Certified physical security

ArxBridge
Steel door sample in a security test frame with an assessor in a UK test laboratory

ArxBridge

Community Centre Security Doors

A community centre guards halls, meeting rooms and offices, so each leaf takes the grade the room behind it demands, from foyer to plant room.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A community centre is a hall, a set of meeting rooms and offices behind one entrance, and the doors between those parts decide what stays where it belongs. The hall holds the crowds, the meeting rooms hold the groups, and the offices behind them hold the records, the keys and the equipment, so each door takes its proof from the room behind it.

LPS 1175 sets the grade on a community centre door, and the category follows what sits behind the leaf. Issue 8.2 of September 2024 names the three categories B3, C5 and D10, at three, five and ten minutes. The entrance takes the lowest of the three, and the hall, the meeting rooms and the offices take the middle one.

A community centre follows the same rules as any other public building. The fire door regulations commercial buildings guide covers the parts the buildings share, and the leisure centre security doors guide covers the doors of a sports centre, not a community hall. The centre order names every door, with the grade and the lock beside each one, so the door that arrives is the one its room asked for.

  • LPS 1175 B3 / C5 / D10Forced entry grades to Issue 8.2
  • HallsWhere the grade rises
  • FD30 / FD60Fire periods to EN 1634-1
  • One listEvery centre door named

Halls, meeting rooms and offices: one community centre, three grades

Three parts make up a community centre, and the grade follows what each part holds. The hall holds the crowds, the meeting rooms hold the groups, and the office holds the records and the keys, so each part takes the doors its work demands.

The entrance leaf opens for every visitor who arrives and shuts behind them on its own, because a leaf left standing open guards nothing. The hall leaf stands shut through the day, and it must hold against the attack the equipment behind it invites.

The order is written from a list that names every opening, the leaf it takes and the grade beside it, because a leaf with no line on the list may turn up in the wrong meeting room.

The entrance and the foyer: the leaves everyone passes

The entrance leaf must open for every visitor who arrives and hold an intruder out once the centre shuts, so the leaf, the frame and the lock are proved as one doorset, and the test report names all three.

A closer pulls the entrance leaf shut after every visitor who passes, because a leaf left standing open guards nothing. The closer is set so the leaf comes home without a slam, and the pull is checked by opening the leaf and seeing it shut on its own.

A glazed panel in the entrance leaf lets the foyer see who waits outside before the leaf opens, and the glass takes the same proof as the leaf round it. What the pane adds to the order is worked through in the fire rated glass cost guide, and the bead and the fixings that hold it are named in the test report.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Halls and meeting rooms: the doors behind the foyer

Behind every hall door sit the chairs and the equipment the centre runs on, and the leaf that guards them takes the grade the value behind it demands. C5 suits the hall, because the equipment behind it justifies the minutes it takes to break through, and the leaf must hold until the alarm is answered.

Only the centre team holds the key to the hall stores, because visitors must never pass them alone. The hall leaf takes C5, the meeting rooms beside it take C5, and the entrance takes B3.

The hall leaf shuts out the sound of the foyer as well as an intruder, so the meeting rooms stay quiet while visitors move through. The seals round the hall leaf and a closer that brings it home after every person through do that work.

A leaf on the hall can carry both proofs, because the hall needs fire held back and an intruder held out. The fire proof comes from EN 1634-1 in minutes and letters, E, EW and EI from 30 to 120, and the forced entry proof comes from LPS 1175 in B3, C5 and D10. The two tests run on the same leaf, frame and seals, so one report holds both proofs, and how one doorset carries the pair is shown in the fire and security doors dual certification guide.

The office and the stores: where the records and the equipment sit

The office holds the records and the keys, and the leaf that guards it takes the grade the value behind it demands. C5 suits the office leaf, because the records behind it justify the minutes it takes to break through.

The stores beside the office hold the chairs, the tables and the equipment, so their leaf takes the same care. C5 suits the stores leaf, and its lock takes the same key as the office, so one key opens both doors for the staff who work there. What breaks a rating once a door is fitted is named in the keeping an LPS 1175 rating valid guide.

On drawings drawn before Issue 8 the same three categories are called SR2, SR3 and SR4, so the order carries the old name beside the new one for the fitter who reads them.

Plant rooms and the kitchen: the doors that keep the centre running

The plant room holds the boards and the plant that keep the centre running, and its leaf takes C5, because the value behind it justifies the minutes it takes to break through.

The kitchen beside the hall serves the groups that meet there, so its leaf must be wide enough for trolleys and trays, with a closer that pulls it shut after each meal. The kitchen leaf takes C5, because the equipment passing through it is worth the minutes it takes to break through, and the leaf, the frame, the fixings and the lock are proved together as one doorset, with the report naming the grade it holds.

A kitchen leaf held open through the working day needs a hold-open device proved to BS EN 1155, which shuts the leaf on its own the moment the alarm sounds.

The leaf is hung so a 4 mm gap runs round it, and the gap is checked with a gauge on every round, because a gap that has widened since the last visit points at the hinge or the frame. The seal in the groove swells when the heat nears 200 to 250 degrees and closes the gap, unless paint over the seal holds it back.

Getting a full hall out: community centre escape routes

When the alarm sounds in a community centre, the people in the hall take the route the signs point to, and the way must be kept free of chairs, tables and anything stored against the doors. Each leaf on that route gives way to one push from the person who reaches it first, with the power on or off.

The route doors need a smoke rating as well as a fire period, and BS EN 1634-3 gives it: Sa where the smoke is at room temperature, S200 where it is at 200 degrees. Smoke moves faster than flame, so it reaches the people on the route ahead of the fire, and a seal holds only where it meets the frame all round. How the doors keep smoke back while the crowd moves past them is worked through in the smoke control doors guide.

A community centre is a crowded place, so the physical measures that support the risk assessment are set out in the Martyn’s Law guide for premises. Every leaf on the route must hold as long as the route needs, because a leaf that gives way sooner than its neighbours ends the route with it. The fire door regulations leisure centres guide takes the same care with the visitors in a leisure centre.

Position Door Grade What to check
Entrance Glazed leaf LPS 1175 B3 Leaf, glass, closer
Hall Steel leaf LPS 1175 C5 Leaf, lock, seals
Meeting rooms Steel leaf LPS 1175 C5 Leaf, lock, seals
Office Steel leaf LPS 1175 C5 Leaf, lock, reader
Stores Steel leaf LPS 1175 C5 Leaf, lock, seals
Plant room Steel leaf LPS 1175 C5 Leaf, lock, seals

Locks, keys and the centre team: who opens which door

Staff move from the entrance through the hall to the plant room and back, and each leaf on that route opens for staff and stays shut for the public. A reader sits beside every leaf, and it opens for the cards the list names. The fire door hardware guide sets out what the lock the key turns must do, and the security door locks guide names what the lock on a centre leaf must hold.

What the readers, the releases and the wiring beside a leaf must do is covered in the door entry systems guide.

Each door on the order carries the answer for the night the power fails, so the team knows which leaves open and which stay shut when the supply goes. A leaf with no answer beside it leaves the team guessing on the night the answer matters most.

The community centre order: every leaf on one list

The whole centre order sits on one list, a line for every door with the leaf, the grade, the lock and the closer beside it, so the door that arrives is the door its room asked for. A list that names a single leaf for the whole centre leaves the fitter to guess which room takes which grade, and a leaf in the wrong room guards the wrong thing.

The figures are laid beside the schedule door by door before anything is signed, because a door with no figure beside it still turns up on the invoice, and a lock ordered after the doorset costs more than one ordered with it. The how to specify security doors guide lists what the schedule must hold for every door, and the security door cost factors guide sets out what each step up the grade adds to the figure.

The doors are tried through the week, a few leaves each day, so none goes untried for long: the entrance at opening, the hall before the first group, and the office door at closing. A fault is put down against the door where it was found, on the day it was found, with the part and the date beside it, and the repair is booked while it is still small. The record stays with the centre file, and what the visit should cover is set out in the fire door inspection checklist.

A community centre door holds only as long as the halls behind it and the foyer beside it, so the grade, the period and the lock must all sit on the same list.

What grade should a community centre door carry?

B3, C5 or D10 to LPS 1175. The hall takes the middle category on the site, the meeting rooms take the middle one, and the entrance takes the lowest, so the grade follows the room behind the leaf.

Can one leaf hold fire and forced entry?

Yes, where the same doorset passed the fire test and the forced entry test together, so one report holds the two proofs.

Do community centre doors need access control?

Yes, the doors behind the foyer take a reader beside the leaf, so staff can open them and visitors cannot pass after hours.

What period should a community centre door carry?

The centre order lists the period leaf by leaf, and each one is proved to EN 1634-1. A hall leaf holds fire longer than a leaf on the public route, so the minutes on the order follow the room, not the building as a whole.

Who checks the community centre doors?

The centre manager tries the doors a few at a time through the week, and each fault is written against its own door on the day it is found. The record of the round stays with the centre file.

Specifying doors for a community centre?Send the door list and the grade each room must hold for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.