A factory door works harder than most doors in a building. Forklifts cross the floor all day, pallets knock against leaves, dust settles into locks and closers, and the doors on escape routes and compartment lines must still close, seal and hold when the alarm sounds.
The order comes from the risk on each opening. A personnel door on the production floor faces forklifts and shift changes, a stores door faces stock moving in and out, and an office door faces visitors and staff, and each one needs a rating, a period and hardware to fit the opening.
The rating, the fire period, the hardware, the gates and the records all sit inside one schedule, and a plain order gets the right doors on the right openings.
- LPS 1175 B3 / C5 / D10Forced entry ratings, three, five and ten minutes
- PAS 24Enhanced security doorset standard
- EN 1627 RC1-RC6Resistance classes for windows, doors and shutters
- FD30 / FD60Fire resistance periods tested to EN 1634-1
Production floors, stores and offices: where a factory puts its security doors
A factory divides into parts that move people and stock in different ways, and each part puts its security doors in a different place. The production floor holds machines and the people who run them, the stores hold the stock that waits for a bay, and the offices hold the staff who plan the work.
Doors on escape routes and doors on compartment lines do different jobs, and every part of the factory holds both kinds. An escape door has to open at once so staff can leave, while a compartment door has to stay shut so fire stays on one side of a wall. One leaf can do both jobs, but the test evidence has to name both for the assembly that will be fitted. Our dual certification guide works through how the two proofs sit on one doorset.
Forklifts, dust and daily use: the doors that take the shift
Forklift traffic damages a factory door faster than anything else in the building. A leaf dented by a truck, a hinge bent by a pallet, a seal torn off by a load all break the rating the doorset was given, and the door needs repair or replacement, not a note in the file. The inspection round should look for that damage first.
Dust gets into the parts a factory door depends on. A closer clogged with dust cannot pull the leaf shut, and a dusty lock will not turn. The security door maintenance checklist sets out what the round looks for.
A hinge that sags leaves a gap the seals cannot close, and factory leaves sag fast when the hinge grade is wrong. BS EN 1935 proves hinges by cycles and load: grade 13 is proved for 200,000 cycles at 120 kg, and grade 14 for the same cycles at 160 kg. A leaf that outgrows its hinge grade drops until it drags, and a dragging leaf will not latch.
Closers follow BS EN 1154, which sets power from EN 1 to EN 7. EN 1 suits a 750 mm leaf weighing 20 kg, and EN 7 suits a 1,600 mm leaf at 160 kg, and a fire door takes no less than EN 3. A closer set too weak leaves the door open, and one set too strong breaks the access rules. The finish decides how long the leaf lasts in a dusty hall. Our powder coating versus galvanising guide compares the two finishes for steel in daily use.
Reading the rating on a factory order: B3, C5 and D10
LPS 1175 gives a doorset three, five or ten minutes against hand tools. Against screwdrivers, pliers and hand saws, three minutes of holding earns B3. Against crowbars, drills and chisels, five minutes earns C5. Against sledgehammers, disc cutters and jigsaws, ten minutes earns D10. Issue 8.2 of LPS 1175, dated September 2024, carries the current labels; older drawings still show SR2, SR3 and SR4, which read as B3, C5 and D10.
Match the rating to the opening, not to the building. A staffed entrance faces less risk than a rear door onto a yard nobody watches after hours, so walk round the outside and note every door a person can reach, then set each one by the attack it could face. One rating for every door wastes money where the risk is low and leaves the risky doors short.
PAS 24 covers the enhanced security doorset, and a schedule that names PAS 24 beside an LPS 1175 rating names two proofs for the same door, so each needs its own test report. EN 1627 grades windows, doors and shutters from RC1 to RC6. The LPS 1175 versus PAS 24 guide compares the two routes, and the LPS 1175 page sets out the ratings in full.
The personnel door beside the shutter: escape and access in one leaf
Every loading bay needs a personnel door beside the shutter, so nobody has to lift a shutter to walk out. Nobody should have to open the bay just to escape, and the personnel door beside it wants specifying with the shutter, while the order is still open. Our loading bay doors guide covers bay doors in full.
A shutter on a compartment line has to hold fire as well as close the opening. A fire rated roller shutter carries its own test report under EN 1634-1, covering guides, barrel and motor. The fire rated roller shutters page explains the proof, and the roller shutter regulations guide covers the rules that govern one.
Unless the fire strategy names it as one, a shutter is not an escape door. On alarm the shutter closes through a hold-open device to BS EN 1155, and that release belongs on the schedule. A wide opening through a compartment wall takes a sliding fire door, with the leaf running on a track and closing on alarm. The fire rated sliding doors guide explains how one is proved.
Forklifts, dust and the daily cycle: the door that takes the shift
A factory door works harder than most doors. Forklifts pass through all day, dust settles on the hardware, and the leaf must take the knocks of the working day and still shut on its own. The door that fails on one of those jobs leaves the production floor open to the yard.
Production floors, stores and offices each ask for a different door, and the grade follows what the room holds. A door proved to LPS 1175 carries B3, C5 or D10, naming three, five or ten minutes against the tool set for its category, under Issue 8.2, dated September 2024. A store that holds valuable stock takes a higher grade than an office corridor, because the threat follows the goods behind the door.
The personnel door beside the shutter is the door staff use on foot, and it must open for them and shut behind them without anyone touching it. Staff should walk through on foot beside the shutter, so the shutter opens only for vehicles, and the force to open the personnel door must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M. The rules a powered shutter must meet are set out in our roller shutter regulations guide.
One factory doorset can carry two duties at once, fire and forced entry, and each proof needs its own test on the same doorset. The fire proof comes from EN 1634-1 and the forced entry proof from LPS 1175, and a single test report proves only one of them, so the order must name both. The dual certification guide works through the two proofs on one leaf.
The yard gate and the barrier: closing the vehicle line
Access control across a factory site must follow the shift, so a card that works for the morning team stops working when the shift ends. A pass that still works after its holder has left is a door left open, so it must be stopped on the system the same day. The record should name who holds each card, and a card that is stopped must stop working everywhere at once.
The factory yard takes a different line. Gates and barriers close the gaps a vehicle could drive through, and the spacing between them matters as much as the rating. Vehicle ratings are proved to ISO 22343-1, which supersedes PAS 68:2013, with test vehicles from a 1,500 kg car to a 30,000 kg truck at 48, 64 or 80 km/h, and the rating on the order should match the vehicle the approach could bring.
ProtectUK sets the spacing on the line, with no more than 1,200 mm clear between bollards and a minimum height of 500 mm. The ratings in full are set out in our ISO 22343 vehicle security barriers guide, and the rated options for the gate line are covered in our anti-ram gates and barriers guide.
The round walks the production floor, the stores and the yard once a month and looks at every leaf, shutter and gate in turn. A leaf that drags, a shutter that no longer shuts, or a gate that drags on its hinges each gets written down the same day, with the opening and the fault beside it, so the repair follows the fault and the factory never stands open.
| Opening | Door | Rating | What to check |
|---|---|---|---|
| Personnel door | Solid security door | LPS 1175 B3 | Lock, hinges, closer |
| Shutter | Roller shutter | FD30 | Motor, safety devices |
| Store | Solid security door | LPS 1175 C5 | Lock, hinges, reader |
| Yard gate | Vehicle gate | ISO 22343-1 | Rating, release, motor |
Name the rating, the reader and the release beside each factory door on the order, so the door that arrives is the door that was tested. The dual certification guide sets out the proofs a doorset needs when it must hold fire and resist attack.
One factory doorset, two duties: fire and forced entry
EN 1634-1 puts the doorset in a furnace and times how long it holds. Thirty minutes of holding is FD30, and sixty minutes is FD60. The letters say what the test measured: E for integrity, EW for limited radiation, and EI for insulation. The EI figure caps the heat on the safe side at 140 degrees Celsius on average and 180 at the hottest point.
The period for each opening comes from the fire strategy and follows the fire load behind the door. An escape door off the floor usually takes FD30, and a door in a compartment wall between two storage areas usually takes FD60. A plant room door or a battery charging area door takes FD60 for the higher fire load behind it. The fire ratings guide explains what each letter and number means.
Smoke fills a corridor long before flame gets there, so a door on a smoke path carries a seal beside its period. FD30S means 30 minutes of integrity with a smoke seal to BS EN 1634-3, to Sa or S200. Keep the gap round the leaf at 4 mm, and intumescent seals swell with the heat, closing the gap at around 200 to 250 degrees.
Access control across a factory site: cards, codes and the shift change
Access control on a factory site decides who can open which door, and when. Cards and fobs suit staff who come and go every day, and codes suit doors that many hands use.
Turnstiles sit on the way in, not on the way out, and they must release when the alarm sounds. A turnstile that holds staff in during an evacuation has failed its first duty, so the release on alarm belongs in the fire strategy. The security turnstiles guide covers readers, fobs and biometrics in the lane.
Panic hardware belongs on the doors that release a crowd, and it must suit the door it sits on. A bar shorter than 60 percent of the leaf leaves part of the crowd pushing on bare steel, and a bar fitted to an untested leaf leaves the doorset with no proven rating. Opening force is capped by BS 8300 and Approved Document M: under 30 N for the first 30 degrees of swing, and under 22.5 N after that. A closer set too strong puts the door outside those limits, so the closer power size belongs on the schedule beside the rating.
Locks and cylinders follow TS 007, where a 1-star cylinder with a 2-star handle gives a 3-star set, but the lock on an escape door must still release in one action, without a key. The keeping an LPS 1175 rating valid guide sets out the changes that void a rating.
The factory yard: gates, barriers and the vehicle line
The yard is where a factory meets the road, and the gates and barriers decide which vehicles get in. Sliding vehicle gates suit a wide entrance that opens many times a day, and a gate that sags on its track leaves a gap a vehicle can push through, so the wheels, the track and the fixings belong on the inspection round. The motor, the controls and the release on alarm all belong on the schedule beside the gate.
Anti-ram gates and road blockers hold the line where a vehicle must be stopped, not just slowed. ISO 22343-1 tests a barrier against a moving vehicle: its mass, speed, angle and how far it travels past the line. The test runs vehicles from a 1,500 kg car to a 30,000 kg truck, at 48, 64 or 80 km/h, and the rating names the vehicle, the speed and the penetration in one string. ISO 22343-1:2023 supersedes PAS 68:2013. The anti-ram gates and barriers guide works through the options. ProtectUK guidance caps the clear gap beside a barrier at 1,200 mm and sets the minimum height at 500 mm.
The factory order: one schedule for the whole site
Write a factory order as a specification, not a catalogue purchase. Put the building and the position in the enquiry, with the fire period and the security rating where needed, and the leaf, frame, glass, beads, seals and hardware as one doorset. Where a door must resist attack as well, ask for the rating on the whole doorset, not on the leaf alone. The how to specify security doors guide runs through the same discipline column by column.
Have the test report, the classification and the hardware schedule travel with the doors, and file them the day the doors arrive. The handover pack should name the inspection routine the site will follow.
| Position | Door | Rating | What to check |
|---|---|---|---|
| Production floor escape route | Personnel door | FD30, B3 | Panic hardware, closer, seals |
| Stores door | Security door | C5 | Lock, hinges, self-closing |
| Office entrance | Security door | PAS 24 | Access control, closer, glazing |
| Loading bay | Personnel door | FD30 | Closer, latch, self-closing |
| Yard entrance | Sliding gate | ISO 22343-1 | Track, wheels, release on alarm |
A factory door that takes a forklift knock and still shuts behind the last person out earns its place on the schedule, and the order must name the rating beside the leaf.
What security rating do factory doors need?
The opening decides. A staffed entrance usually takes B3 or PAS 24, and a rear door onto an unwatched yard usually takes C5, with D10 for doors guarding high value stock.
Do factory doors need panic hardware?
Where more than 60 people use a door, yes. Fit hardware to BS EN 1125, with the bar across at least 60 percent of the leaf.
Can one factory doorset hold a fire rating and a security rating?
Yes, where one doorset is tested for both jobs. EN 1634-1 proves the fire side and LPS 1175 or PAS 24 proves the forced entry side, and both proofs must name the doorset that will be fitted.
What breaks a factory door rating?
A leaf dented by a forklift, a door propped open, a closer that cannot shut the leaf, a seal torn off or gaps over 4 mm. Repair or replace it, and record the work.
Who checks factory doors?
The responsible person under the Order, on the routine the fire risk assessment sets. Each record names the door, the fault, the repair and the date.