Fire Door Rules for Gyms Explained

A gym fills with members who train behind closed doors, so the fire doors must hold the line and let people out: the periods, the routes and the doors named.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Members train with music in their ears and their eyes on the class, so the fire doors must work without anyone thinking about them. The leaf holds fire back for its period, and it opens for people who have never walked the route before.

The period on a gym door follows the room behind the leaf, because the studio, the changing room and the plant room ask different things of the doors that guard them. The order carries the period beside each opening, so the leaf that arrives matches the room it guards.

The rules for the shared parts of a public building are set out in the fire door regulations commercial buildings guide, and the doors that guard a leisure building are worked through in the fire door regulations leisure centres guide. The gym order names every door in the building, with the period and the hardware beside each one.

  • FD30 / FD60Fire periods to EN 1634-1
  • E / EW / EI 30-120What the letters beside the period mean
  • 4 mmThe gap round the leaf
  • One listEvery gym door named

Studios, changing rooms and the routes between them

A gym is three buildings in one: the studios where the classes run, the changing rooms where members arrive and leave, and the public route that joins them. The rules follow those parts, because a door between one part and the next must hold the fire on the side where it started while the people reach the way out.

The studio takes the doors that let a class in and out, and each leaf must open for people who have never seen the building before. The changing room takes the doors that guard privacy, and each leaf must hold fire back where the members leave their things. The route that joins them takes the doors the crowd passes through, and each leaf on it takes the period the escape needs.

The fire strategy is written first, and it names every opening with the door beside it. The order follows the strategy, so each door takes the period its opening demands, and no leaf is ordered without the room it guards behind it.

FD30 and FD60 in a gym: the periods each room takes

Each room in a gym asks a different period of its doors, because the load behind each leaf is different. The store holds the stock in boxes and crates, the studio holds the class on open floor, and the plant room holds the machinery that serves the building, so the period on each door follows the room, not the leaf.

The proof of a fire door is a doorset test to EN 1634-1, and the result comes as minutes with letters. Minutes run from 30 to 120, and the letters beside them say what the doorset held back: flames on their own, flames with some heat, or flames with the heat as well. The order carries the number and the letters together, because the minutes alone say only half of what the test proved.

A longer period takes a heavier leaf, a deeper frame and seals that hold longer, and the price follows the period. A leaf proved for 30 minutes cannot stand on an opening that must hold 60.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

The studio doors: leaves that shut on a class in full swing

The studio doors take the class in and out, and each leaf must open for people who have never touched it before. The release on each leaf throws the latch with one push, and the leaf swings open even when the power has gone.

A glazed leaf lets the instructor see the class through the pane before the leaf opens, and the pane takes the same proof as the leaf, because the leaf and the glass are proved as one doorset. The bead and the fixings the test report names travel on the order beside the glass. The fire rated windows guide covers the windows that share the same wall, and the fire rated glass cost guide works through the cost of the glass itself.

After every class the studio leaf must shut quietly behind the last member out. The closer is set to pull the leaf home without a slam, and the test is to open the leaf and watch it shut on its own. The fire door closers guide sets out the sizes and the fitting of closers, and the acoustic doors guide covers the leaves that keep a studio quiet.

Changing rooms and showers: steam, damp and the leaf that must shut

The changing room holds the members’ clothes, bags and phones while they train, so the doors that guard it take a lock that holds from the inside and opens for the staff. A member must be able to lock the door behind them, and the staff must be able to open it when the room stands empty.

The air in a changing room stays wet from the first shower of the morning, and the leaf and its fixings take that damp through every day of the week. A leaf that swells in the damp leaves a gap at the top, and a gap at the top lets smoke pass over the leaf.

The shower rooms take the same care, because the leaf that guards a wet room must shut as surely as the leaf that guards a dry one. The gap is checked with the gauge on the round, and a leaf that drags is noted beside the door it belongs to. The lock the key turns is covered in the fire door hardware guide.

The public route: the way out for a crowd in kit

The members in a gym follow the route the building gives them, and the way out must be clear when the alarm sounds. Each door on the route opens with one push from anyone who reaches it, because the leaf must open whatever the power is doing.

The route doors take smoke seals proved to BS EN 1634-3, Sa for smoke at room temperature and S200 for smoke at 200 degrees. The seal must meet the frame all round, because smoke moves faster than flame and reaches the people on the route before the fire does. The smoke control doors guide covers the doors that hold smoke back while people move past them.

One route takes one period, and every leaf on it takes the period the route needs. A leaf proved shorter than the leaves beside it is the leaf that fails first, so the route is only as strong as its weakest door. The leaves on a building that fills with a crowd are covered in the fire door regulations stadiums guide.

Position Door Period What to check
Studio Glazed leaf FD30 Leaf, glass, closer
Changing room Fire leaf FD30 Leaf, lock, seals
Stock room Steel leaf FD60 Leaf, lock, seals
Public route Fire leaf FD60 Leaf, bar, closer
Plant room Fire leaf FD60 Leaf, seals, gap

The moving parts: closers, seals and the gap that must hold

Every member who walks through a gym door puts the closer to work, and the leaf must come home behind each one without a slam. BS EN 1154 sets EN 3 as the smallest power a fire door closer may take, and the test is simple: open the leaf and watch it shut on its own. A closer that has lost its pull leaves the leaf standing open after the member has passed.

The leaf needs room to swing and the seal needs a gap it can close, so the gap round the leaf is kept to 4 mm. Heat wakes the intumescent seal at around 200 to 250 degrees, and paint laid over the seal holds it down, so it cannot swell when the fire comes. The gauge comes out on the round, and a gap that has opened or a seal that has come away from its groove is written against the door before the visit ends.

The leaf hangs on its hinges, and the hinges take the whole weight through every opening of the day. When a hinge works loose the leaf drops a little at a time, and the top gap opens until smoke can pass over the leaf. A loose hinge is caught on the round before the leaf starts to drag.

Forced entry in a gym: the grade by the room

The forced entry proof on a gym door is LPS 1175, and the category follows the room behind the leaf. Under Issue 8.2, dated September 2024, B3 holds three minutes, C5 holds five and D10 holds ten, and the grade on the order follows what the room holds.

A studio door takes B3, because the room behind it holds a class and the intruder would try it first. A stock room door takes C5, because the room behind it holds what the gym runs on. The office that holds the takings and the keys takes D10, because it must hold longest. The two ratings sit side by side in the LPS 1175 vs PAS 24 guide, and the keeping an LPS 1175 rating valid guide names what breaks a rating once a door is fitted.

SR2, SR3 and SR4 are the names the same three categories carried before Issue 8, and the name on the order is the name the product was proved under. A door that guards the office takes a higher category than a door that guards a corridor, because the rooms behind them hold different things. Where one standard is named on the order, no other standard is written beside it as its equal, because no published table turns one rating into the other.

One list for the whole gym: periods, leaves and the way out

The gym order is written as a single list, with a line for every door and the leaf, the period, the lock and the closer beside each one. The door that arrives is the door the list names, so no leaf is chosen on the day it is fitted. A list that leaves the period off a line leaves the fitter to guess, and a guess is not a proof.

The quotation is read against the list before the order goes out, line by line, so every leaf, lock, closer and seal is priced. A part left off the price still has to be bought, and fitting it to a door already in use costs more than ordering it with the building. The how to specify security doors guide sets out the columns the list needs, and the security door cost factors guide works through what each step up the scale adds to the price.

The round goes through the studios, the changing rooms, the route and the plant room, and every leaf is tried as the round reaches it. Whatever the round finds is written down at the door, with the part that failed and the day it was found, so the repair is ordered while the fault is still small. The fire door inspection checklist sets out what a visit should cover.

In a gym the period, the release and the closer decide together whether the way out works, so all three sit on the same list before the order goes out.

What period should a gym door carry?

The room behind the leaf decides the period: FD30 or FD60 to EN 1634-1, and the letters E, EW or EI beside the minutes say whether the doorset held the flames alone or the heat as well.

Can one leaf hold fire and forced entry?

Yes, where one doorset faced the fire test and the forced entry test together, so the same leaf carries the proof for both.

Do gym doors need panic hardware?

Yes, the leaf on the way out takes a bar proved to BS EN 1125, running across at least 60 percent of the leaf, so one push opens it for the crowd behind it.

What grade should a stock room door carry?

The grade follows the room: B3, C5 or D10 to LPS 1175, with the stock room taking a higher category than the entrance beside it.

Who checks the gym doors?

The gym manager walks the round that covers every door, and the record of each visit stays with the building file.

Specifying doors for a gym?Send the door list and the period each door must hold for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.