Fire Door Regulations for Bowls Clubs
A bowls club keeps a quiet green beside a clubhouse, a bar and changing rooms, so each leaf takes the fire period its room needs, FD30 in front and FD60 behind.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A bowls club gives its entrance, its clubhouse, its changing rooms and its bar an FD30 leaf, and its kitchen, its back office and its plant room an FD60 leaf. The front rooms hold fire back for 30 minutes, and the back rooms hold it back for 60, because the heat and the papers behind them ask for the longer hold.
Under EN 1634-1 a doorset is tested against fire and given a period in minutes, from FD30 up to FD120. The letter that follows the number says what the leaf kept out, E where flame alone was kept out, EW where flame and part of the heat were kept out, and EI where flame and heat together were kept out. A leaf marked FD30 keeps flame out for 30 minutes, and a leaf marked FD60 keeps it out for 60 minutes.
A bowls club runs its day on the green outside and its evening in the clubhouse, which sets it apart from a cricket club where the day runs on the square beside a pavilion. No machine stands in place of a bowl, so the club is not an arcade, and no caller runs the evening, so it is not a bingo hall. The lane venue is covered in the fire door regulations for bowling alleys guide, the machine hall in the fire door regulations for arcades guide, and the called session in the fire door regulations for bingo halls guide, while this guide stays with the green, the clubhouse and the bar.
- FD30 / FD60Periods to EN 1634-1
- GreenWhere FD30 guards the clubhouse
- KitchenFD60 behind the cookers
- One listEvery club leaf named
Seven rooms in a bowls club: the period each leaf takes
The club holds seven rooms, and the period on each leaf follows what its room holds. The seven rooms are the entrance, the clubhouse, the changing rooms, the bar, the kitchen, the back office and the plant room.
FD30 sits on the entrance, the clubhouse, the changing rooms and the bar, because all four stand where members and visitors pass through the day and the evening. FD60 goes on the kitchen, the back office and the plant room, because the heat, the papers and the plant behind those leaves ask for sixty minutes rather than thirty.
| Room | Period | Grade | What to check |
|---|---|---|---|
| Entrance | FD30 | B3 | Leaf, closer, seals |
| Clubhouse | FD30 | B3 | Leaf, closer, vision panel |
| Changing rooms | FD30 | B3 | Leaf, closer, seals |
| Bar | FD30 | B3 | Leaf, closer, gaps |
| Kitchen | FD60 | C5 | Leaf, closer, seals |
| Back office | FD60 | C5 | Leaf, closer, gaps |
| Plant room | FD60 | C5 | Leaf, closer, seals |
Where the club wants a leaf that also resists forced entry, the fire period and the grade are proved on the same doorset, so one report holds both and the order names both together. How the two proofs sit on one leaf is named in the fire and security doors dual certification guide.
What FD30 and FD60 hold back in a bowls club
FD30 keeps flame out for 30 minutes and FD60 keeps it out for 60, and the letter after the number says whether the heat was kept out with the flame. E marks a leaf that kept out the flame alone, EW marks a leaf that kept out the flame with part of the heat, and EI marks a leaf that kept out the flame with the heat as well.
The longer period belongs where a fire would start hot and grow fast, and the shorter period belongs where the room opens onto the way out. The kitchen, the back office and the plant room take FD60 for that reason, while the entrance, the clubhouse, the changing rooms and the bar take FD30. The fire door certification guide names what proof a leaf must carry before the club accepts it.
The FD60 rooms: kitchen, back office and plant room
The kitchen holds the cookers and the gas that feed teas between matches, so FD60 sits on its leaf and the leaf stays shut while the cookers are hot, because a fire that starts at a cooker grows fast and the clubhouse beside it holds members. A kitchen that serves meals through the day is covered in the fire door regulations for restaurants guide.
The back office holds the membership lists, the fixture lists and the papers that run the club, so FD60 sits on its leaf as well, and the leaf stays shut when the room is empty, because the papers behind it would feed a fire and the club would lose the records it runs on. The till is counted in the back office too, behind the same FD60 leaf, once the bar shuts.
The plant room holds the boards and the equipment that keep the water hot and the lights on, so its leaf takes FD60. What a leaf on that room must do is named in full in the plant room fire doors guide, and the leaf stays shut because the boards behind it feed the whole club.
Entrance and clubhouse: FD30 where members arrive for the day and the evening
Members arrive at the entrance with bowls bags over their shoulders, and visitors follow them in for a drink in the clubhouse before the evening match, so the entrance leaf takes FD30 and stands on the way out as well as the way in. The leaf opens to members and their guests while the session runs, and it must open freely when the clubhouse empties.
BS 8300 with Approved Document M puts the push on the entrance leaf below 30 N through the first 30 degrees of swing and below 22.5 N beyond that, so the leaf opens for a member carrying a bowls bag. When the alarm sounds while visitors new to the clubhouse are still in the bar, the route to the car park is signed at every turn and nothing stands on it.
The bar takes the takings of the day behind an FD30 leaf that stays shut once the last drink is served, and the till is counted behind that shut leaf. A venue that counts cash through the night is covered in the fire door regulations for casinos guide.
Changing rooms and bar: FD30 beside the green
The changing rooms take FD30, because players leave bowls bags, phones and wallets on the benches there while the match runs on the green, and the leaf stays shut while the rooms are empty.
The clubhouse leaf carries a small vision panel, so a member can see whether the bar is busy without opening the leaf. What a pane in a fire leaf must hold is named in the fire door vision panels guide.
Where the way out serves more than 60 people, the leaves on it need a push bar proved to BS EN 1125, and the bar runs across no less than 60 percent of the leaf width. One push from a member with a crowd behind them throws the leaf open, and the bar works with the supply on or off. The panic hardware guide names what the bar must do under a crowd, and the emergency exit doors guide covers the leaves on the way out.
Members gather at the bar after a match, with the green in view through the clubhouse windows, so the leaf takes FD30 and stays shut while the bar is empty.
Smoke in the clubhouse: Sa and S200 beside the period
Smoke reaches the clubhouse before flame does, so each leaf needs a smoke seal beside its period, and the seal is proved to BS EN 1634-3. Sa marks a leaf that holds smoke back at room temperature, and S200 marks a leaf that holds it back at 200 degrees, so the mark on the order names which smoke the leaf was proved against.
The corridor from the clubhouse to the entrance carries the smoke of a fire in the kitchen or the plant room, so its leaves take smoke seals beside their period. Where a smoke seal sits beside a fire period is named in the smoke control doors guide.
Closers, seals and gaps: what holds the club period in place
The closer that pulls the leaf shut after each member holds a proof to BS EN 1154, where EN 1 is the smallest power size the standard names and no fire leaf takes a power size below EN 3. A closer too weak for the leaf leaves it ajar, and a leaf left ajar holds no period at all.
The intumescent seal round the leaf swells when the heat reaches it, and the swell closes the gap round the leaf edge. The seal starts to expand at around 200 to 250 degrees, and how the seal is fitted and what it must hold is named in the intumescent seals guide.
The gap round a fire leaf is 4 mm, and it is measured round the leaf edge and the head, not guessed by eye. Where the gap is measured and what a wide gap costs the leaf is named in the fire door gaps guide.
The club leaves hang on hinges proved to BS EN 1935, grade 13 through 200,000 cycles with a leaf of 120 kg and grade 14 through the same cycles with a leaf of 160 kg. What each piece on a fire leaf must carry is named in the fire door hardware guide.
The bowls club fire door order: every leaf, its period and its proof
The whole order sits on one list, and every opening has a line of its own that names the leaf, the period, the seals and the closer beside it. A leaf with no line of its own may end up hung where it does not belong, and an FD60 leaf on the changing rooms would hold for 60 minutes where 30 would do.
Each month the club secretary takes the door list round the club and tries each leaf in turn, and the closer, the seals and the gap on each leaf are looked at as the leaf is tried. A leaf that will not shut, a seal that is torn and a gap that has grown are noted on the list, and the fire door inspection checklist names what the walk round the club should cover.
For the larger sports hall beside a club, the fire door regulations for leisure centres guide covers the fire rules there, and the fire compartmentation guide names how the rooms of the club are held apart from each other. What keeps a leaf holding its period once the order is in is named in the fire door maintenance guide.
Each leaf on the order is read through once more before the order is signed, and the proof for every leaf is checked against the list before the order leaves the club.
The period on a bowls club leaf follows the room behind it, so the leaf, the closer and the seals are ordered together and checked together against the green and the takings behind the leaf.
What period does a bowls club entrance take?
FD30 to EN 1634-1, which holds flame back for 30 minutes, because the entrance stands on the way out through the day and the evening.
What period does the kitchen take?
FD60 to EN 1634-1, which holds flame back for 60 minutes, because the cookers behind the leaf ask for a longer hold.
What period does the plant room take?
FD60 to EN 1634-1, which holds flame back for 60 minutes, because the plant room boards feed the lights and the hot water of the whole club.
What gap does a fire door leaf need?
A gap of 4 mm round the leaf edge and the head, because a wider gap lets flame and smoke slip past before the period runs out.
Who checks the bowls club fire doors?
The club secretary takes the door list round the club each month and tries the fire leaves in turn, looking at the closer, the seals and the gap on each leaf.