A fire door without a sign is a door people will prop open, push through the wrong way, or leave standing when the alarm sounds. The sign is the part of the doorset that speaks, telling everyone who passes what the door does and what they must do with it.
Signs sit on the door, beside the door and along the escape route, and each one has a job. One says the door must stay shut, one says the way out is this way, and one says what to do when the alarm sounds, so the building empties in order instead of in panic. Without them, the doors are only steel and glass, and the people inside must guess what each one does.
The signs a building needs are covered in the fire door regulations commercial buildings guide, and the Martyn’s Law guide for premises covers the duties a venue carries by the number of people it holds.
- FD30 / FD60Fire resistance periods tested to EN 1634-1
- BS EN 1125Panic hardware for escape routes
- 30 N / 22.5 NOpening force limits
- 4 mmGap round a fire door leaf
The sign on the door: what a fire door sign says
The sign on a fire door says what the door must do, in words a stranger can read in a second. “Fire door keep shut” tells everyone who passes that the leaf must stay closed, and “Fire door keep locked” tells them the door is locked for a reason and must not be forced.
A sign that says nothing is no sign at all. A blank plate, a sign faded by sunlight, or a sign hidden behind a notice board leaves the door unmarked, and a door with no sign is a door people will prop open with a wedge or a chair.
The sign belongs on the door itself, where the hand reaches it, so the person opening the door reads it before the leaf moves. The fire door inspection checklist names what each round should look for, and the security door maintenance checklist covers the doors that must hold both fire and forced entry.
Keep shut, keep clear: the signs that guard the leaf
Two signs guard every fire door: one that keeps it shut and one that keeps it clear. The first tells people not to prop the leaf open, and the second tells them not to stack boxes, chairs or trolleys against it, because a door that cannot shut and a route that cannot be used are the same failure.
A door held open by a wedge is a door with no proof, whatever the sign says. Doors that must stay open through the day take a hold-open device to BS EN 1155, which releases the leaf the moment the alarm sounds, so the sign and the device work together instead of against each other.
The closer pulls the leaf shut after every opening, and it must be sized to the leaf, with no fire door taking less than EN 3 to BS EN 1154. The fire door closers guide covers the sizes and the fitting, and the fire door hardware guide covers the grades and the parts behind a working fire door.
Escape routes and the signs that lead people out
Escape route signs point the way out, and they must be read at a glance by people who do not know the building. A running figure, an arrow and the words “Fire exit” together say more in a second than a paragraph on the wall, and the sign must sit where the eye falls when the corridor turns.
Every turn on the escape route needs a sign, because a corridor that splits without one leaves people guessing. The sign at the split must point to the nearer exit, and the sign at the final door must say the way out is through it, so the route never leaves anyone standing still.
Doors on the escape route must open with a light push, with the force below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M. The fire door regulations schools guide covers the doors in a school, and the fire door regulations hospitals guide covers them for a hospital.
The sign the eye finds first: height, light and the line of sight
A sign works only where the eye finds it at once, so the sign sits at the height the eye reaches first and in the light that falls on the door. A sign set too high is missed by the person hurrying past, and a sign set in shadow reads only when the lights are full on, so the height and the light are checked together on every round.
The running man above the door leads the eye along the route, and the route needs a sign at every turn, because a person who loses the route at a corner stops where the fire is coming from. The signs are set so each one is seen from the last, and a gap between two signs leaves the person standing with no way out in sight.
Pictograms read at a glance where words need a second look, so the sign that must be read in a hurry carries a picture beside its words. The picture should be the one the people in the building know, and the words beneath it should name the door in plain language, because a sign that needs thinking about fails the person who has no time to think.
The fire action notice beside the door carries the plan on the wall, naming what to do when the alarm sounds and where to gather outside. The notice is set beside the door it belongs to, never in the next room, and it is read from the doorway, so the person at the leaf can see the plan without stepping away.
The sign that lies: faded, fallen and the wrong door
A sign that has faded in the sun reads as a pale rectangle with no words in it, and a sign that has fallen from its fixings lies on the floor where no eye finds it. Both are faults of the same kind, because a sign that cannot be read is a sign that is not there, and each is written against its door on the day it is found.
A sign on the wrong door lies worse than a sign that has fallen, because it sends the person through a leaf that leads nowhere. The sign is checked against the door it names on every round, and a sign moved when the room changed its use is moved back or replaced, so the leaf the sign points to is the leaf that opens on the way out.
Coats hung over a sign and posters pasted across it hide the words as surely as fading does, so the leaf and the wall beside it are kept clear. The check looks for what covers the sign as well as for what has faded, and anything hung or pasted over a sign is taken down on the day it is found.
One schedule carries every sign in the building, a line for each sign with the door it belongs to and the words it carries, so a sign that is missing shows as a blank line on the list. The schedule is walked through door by door on every round, and a sign with no line on the list is a sign nobody is checking.
| Sign | Where it sits | What to check | When |
|---|---|---|---|
| Keep shut | On the leaf | Words clear, fixings firm | Each round |
| Running man | Above the door | Seen from the last sign | Each round |
| Fire action notice | Beside the door | Plan matches the room | Each round |
| Keep clear | On the leaf or floor | Nothing stored against it | Each round |
| Do not wedge open | On the leaf | Leaf not wedged | Each round |
How the doors hold smoke back while people move past them is set out in the smoke control doors guide, and what each visit should look for is set out in the fire door inspection checklist. The sizes and fitting for closers are worked through in the fire door closers guide, and the columns the order must hold are worked through in the how to specify security doors guide.
Pictograms, words and the sign that reads at a glance
A pictogram reads faster than words, and it reads for everyone, whatever language they speak. A running figure says exit, a flame says fire, and an arrow says this way, so the sign works for a visitor who cannot read the words beside it.
Words still matter, because a pictogram alone cannot say “keep shut” or “keep clear”. The clearest signs pair the picture with a few plain words, so the message is clear to the person who reads the picture and the person who reads the words. The words must be plain and short, because a sign crowded with small print is a sign no one reads in a hurry.
Signs must be read in the dark as well as in the light, because a fire can take the lights with it. A sign that glows after the lights fail, or a sign lit by the emergency lighting, keeps the route readable when the building goes dark, so the lighting beside the sign belongs on the same check as the sign itself.
Where each sign sits: height, light and the line of sight
A sign works only where it can be seen, and the place it sits decides whether it is read. A sign on the door sits at eye height, a sign above the door sits where the eye goes when the door is shut, and a sign along the corridor sits where the route turns, so the eye meets it before the feet reach the turn.
A sign hidden behind an open door, a notice board or a stack of boxes is a sign that does not exist. The round that checks the doors must check the signs beside them too, and anything that hides a sign must be moved, because a hidden sign leaves the route unmarked.
Light matters as much as place. A sign in a dark corner, under a blown lamp or behind a shadow reads as a blank plate, so the lamp beside the sign must work and the sign must be clean, because dust and grime dim a sign as surely as darkness does.
Signs that fade, fall or lie: the check that keeps them honest
Signs fade in sunlight, peel in damp air and fall when the fixing fails, and a sign that has faded past reading lies about the door it guards. The round that walks the escape routes must look at every sign in turn, and a sign that cannot be read at a glance must be replaced, not cleaned and left.
A sign can also lie by being out of date. A sign that points to an exit that no longer exists, or a sign that names a staircase that is now locked, sends people the wrong way, so every change to the building must be followed by a change to the signs.
Each fault found on the round goes on the record the same day, with the sign, the door and the fault beside it, so the repair follows the fault and the route never stands unmarked. The hotel fire doors guide covers the doors in a hotel, where guests do not know the building, and the fire door regulations offices guide covers them for an office.
Fire action notices beside the door: the plan on the wall
A fire action notice tells everyone in the building what to do when the alarm sounds, in a few short lines beside the door. It says to raise the alarm, to leave by the nearest exit, to shut the doors behind you, and to gather at the assembly point, so the plan is on the wall where the people are.
The notice must match the building it hangs in, because a notice that names the wrong assembly point or the wrong exit sends people the wrong way. When the assembly point moves or the exit changes, the notice must change with it, and every notice in the building must change at the same time.
The notice sits beside the door on the escape route, where the eye falls on the way out, and it must be read in the same light as the signs beside it. The fire door regulations retail guide covers the doors in a shop, and the fire door regulations airports guide covers them for a terminal where travellers do not know the building.
One schedule for the whole building: every sign on one list
Put the order together as one list with a line for every sign in the building, naming the sign, the door and the position beside each one, so the sign that arrives matches the sign that was ordered. A schedule that names one sign for the whole building leaves the fitter to guess which sign goes where, and a guess is not a proof.
Check the quotation against the schedule and tick off each sign as it appears, so the sign, the fixing and the position are all priced. A sign missing from the quotation still has to be bought, and fitting it after the doors are hung takes longer than ordering it with them. The security door cost factors guide lists what each step up the scale adds to the order.
File the test reports with the doors they prove, from the day the doors arrive, so the proof never leaves the leaf it belongs to. The fire door inspection checklist sets out what each round should look for, and the security door maintenance checklist covers the doors that must hold both fire and forced entry.
| Position | Sign | What it says | What to check |
|---|---|---|---|
| Fire door | Keep shut | Fire door keep shut | Fixed, readable, clean |
| Fire door | Keep locked | Fire door keep locked | Fixed, readable, clean |
| Escape route | Fire exit | Running figure, arrow | Lit, visible, arrow right |
| Stair core | Exit route | Fire exit, arrow | Lit, visible, clean |
| Plant room | Keep clear | Fire door keep clear | Fixed, readable, clear |
A fire door sign speaks for the door, so the sign, the position and the light must all sit on the same schedule.
What does a fire door sign say?
It says what the door must do, most often “Fire door keep shut”, so everyone who passes knows the leaf must stay closed.
Where should a fire door sign sit?
On the door itself, at eye height, where the hand reaches it, so the person opening the door reads it before the leaf moves.
What signs does an escape route need?
A sign at every turn, pointing to the nearer exit, and a sign at the final door, so the route never leaves anyone standing still.
Do fire door signs need checking?
Yes, on the round that checks the doors. A sign that has faded, peeled or fallen must be replaced, not cleaned and left.
What is a fire action notice?
A short plan beside the door that says what to do when the alarm sounds: raise the alarm, leave by the nearest exit, shut the doors, and gather at the assembly point.