A prison holds people in and lets people out, so each fire door takes its period from the part of the building behind it, from the cell to the public counter.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A prison holds people in and lets people out, and the fire doors must do both at once. The leaf must hold fire back for its period, and it must open for the staff who run the building and the visitors who came to see it, while the cell doors hold the people inside.
Each door in a prison takes its period from the part of the building behind it, because the cell, the wing and the public counter ask different things of the leaf. The order names the period beside each opening, so the door that arrives is the door the part needs.
The doors themselves are covered in the prison security doors guide, and the rules for the shared parts of a public building are set out in the fire door regulations commercial buildings guide. The prison order names every door in the building, with the period and the hardware beside each one.
- FD30 / FD60Fire periods to EN 1634-1
- E / EW / EI 30-120What the letters beside the period mean
- 4 mmThe gap round the leaf
- One listEvery prison door named
Custody, wings and public counters: one building, three regimes
A prison divides into three parts, and the rules follow the parts. The custody suites hold the people who have just arrived, the wings hold the people who live there, and the public counters serve the visitors who came to see them. A door between one part and the next must hold the line between them, so a fire stays where it started and the people behind the leaf reach the way out.
The custody suite takes the doors that hold people in, and each leaf must hold fire back while the staff decide who moves where. The wing takes the doors that divide the building, and each leaf takes the period the way out needs. The public counter takes the doors that face the visitors, and each leaf must open for people who have never walked the route before.
The schedule is written before the order goes out, with every opening on it and the period beside each one. A door that arrives without a line on the schedule is a door nobody can place, so the list is finished before the order is placed.
The periods each part of a prison takes: FD30 and FD60
Each part of a prison asks a different period of its doors, because the load behind each leaf is different. The cell holds one person behind a locked leaf, the wing holds many people behind leaves that must open together, and the plant room holds the machinery that serves the building, so the period on each door follows the part, not the leaf.
The proof of a doorset under EN 1634-1 is written as minutes with letters beside them. The minutes run from 30 to 120, and the letters name what the doorset held back: flames alone, flames with some of the heat, or flames with the heat as well. The minutes and the letters sit together on the order, because the minutes on their own name only half the proof.
A longer period takes a heavier leaf, a deeper frame and seals that hold longer, so the price rises with the period. A leaf proved for 30 minutes has no place on an opening that must hold 60. The fire door regulations commercial buildings guide names the periods for the shared parts of a public building.
Cell doors: the leaf that holds fire and holds the person in
The cell door takes two jobs that pull against each other. It must hold fire back for its period, and it must hold the person in the cell behind it, so the leaf, the frame and the lock are proved together as one doorset, and the report names each one.
The cell leaf takes a lock that the staff control from outside, because the person inside must not open it, and the leaf must still open from the staff side when the alarm sounds. A leaf that cannot be opened by the staff who run the wing is a leaf that traps the person behind it. The lock the key turns is covered in the security door locks guide.
The cell door takes an observation pane, so the staff can see into the cell without opening the leaf, and the pane takes the same proof as the leaf itself, because a door that holds while the glass beside it fails has held nothing. The bead and the fixings round the pane are the ones the test report names.
The wing doors: the leaves that divide the building
The wing doors divide the building into compartments, and each leaf takes the period the wall beside it takes. A fire that starts on one wing must stay on that wing, so the leaf between the wings holds the line while the staff move the people on the other side.
The wing leaf takes a closer that pulls it shut after every person who passes, because a leaf left open is a compartment wall with a hole in it. A fire door closer takes no less than EN 3 to BS EN 1154, and the test is simple: open the leaf and watch it shut on its own.
The wing doors take the hardware the staff can work in the dark, because the alarm may sound at night and the lights may be out. The closers that pull the leaf shut are covered in the fire door closers guide, and the lock the key turns is covered in the fire door hardware guide.
The way out for staff and visitors: the public route
Visitors follow the route the building gives them, and the way out must be clear when the alarm sounds. Any door on that route opens with one push from whoever reaches it, because the leaf must open whatever the power is doing.
The route doors carry smoke seals to BS EN 1634-3, Sa for smoke at room temperature and S200 for smoke at 200 degrees. A seal must meet the frame all round, because smoke reaches the route before the flames do, and the gap the leaf leaves is closed by the seal. The doors that hold smoke back while people move past them are covered in the smoke control doors guide.
No door on a route takes a shorter period than the route needs, because the leaf with the shortest period fails first. The doors on a public building that fills with visitors are covered in the fire door regulations leisure centres guide.
Fail safe and fail secure: which prison door takes which
A prison door must answer one question before it is ordered: what does the leaf do when the power fails. A leaf on an escape route opens when the power fails, because the way out must work in a blackout, and a leaf that guards a cell stays shut, because the person behind it must stay there.
Fail safe means the leaf releases when the power goes, and fail secure means the leaf stays locked when the power goes, and the answer is written beside each door on the schedule before the order goes out. A leaf ordered without that answer may do the wrong thing on the night it matters.
The release on each leaf throws the latch with one push, and the leaf swings open even when the power has gone, where the route needs it to. The entry system beside the leaf is covered in the door entry systems guide, and the readers, fobs and codes that open the doors are set out in the same place.
Anti-ligature and observation: the cell door in detail
The cell door takes no handle, hook or edge a person could use to harm themselves, because the leaf is the closest thing to the person behind it. Every fitting on the cell leaf is chosen so there is nothing to tie to, and the lock, the hinges and the observation pane are all proved with the leaf as one doorset.
The observation pane lets the staff see the person in the cell without opening the leaf, and the pane sits where the staff can see through it from the wing. The pane takes the same proof as the leaf, because a cell door that holds while the pane beside it fails has held nothing.
The hinges on a cell door carry the leaf through every opening, and each hinge carries its share of the weight. A hinge that has worked loose lets the leaf drop a little each month, until the leaf drags and the gap at the top opens wide enough for smoke to pass. The hinges are looked at on every visit, and the doors that guard a hospital take the same care with their leaves, as the hospital security doors guide shows.
The prison order: one list, every leaf named
The prison door order is one list, with a line for every door in the building and the leaf, the period, the lock and the closer beside each one, so the door that arrives is the door that was ordered. A list that names one leaf for the whole building leaves the fitter to guess which part takes which rating, and a leaf fitted to the wrong part guards the wrong thing.
Read the price beside the list before the order goes out, leaf by leaf, so every lock, closer and seal carries its own figure and nothing is left to guess. What each step up the scale adds to the price is worked through in the security door cost factors guide, and the columns the list needs are set out in the how to specify security doors guide.
The officer on the round tries each door in turn, from the custody suites through the wings and the public route to the plant room, and a leaf that will not shut is noted before the round moves on. Each fault goes on the record beside the door it belongs to, with the part and the day it was found, so the repair is ordered while the fault is still small. The fire door inspection checklist names what each visit should look for, and the security door maintenance checklist covers the doors that must hold both fire and forced entry.
| Position | Door | Period | What to check |
|---|---|---|---|
| Cell | Steel leaf | FD60 | Leaf, lock, pane |
| Wing | Fire leaf | FD60 | Leaf, closer, seals |
| Public route | Fire leaf | FD60 | Leaf, bar, closer |
| Custody suite | Fire leaf | FD30 | Leaf, lock, seals |
| Plant room | Fire leaf | FD60 | Leaf, seals, gap |
A prison door holds only as long as the people behind it and the way out beside it, so the period, the lock and the release must all sit on the same list.
What period should a prison door carry?
FD30 or FD60 to EN 1634-1, with the letters beside the number naming what the doorset held back, and the part of the building behind the leaf decides the period.
Can a cell door hold fire and hold a person in?
Yes, when the leaf, the frame and the lock faced the test together, so the one doorset carries the proof for both jobs.
Do prison doors need panic hardware?
Yes, a panic bar to BS EN 1125 sits on the doors on the way out, at least 60 percent of the leaf wide, so one push opens the leaf for the people behind it.
What happens to a prison door when the power fails?
The answer is written beside each door on the schedule: a leaf on an escape route opens, while a leaf that guards a cell stays shut.
Who checks the prison doors?
The officers who run the wing walk the round that covers every door, and each visit is written into the record the building keeps.