ArxBridge
Thermally broken steel security doors: U-values and certification
How thermally broken steel security doors cut heat loss: thermal breaks, U-values, Part L, and combining thermal and security ratings in one tested doorset.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A thermally broken steel security door places a low-conductivity barrier inside the frame and leaf so heat cannot pass straight through the metal. The U-value falls while the forced-entry rating stays. Specify the thermal and security ratings together, and check any Passivhaus-level claim against the door’s own test certificate.
- Thermal breakAn insulating barrier that splits the steel frame into inner and outer zones
- U-valueHeat loss per square metre per degree, quoted per doorset in W/m²K
- Security keptLPS 1175 ratings apply to the complete doorset, break included
- ProofBoth ratings must appear on the same test certificate
What a thermal break is and where it sits in the door
A thermal break is a strip of low-conductivity material, usually a reinforced polymer, set into the frame profile and the door leaf. It divides the steelwork into an inner section and an outer section that never touch. Heat travelling through the metal meets the barrier and slows. The break runs the full perimeter of the frame and continues through thresholds, transoms and mullions, so there is no uninterrupted metal path from outside to inside. Our thermally broken doors page explains the product range this guide supports.
In the leaf, the break sits between the outer and inner skins and works with the insulating core. The hardware needs the same thinking: fixings, lock cases and hinges can bridge the break if they are specified carelessly, so the ironmongery schedule should keep the thermal split intact. A door that is broken in the frame but bridged at the lock keeps only half of its benefit.
Why steel doors need thermal breaks more than other materials
Steel conducts heat far more readily than timber or PVC-U. In winter the outer face cools, the inner face follows, and the room loses heat through the doorset around the clock. The same conduction works in reverse in summer, bringing warmth in. Timber and PVC-U are poor conductors, so they insulate by nature. Steel must be engineered to insulate, and the break is the engineering.
The security side makes the problem sharper. A rated steel door is heavy, with thick skins and a dense core, and it often guards a heated space such as a plant room lobby or a residential entrance. Without a break, the most secure door in the building can also be its worst thermal performer.
U-values: what the number actually means
The U-value states how much heat passes through one square metre of the doorset for each degree of temperature difference, in watts per square metre kelvin (W/m²K). A lower number means less heat loss. The figure applies to the complete doorset, frame, leaf, glazing and seals together, not to the steel alone. Two doors with the same leaf can quote different U-values if their frames or seals differ.
Ask for the U-value of the exact doorset size and configuration you are buying. A value quoted for a small solid door will not match a large glazed one. The number should come from calculation or test for that build, and it should sit next to the security and fire ratings on the same documentation.
Part L and replacement doors in general terms
Part L of the Building Regulations sets energy efficiency requirements for buildings in England and Wales, with equivalent rules in Scotland and Northern Ireland. Replacement doors in existing buildings must meet U-value limits, and new buildings must meet an overall energy target that the doorset helps to satisfy.
In practice this means a security door on an external wall cannot be specified on rating alone. The schedule should name the U-value limit that applies to the project and require the doorset to meet it. A thermally broken construction is the usual route for steel. Keep the requirement in general terms on early schedules and pin it to a number once the energy assessor confirms the target.
Do thermal breaks weaken the security rating?
A thermal break does not lower the LPS 1175 rating, because the rating is earned by the complete doorset as tested. The test attacks the door, frame, locks and glazing with the tool set for the claimed category, and the break is part of what is attacked. A B3 (SR2) door with a thermal break has resisted screwdrivers, pliers and hand saws for three minutes with the break in place.
What matters is that the rating and the break belong to the same tested construction. A security rating borrowed from a solid-leaf test does not transfer to a thermally broken variant. Ask for one certificate that names the thermal break construction and the LPS 1175 rating together.
Condensation, cold bridging and the frame
Where warm indoor air meets a cold steel surface, moisture condenses. On a non-broken frame this shows as damp patches, streaks and eventually corrosion at the frame edges. The thermal break lifts the internal surface temperature, which moves the frame away from the dew point in normal conditions. Corridors and lobbies stay drier and the decoration lasts longer.
The break cannot fix bad detailing around it. Gaps in seals, uninsulated fixing points and cold thresholds will still condense. Treat the doorset, the seals and the surrounding wall junction as one detail, and make sure the installer understands that packing the frame with conductive fixings undoes the break.
Passivhaus-level claims: verify them on the certificate
Some doors are described as suitable for Passivhaus or low-energy projects. That description is only as good as the paperwork behind it. Passivhaus performance depends on the whole building calculation, and a door contributes its U-value, airtightness and installation detail. A general claim without numbers helps no one.
Before accepting the claim, ask for the door’s own test certificate and check three things: the U-value quoted for your doorset size, the airtightness result, and whether the certificate covers the exact construction including glazing and ironmongery. If any of those are missing, treat the claim as marketing and specify from the numbers you can verify.
Specifying thermal and security ratings together
Put both performances in one specification clause. Name the LPS 1175 rating, the fire rating if needed, and the U-value, then require a single test certificate or certificate set that covers that exact doorset. Separate documents for a security door and a thermal door describe two different products. Fire rated steel doors with thermal breaks follow the same rule: one tested assembly, one evidence set.
Send the drawings and the opening schedule through the quote form so the doorset can be priced as one tested assembly. Note any glazed areas, louvres or access control, since each changes the thermal calculation. Plant rooms in our data centre physical security guide show why the schedule must capture every opening. The factory then builds the door that was tested, not an approximation of it. Browse the rest of our guides for related specification topics.
| Factor | Effect on the U-value | What to check |
|---|---|---|
| Frame construction | A thermal break lowers it; solid steel raises it | The break runs the full frame perimeter |
| Glazing | Large glazed areas raise it unless high-performance units are used | The glazing spec matches the certificate |
| Leaf core | An insulating core lowers it | The core is named in the test evidence |
| Seals and thresholds | Poor sealing raises air leakage and effective loss | Seals are part of the tested assembly |
| Doorset size | Size changes the frame-to-leaf ratio | The U-value is quoted for your size |
One certificate, both ratings. A security rating and a U-value from different documents describe different doors. Ask for both on the same test evidence.
Can one doorset be LPS 1175 rated and thermally broken?
Yes. The rating is tested on the complete doorset with the break in place. Ask for the certificate that names both the thermal break construction and the LPS 1175 rating.
What U-value should I specify?
The one your energy assessor needs for compliance, quoted for your exact doorset size and configuration. There is no single correct figure for every project.
Does the thermal break change the fire rating?
Fire performance is tested separately to EN 1634-1. A combined door needs its own fire test evidence for the E, EW or EI period claimed.
Will a thermal break stop condensation entirely?
It raises internal surface temperatures and greatly reduces the risk, but seals, thresholds and installation detailing must be right too.
How do I check a Passivhaus-level claim?
Ask for the door’s own certificate: the U-value for your size, the airtightness result, and the exact construction covered. Accept only what the paperwork proves.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.