar that can be cut with a hacksaw is not the weak point if the frame can be prised from the wall first, and the test attacks the frame as hard as the bars.
Retractable grilles fold or slide away when the opening is in use, and fixed grilles stay in place. A retractable grille adds moving parts: the tracks, the rollers, the folding joints and the lock that holds it shut. Each of those is a tested part, and the lock must hold the grille across the full width of the opening. A grille that locks at one end and can be lifted at the other has failed. Our retractable security grilles page covers the build behind the grille, and our security shutters vs grilles guide compares the two ways of protecting an opening after hours, including the LPS 1175 ratings each can carry.
Barsets are sets of bars fitted across an opening, and LPS 1175 lists barsets among the products it tests. A barset is only as strong as its fixings: bars set into a frame that is screwed to a wall that cannot hold a fixing can be levered out as one piece. The fixing schedule should name the number, the type and the spacing of the fixings, and the substrate they go into. Where the opening must also resist fire, the grille needs its own fire evidence, because a forced entry rating says nothing about fire, and a fire rating says nothing about forced entry.
| Product | What the test attacks | Rating format | What to ask for |
|---|---|---|---|
| Sliding gate | Leaf, track, rollers, end stops, lock | A1 to H20 | Gate type, width, track detail, lock |
| Swing gate | Leaf, hinges, hinge pins, lock, keep | A1 to H20 | Gate type, width, hinge detail, lock |
| Retractable grille | Bars, tracks, joints, lock | A1 to H20 | Opening width, track detail, lock position |
| Fixed grille or barset | Bars, mesh, frame, fixings | A1 to H20 | Bar spacing, frame detail, fixing schedule |
Posts, fixings and foundations: the parts below the ground
A gate is only as strong as its posts, and its posts are only as strong as their foundations. A leaf that held its rating on a test rig carries no rating on posts that bend, fixings that pull out, or foundations that move. The post detail is part of the tested assembly: the post section, the depth, the concrete and the ground it was designed for. A gate fitted to shallow posts in soft ground has no proven rating, because the test never covered those posts in that ground.
Foundations decide whether the gate stays where it was put. A sliding gate needs a level track on a foundation that does not settle, because a track that settles lets the gate drop and the lock miss its keep. A swing gate needs posts set deep enough that the weight of the leaf does not pull them out of line, because a post that leans lets the leaf sag and the lock miss its keep. The foundation design should name the depth, the width, the concrete and the ground it was designed for, and the ground should be surveyed before the order is placed, so the design follows what the survey finds.
Fixings decide whether the leaf stays on the gate. Hinge bolts, track bolts and lock keeps must be the ones named in the test evidence, fitted the way the evidence describes. A hinge fitted with the wrong bolts can be undone with a spanner, and a keep fitted with short screws can be prised from the post. The hardware schedule should name every fixing, and the handover pack should name the inspection routine that checks them. Our PAS 68 bollards guide works through the same foundation discipline on a bollard line, and our security gates cost factors guide covers what foundations add to a gate quote.
The gate leaf under daily use: hinges, wheels and the sag that opens a gap
A gate leaf works harder than any other part of a perimeter. It swings, rolls, or slides every time a vehicle passes, and the hinges and the wheels carry the whole weight of the leaf at every move. Check the hinges for wear at the top and the bottom, and look for a leaf that has dropped at the leading edge, because a sagging leaf drags on the ground and leaves a gap at the top that a hand can reach through. A gate that drags will be left open by the next driver, and a gate left open is no gate at all.
Rolling and sliding gates add a track to the list. A track that has filled with grit, gravel, or ice will stop the leaf halfway, and a wheel that has worn flat will let the leaf sit short of its closed position. Clear the track, check the wheels for flat spots, and check that the leaf runs true from one end of the track to the other without a lift at any point. A cantilever gate has no track to clear, but its rollers carry the whole leaf from one end, so check the rollers for wear and the counterbalance for a leaf that has started to dip.
The drop bolt and the latch decide whether the leaf stays shut once it is closed. A drop bolt that will not fall into its socket leaves the leaf free to swing, and a socket that has filled with dirt or frozen will not take the bolt at all. Test the bolt with the leaf shut and again after the leaf has been opened and closed ten times, because a bolt that works once and fails on the tenth close will fail on the night it matters. Our security gates cost factors guide covers what a gate line costs to keep working.
A grille that still lets air through: passage, pitch and the three-digit code
A grille has two jobs that pull in opposite directions: it must let air through and keep a person out. The pitch of the bars decides both, and a pitch that lets a hand through has failed even when it stops a body. LPS 1270 gives a grille three digits for hand, arm and body passage, so read all three before ordering: a grille that stops a hand may still pass an arm. A barset that was tested at one pitch proves nothing about the same bars at a wider pitch, so the test report must name the pitch that will be fitted.
Fixings decide whether the grille stays in the opening. A grille screwed into a frame that was never tested with it is a grille held by screws alone, and screws alone will not hold against a lever. Check that the fixings, the frame and the wall around the opening were tested together, and check that the wall can take the fixings the design names. Our LPS 1175 versus PAS 24 guide covers the forced entry ratings that sit behind a grille.
| Part | What to check | Why it matters |
|---|---|---|
| Hinges and wheels | Wear, leaf drop, track clear | A sagging leaf leaves a gap |
| Drop bolt and latch | Bolt falls, latch throws fully | A leaf that will not stay shut |
| Grille pitch | LPS 1270 three digits | A hand through is a failure |
| Vehicle rating | ISO 22343-1 report, foundation named | Half a rating is no rating |
Put the gate, the grille, the fixings and the foundation on one schedule, and keep the test report with the order, so the next specifier can see what the rating rests on. Our ISO 22343 vehicle security barriers guide reads the vehicle rating field by field.
Gates that must stop a vehicle as well as a person
Some gates must do two jobs: keep people out and stop a vehicle. A forced entry rating says nothing about a vehicle, and a vehicle impact rating says nothing about a person with tools. The two jobs need two sets of evidence on one gate: a forced entry rating to LPS 1175 and an impact rating to PAS 68, IWA 14-1 or ISO 22343-1. ISO 22343-1:2023 supersedes PAS 68:2013 and cancels and replaces IWA 14-1:2013, and it is the current vehicle barrier test standard. Our anti-ram gates and barriers guide works through sliding and swing anti-ram gates in full, and our hostile vehicle mitigation page covers the whole line of defence the gate stands in.
An impact rating states the vehicle stopped, the speed, the angle and how far the vehicle travelled past the line. The example rating V/7500[N3]/80/90:0/0 shows the parts: the vehicle type and mass, the impact speed, the impact angle and the penetration distance. Test vehicles run from a 1,500 kg car to a 30,000 kg truck, and test speeds are 48, 64 and 80 km per hour. A 1,500 kg car at 48 km per hour suits urban footways, forecourts and retail frontages, a 2,500 kg 4×4 at 64 km per hour suits city centres and venue approaches, and a 7,500 kg truck at 80 km per hour suits government sites and critical infrastructure. Start from the threat vehicle and the speed it could reach on the approach, and ask for the test report, not the rating string alone.
The rating belongs to the complete tested installation, not to the leaf alone. The posts, the foundations and the ground are part of the tested gate, so a rated leaf on untested posts is not a rated gate. The gap beside the gate is part of the line too: ProtectUK guidance sets 1,200 mm as the maximum clear gap between barriers in a line and 500 mm as the minimum height, so check the whole frontage, not one product. A gate that stops a vehicle and leaves a 2,000 mm gap beside it has left a route through for the next vehicle.
Operators, access control and the power that moves the gate
A powered gate adds an operator, and the operator is part of the assembly. The operator must be sized to the leaf as built, with the infill, the cladding and the wind load the site sees, because an operator sized below the leaf will strain, slow and wear out early. Duty cycle is the share of the day the operator is expected to work, and an operator worked harder than its rating will run hot, slow and wear out early. Count how often the gate will move on the busiest day the site sees, and give that figure to the supplier before the operator is chosen. Our gate automation guide works through operators, duty cycle and safety devices in full.
Safety in use of power operated gates is covered by EN 12453, and the test methods for them are covered by EN 12445. The safety design follows a risk assessment of the entrance: who walks past the leaf, where children and vehicles cross, and what happens when power fails. A gate must not close on a vehicle or a person, and the safety devices need scheduled checks like any other part of the system.
Access control decides who may open the gate and when. A key switch, a code, a card reader or a remote release are the usual methods, and the choice follows who needs to pass and how often. The method should be agreed before the gate is built, not improvised after it, and the routine for changing codes and issuing keys should be written down with the rest of the site procedure. The control system should keep a record of who opened the gate and when. What happens when the power fails must be agreed in advance: a gate that fails open leaves the line open, and a gate that fails shut blocks the vehicles that need to pass, so ask how each failure is handled and how staff release the gate by hand, and test the fail state at handover with the power off.
What a gate or grille rating does not prove
A rating on a gate or a grille proves one thing: the tested assembly held its rating in the test. It proves nothing else. Treat the certificate as a narrow statement, and ask what it leaves out before the order is placed.
It does not prove the line is closed. A gate guards one opening, and a vehicle or a person that cannot pass the gate will look for the gap beside it: an unprotected service entrance, a fence line that was never tested, or a wall that can be climbed. It does not prove the rating suits the threat. The rating names a tool category and a time, and an attacker with heavier tools or more time than the test allowed is outside the rating. It does not prove the gate will keep moving. Duty cycle, servicing and the fail state decide whether the gate works on the busiest day the site sees, and none of those is in the forced entry rating.
It does not prove the gate stops a vehicle. A standard gate is built for access control, not impact, and only a crash tested gate with its tested posts and foundations can stop a determined driver. A rating is a test result for one attack on one assembly, and the rest of the entrance still needs its own evidence.
Mistakes that leave a gate line open
Most gate lines fail in small ways. Each mistake below has the same result: a line that looks complete and lets people or vehicles through unchecked.
The first mistake is ordering the leaf without the posts. The rating covers the installed system, not the leaf alone, so order leaf, posts, fixings and foundations as one system. The second is leaving a gap beside the gate wider than 1,200 mm. A vehicle passes through the gap beside the last barrier, so close every gap to 1,200 mm or below. The third is fitting a lock the evidence does not name. The lock and the keep are tested parts, so fit only the hardware the evidence names. The fourth is leaving the gate in manual mode after a power cut. A gate in manual mode is a gate that is not controlled at all, so put the gate back into automatic use when power returns.
Keep the evidence with the gate. The test report, the foundation drawing, the operator rating and the service routine should travel with the installation, and the handover pack should name the inspection routine the site will follow. For the impact side of the entrance, see our anti-ram gates and barriers guide, and for the factors behind a gate quote, see our security gates cost factors guide. Our 10 steps to specify an LPS 1175 door works through the same evidence discipline for doorsets, and the same habit serves a gate line.
A rated leaf on untested posts is not a rated gate. The rating covers the leaf, the posts, the fixings and the foundations together, or it covers nothing.
Does LPS 1175 cover gates and grilles?
Yes. LPS 1175 Issue 8 lists gates, grilles and blinds, barsets, fences and turnstiles among the products and systems it tests and certifies, beside doors, windows, shutters and walls. The rating works the same way on a gate as on a door: a letter for the tool category and a number for the minutes of attack time.
What is the difference between a forced entry rating and an anti-ram rating on a gate?
A forced entry rating to LPS 1175 states how long the gate held against a person with tools. An anti-ram rating to PAS 68, IWA 14-1 or ISO 22343-1 states which vehicle the gate stopped, at what speed and how far the vehicle travelled past the line. A gate that must do both jobs needs both sets of evidence on the same gate, with its tested posts and foundations.
Can a grille carry the same LPS 1175 rating as a door?
Yes, where the grille was tested to the same rating as a complete assembly. The rating covers the bars or mesh, the frame, the fixings and the lock where the grille moves. A grille rated C5 held for five minutes against category C tools, just as a door rated C5 did, but the two ratings were earned on different products and one does not cover the other.
What should a gate order name for each opening?
The gate type, the width and height, the LPS 1175 rating in full, the impact rating where one is needed, and the leaf, the posts, the fixings, the foundations, the operator and the access control as one system. The test report, the foundation drawing and the service routine should arrive with the gate.
What happens to a powered gate when the power fails?
It depends on the fail state agreed before the gate was built. A gate that fails open leaves the line open, and a gate that fails shut blocks the vehicles that need to pass. The fail state should be written into the specification, the manual release procedure should be agreed with the security team, and the fail state should be tested at handover with the power off.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.