GP Surgery Security Doors Explained

A GP surgery guards consulting rooms, records and drugs stores, so each leaf takes the grade the room behind it demands, from reception to plant room.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A GP surgery is a reception, a set of consulting rooms and a drugs store behind one entrance, and the doors between those parts decide what stays where it belongs. The consulting rooms hold the patients, the records room holds the files, and the drugs store holds the controlled drugs, so each door takes its proof from the room behind it.

LPS 1175 sets the grade on a surgery door, and the category follows what sits behind the leaf. Issue 8.2 of September 2024 names the three categories B3, C5 and D10, at three, five and ten minutes. The entrance takes the lowest of the three, the consulting rooms and the back offices take the middle one, and the drugs store takes the highest.

A GP surgery follows the same rules as any other clinical building. The hospital security doors guide covers the doors of a hospital, not a surgery, and the security doors for dental practices guide covers the doors of a dental practice, which holds surgeries of a different kind. The surgery order names every door, with the grade and the lock beside each one, so the door that arrives is the one its room asked for.

  • LPS 1175 B3 / C5 / D10Forced entry grades to Issue 8.2
  • Consulting roomsWhere the grade rises
  • D10The drugs store grade
  • One listEvery surgery door named

Reception, consulting rooms and stores: one surgery, three grades

Three parts make up a GP surgery, and the grade follows what each part holds. The reception meets the patients, the consulting rooms hold the patients and the records, and the stores hold the drugs and the equipment, so each part takes the doors its work demands.

The entrance leaf opens for every patient who arrives and shuts behind them on its own, because a leaf left standing open guards nothing. The consulting room leaf stands shut through the clinic, and it must hold against the attack the records behind it invite.

The order is written from a list that names every opening, the leaf it takes and the grade beside it, because a leaf with no line on the list may turn up in the wrong consulting room.

The consulting room door: the leaf that guards the patient and the record

Behind every consulting room door sits a patient and a record, and the leaf that guards them takes the grade the value behind it demands. C5 suits the consulting room, because the records behind it justify the minutes it takes to break through, and the leaf must hold until the alarm is answered.

Only the surgery team holds the key to the consulting rooms, because patients must never pass them alone. The consulting room leaf takes C5, the records room beside it takes C5, and the entrance takes B3.

A consulting room leaf must keep voices in as well as intruders out, so the seals round the leaf and the closer that brings it home after every person through do double work. A leaf that will not shut on its own leaves the patient inside heard in the corridor, so the closer is tried on the round.

Where a consulting room leaf must hold fire as well as forced entry, the two proofs are taken on the same doorset and sit in one report. EN 1634-1 proves the minutes and the letters, LPS 1175 proves the grade, and the fire and security doors dual certification guide shows how the pair is proved on one leaf, frame and seals.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

The drugs store takes D10 and the records room takes C5

The drugs store holds the controlled drugs, and the leaf that guards it takes the highest grade the standard names. D10 suits the drugs store, because ten minutes against the tools the test names is the hold the drugs behind it demand, and the leaf, the frame, the fixings and the lock are proved together as one doorset, with the report naming the grade it holds.

The records room holds the patient files, and its leaf takes C5, because the files behind it justify the minutes it takes to break through. The drugs store and the records room sit behind the same corridor, so their leaves take different grades, and the order names the grade beside each door so the fitter does not swap them. The security doors for pharmacies guide takes the same care with the drugs store of a pharmacy.

Drawings drawn before Issue 8 call the same three categories SR2, SR3 and SR4, so the order carries both names beside each door for the fitter who reads them. The keeping an LPS 1175 rating valid guide sets out what can break a rating once a door is fitted.

The reception desk: the first leaf a patient reaches

The entrance leaf must open for every patient who arrives and hold an intruder out once the surgery shuts, so the leaf, the frame and the lock are proved as one doorset, and the test report names all three.

The closer on the entrance leaf is set so the leaf comes home without a slam after every patient through it, and the pull is checked by opening the leaf and watching it shut on its own. A leaf that stands open at the end of the clinic guards nothing, so the closer is tried before the surgery opens each morning.

The entrance leaf can carry a glazed panel so reception sees who waits outside, and the pane is proved with the leaf round it rather than alone. The bead and the fixings that hold the pane are named in the test report, and what the pane adds to the figure is set out in the fire rated glass cost guide.

Keys, cards and the hatch: how surgery staff move through the building

Every leaf behind reception opens for the surgery team and stays shut for the public, and a reader beside each leaf opens only for the cards the list names. The fire door hardware guide sets out what that lock must do, while the security door locks guide names what the lock on a surgery leaf must hold.

The readers, the releases and the wiring beside each leaf are covered in the door entry systems guide, which names what each part beside a leaf must do. The hatch at the dispensary lets prescriptions pass without opening the drugs store leaf, and the hatch takes the same grade as the leaf beside it.

The order names, leaf by leaf, what happens when the power fails, so the team knows which leaves open and which stay shut on the night the supply goes. A leaf with no answer beside it leaves the team guessing when the answer matters most.

Glazed leaves in a consulting room: light in, eyes out

A consulting room needs light from the corridor and privacy from it at the same time, so the glazed leaf takes glass that lets light through without letting eyes through. The glass takes the same proof as the leaf round it, and the bead and the fixings that hold it are named in the test report.

The waiting room sits behind a leaf that must open for every patient who arrives and shut behind them on its own. The fire door regulations hospitals guide takes the same care with the waiting areas of a hospital, and the fire door regulations dental practices guide takes it with the waiting room of a dental practice.

A leaf that must stay open through the clinic needs a hold-open device proved to BS EN 1155, which shuts the leaf on its own the moment the alarm sounds. The leaf is hung with a 4 mm gap round it, and the gauge on the round checks that the gap has not widened, because a wider gap points at a hinge or a frame that has moved.

Position Door Grade What to check
Entrance Glazed leaf LPS 1175 B3 Leaf, glass, closer
Consulting rooms Steel leaf LPS 1175 C5 Leaf, lock, seals
Records room Steel leaf LPS 1175 C5 Leaf, lock, seals
Drugs store Steel leaf LPS 1175 D10 Leaf, lock, seals
Back office Steel leaf LPS 1175 C5 Leaf, lock, reader
Plant room Steel leaf LPS 1175 C5 Leaf, lock, seals

One leaf, two proofs: fire and forced entry in a surgery

Where a surgery leaf must hold fire as well as forced entry, both proofs are taken on the same doorset. EN 1634-1 proves the period in minutes and letters from 30 to 120, LPS 1175 proves the grade in B3, C5 and D10, and the leaf, the frame and the seals are tested together for both, so one report holds the two proofs.

Smoke reaches the people on the escape route before the flame does, so the route leaves carry a smoke rating beside their period. BS EN 1634-3 names the two ratings, Sa for smoke at room temperature and S200 for smoke at 200 degrees, and the seal that earns the rating must meet the frame all round without a break. How the doors keep smoke back is worked through in the smoke control doors guide.

The alarm sends patients who have never used the building towards the way out, so the route is signed at every turn and kept clear of chairs, tables and stores. A leaf on the route must open to one push from whoever reaches it first, whether the power is on or off.

The surgery order: every leaf, its grade and its lock

One list carries the whole surgery order, with a line for every opening that names the leaf, the grade, the lock and the closer beside it. A list that names one leaf for the whole surgery leaves the fitter to guess which room takes which grade, and a leaf fitted in the wrong room guards the wrong thing.

The figures are settled leaf by leaf before the order is signed, because a leaf with no figure beside it still arrives on the invoice, and hardware ordered after the doorset costs more than hardware ordered with it. The how to specify security doors guide lists what the schedule must hold for every door, and the security door cost factors guide names what moves the figure when the grade steps up.

The practice manager walks the surgery with the door list once a month, trying a few leaves on each walk so every leaf is tried before the month is out. The entrance is tried at opening, the consulting rooms before the first patient, and the drugs store at closing. The record of each walk stays with the surgery file, and the fire door inspection checklist names what the walk should cover.

A surgery door holds only as long as the rooms behind it and the reception beside it, so the grade, the period and the lock must all sit on the same list.

What grade should a GP surgery door carry?

B3, C5 or D10 to LPS 1175. The consulting rooms take the middle category on the site, the records room takes the middle one, the drugs store takes the highest, and the entrance takes the lowest, so the grade follows the room behind the leaf.

Can one leaf hold fire and forced entry?

Yes, where both proofs were taken on one doorset, so the report names the period and the grade together.

Do GP surgery doors need access control?

Yes, the doors behind reception take a reader beside the leaf, so staff can open them and patients cannot pass after hours.

What period should a surgery door carry?

The surgery order lists the period leaf by leaf, and each one is proved to EN 1634-1. A consulting room leaf holds fire longer than a leaf on the public route.

Who checks the GP surgery doors?

The practice manager tries the doors a few at a time through the month, and each fault is written against its own door on the day it is found. The record of the round stays with the surgery file.

Specifying doors for a GP surgery?Send the door list and the grade each room must hold for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.