ArxBridge
Fire Door Rules for Bookmakers
A bookmaker holds cash, slips and records behind its leaves through the day, so each door takes the fire period the room behind it demands, FD30 or FD60.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A bookmaker is a waiting area, a counter and a cash office behind one entrance, and the fire rules for the building follow the rooms behind each leaf. The counter holds the cash the queue hands over, the cash office holds the takings and the slips, and the back office holds the keys and the screens.
EN 1634-1 is the test that counts the fire minutes on a bookmaker leaf, and the period is the count. FD30 names thirty minutes and FD60 names sixty, and the letter beside the minutes says what the leaf held back, with E for flames alone, EW for flames with some heat held back and EI for flames with the heat held back as well.
A bookmaker follows the same rules as any other high street shop that takes cash at a counter. The fire door regulations retail guide covers the fire rules for a shop, which holds a queue in front of a counter the same way a bookmaker does, and the fire door regulations offices guide covers the rooms a bookmaker keeps behind its shop front.
- FD30 / FD60Fire periods to EN 1634-1
- Cash officeWhere the period rises
- Sa / S200Smoke ratings to BS EN 1634-3
- One listEvery bookmaker door named
Five rooms behind one betting shop front: the period each room takes
Five parts make up a bookmaker, and the period follows what each part holds. The entrance holds the queue coming in, the counter holds the cash the queue hands over, the cash office holds the takings and the slips, the back office holds the keys and the screens, and the plant room keeps the building running.
FD60 sits on the cash office, the back office and the plant room, because the takings, the keys and the boards behind those leaves need sixty minutes before the fire reaches them. FD30 sits on the entrance and the counter, because the queue on that route can move to the street in far less time than thirty minutes.
Every opening gets its own line on the order, with the leaf and the period written beside it, so no leaf is hung on guesswork and no room ends up with a leaf that holds fire for the wrong length of time. The fire door regulations supermarkets guide covers the fire rules for a shop that takes cash at tills all day, and the fire door regulations commercial buildings guide covers the parts the buildings share.
| Position | Leaf | Period | What to check |
|---|---|---|---|
| Cash office | Steel leaf | FD60 | Leaf, lock, seals |
| Back office | Steel leaf | FD60 | Leaf, lock, seals |
| Plant room | Steel leaf | FD60 | Leaf, lock, seals |
| Counter | Glazed leaf | FD30 | Leaf, glass, closer |
| Entrance | Glazed leaf | FD30 | Leaf, glass, closer |
What FD30 and FD60 hold back in a betting shop
A fire period is a count of minutes from the test, and the doorset that earns it is the leaf, the frame, the fixings and the lock proved together. The report names the period the doorset holds, and the order writes that period beside the leaf, so the leaf that arrives is the leaf the room asked for. The fire door certification guide names what the report behind the period must hold.
Some leaves in the shop must hold fire as well as forced entry, and one doorset carries both proofs in one report. EN 1634-1 counts the fire minutes, LPS 1175 Issue 8.2 of September 2024 names the forced entry grade in B3, C5 and D10, and the fire and security doors dual certification guide shows how the pair is proved on the same leaf.
The cash office, the back office and the plant room: FD60 behind shut leaves
Behind the cash office leaf sit the takings and the slips the shop runs on, so the leaf takes FD60 and stays shut whenever no one is counting cash. Sixty minutes is the hold the room asks for, because a fire that reaches the cash office takes the takings and the records the shop cannot replace.
The back office holds the keys, the screens and the paperwork, and its leaf takes FD60 for the same reason, because the keys and the system behind it are what the shop opens with each morning. A leaf that stands open through the day holds nothing back, so the back office leaf is shut each time the last person leaves the room.
The plant room holds the boards and the equipment that keep the lights and the screens running, and its leaf takes FD60 because the boards behind it feed the whole shop. The plant room fire doors guide covers the leaves of a plant room in full, and the plant room door requirements guide covers the doors that guard the plant.
The counter and the entrance: FD30 on the route the queue uses
The queue stands at the counter and moves to the street through the entrance, so both leaves take FD30. Thirty minutes is more than the queue needs to leave, and the route behind the leaves is short, with the street at the end of it.
Where the route serves a crowd, the leaves on the way out take a bar proved to BS EN 1125, and the bar runs across at least 60 percent of the leaf width, so a person who reaches the leaf in a crowd can open it with one push. The panic hardware guide sets out what the bar must do for a crowd that pushes against the leaf, and the emergency exit doors guide covers the leaves on the way out.
A glazed panel in the counter leaf lets the staff see the queue without opening the leaf, and the pane is proved with the leaf round it, with the glass, the bead and the fixings named together in the report. The fire door vision panels guide covers the panels a fire leaf can carry, and the steel vs timber fire doors guide sets the two leaf materials beside each other.
Smoke on the route: Sa and S200 beside the period
People on the way out meet smoke before they meet flame, so the leaves on the route carry a smoke rating beside their fire period. BS EN 1634-3 names the two ratings, Sa for smoke at room temperature and S200 for smoke at 200 degrees, and the smoke control doors guide works through how the route leaves keep the smoke back while the queue moves past them.
Closers, seals and gaps on betting shop doors: what the period rests on
The leaf is hung with a 4 mm gap round it, and a gauge measures the gap so a hinge or a frame that has shifted shows up as a gap that has grown. The seal in the groove swells when the heat reaches 200 to 250 degrees and closes the gap, and paint over the seal stops it swelling, so the seal is looked at as well as the gap.
A fire door closer takes at least EN 3, the smallest power size the rules allow on a fire door, and the leaf must shut on its own from any angle it is opened to. BS EN 1154 names the power sizes from EN 1 for a leaf 750 mm wide and 20 kg in weight to EN 7 for a leaf 1,600 mm wide and 160 kg in weight.
Hinges to BS EN 1935 carry the leaf through its working life, with grade 13 proved for 200,000 cycles at 120 kg and grade 14 proved for 200,000 cycles at 160 kg. The fire door hardware guide names what the hardware on a fire leaf must do, and the fire door closers guide covers the closers in full.
The force to open a leaf on the public route stays below 30 N for the first 30 degrees and below 22.5 N beyond them, to BS 8300 and Approved Document M, so a person in the queue can push the leaf open without help. Signs on each fire door say what the leaf is, and the fire door signage guide names what each sign must say.
Getting the queue out: the way from the counter to the street
When the alarm sounds, the queue must find the street without knowing the building, so the route is signed at every turn and nothing stands in it. Chairs, tables and displays are kept off the route, and the entrance leaf opens to one push from whoever reaches it first.
Martyns Law puts premises in tiers by the number of people they hold, with one tier for 200 to 799 people and a higher tier at 800 and above, and the Martyns Law guide for premises sets out what each tier asks for. A bookmaker that holds 200 or more people sits in a tier the guide covers, so the route out is planned with that tier in mind.
A back office leaf that is held open through the working day needs a hold-open device proved to BS EN 1155, which lets the leaf go on its own when the alarm sounds. A leaf wedged open with a chair has no period at all while it stands open, so the wedge is never the device that holds a fire leaf.
The betting shop order: every leaf, its period and its proof
Every opening in the shop gets a line on the order, with the leaf, the period, the lock and the closer written beside it. A single leaf named for the whole shop leaves the fitter to guess, and a leaf in the wrong room holds fire for the wrong length of time.
The order is checked leaf by leaf before it is signed, because a closer ordered after the doorset arrives is a closer that holds the job up, and a leaf with no line beside it is a leaf no one can check when it arrives. The how to specify security doors guide lists what the order must hold for every door.
A leaf that drags on the floor, a closer that leaves the leaf standing open or a seal that has been painted over are the faults that show first, and each one is written against its own door on the day it is found, so the fault is put right before the leaf is asked to hold. The fire door inspection checklist names what to look for on each leaf, and the fire door maintenance guide covers the work that keeps the leaves holding.
The period on a bookmaker leaf means nothing on its own, so the leaf, the closer and the seal are ordered together and checked together against the room behind the leaf.
What period should a bookmaker fire door carry?
FD60 for the cash office, the back office and the plant room, and FD30 for the entrance and the counter, each proved to EN 1634-1.
Can one leaf hold fire and forced entry?
Yes, where one doorset carries its fire minutes and its forced entry grade in the same report, so the period and the grade sit beside the same leaf.
Do bookmaker fire doors need a smoke rating?
Yes, the leaves on the route carry Sa or S200 to BS EN 1634-3 beside their period, because the people on the way out meet smoke before they meet flame.
Who checks the bookmaker fire doors?
The shop manager keeps the door list and looks over the leaves in turn, so a leaf that will not shut or a seal that has been painted over is found before the leaf is asked to hold.
What happens when a fire door will not shut?
A leaf that will not shut is written up against its own door the day the fault is found, and the shop does not wait for the next look round before the leaf is put right.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.