Certified physical security

ArxBridge
Steel door sample in a security test frame with an assessor in a UK test laboratory

ArxBridge

Steel Door Frames

Steel door frames for security doorsets: the frame that carries the leaf and the rating, with fixings, anchors and the schedule that keeps the proof together.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A steel door is only as strong as the frame that holds it. The leaf takes the attack, the hinges take the weight, and the frame takes both, passing the force into the wall behind it. A leaf proved to the highest rating in a frame that was never proved with it is a doorset that holds only as far as the frame lets it.

The frame is the part of the doorset that never moves, and it is the part the fitter meets first. It is set into the opening, fixed to the wall, and checked for square before the leaf is hung, because a leaf hung in a frame that leans will never shut as it was tested.

The rules a frame must meet are set out in the how to specify security doors guide, and the types of security doors guide works through the doorsets a frame can carry. A frame ordered without the leaf beside it may carry the wrong fixings for the rating the door must hold.

  • LPS 1175 B3 / C5 / D10Forced entry ratings, 3, 5 and 10 minutes
  • BS EN 1935 grade 13 / 14Hinge grades, 200,000 cycles
  • FD30 / FD60Fire resistance periods tested to EN 1634-1
  • 4 mmGap round a fire door leaf

The frame that carries the door: what a steel frame does

A steel frame carries the leaf, the hinges and the lock, and it passes the load of each into the wall. When the leaf is pushed, pulled or struck, the force runs through the hinges into the frame and from the frame into the fixings, so the frame must be fixed to the wall as firmly as the leaf is fixed to the frame.

The frame also carries the proof. A leaf proved with a steel frame holds its rating only when the frame on site is the frame the test report names, because the test covers the leaf and the frame together. A leaf hung in a different frame is a doorset the test never saw.

Steel suits the frame because it holds its shape under load and takes the fixings the hardware needs. The steel versus aluminium security doors guide works through the choice between frame materials, and the steel versus timber fire doors guide covers the choice for a fire door.

Pressed steel, folded steel and the frame that fits the wall

Most steel frames are pressed or folded from sheet steel into a profile with a rebate for the leaf and a stop for the seal. The profile decides how the frame meets the wall, how the architrave sits, and where the fixings go, so the profile belongs on the order beside the leaf.

The frame must fit the opening it goes into, with the wall type deciding the fixing. A frame in a masonry wall takes anchors into the brick or block, while a frame in a stud wall takes fixings into the studs behind the board, and a frame fixed to a wall that cannot hold it will work loose no matter how strong the leaf is.

Where the wall is out of square, the frame must be packed and checked before it is fixed, because a frame that follows a leaning wall leaves the leaf out of square with it. The security door specification mistakes guide names the errors that cost a doorset its proof.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

A frame for a new wall, a frame for an old opening: build-in or bolt-on

A steel frame goes into the wall in one of two ways, and the way follows whether the wall is built or standing. A build-in frame goes in as the wall is built, with the wall built round it and the frame grouted or packed into place, so it suits new work where the opening is still open. A build-in frame holds firm because the wall grows round it, and the frame must be braced square while the wall goes up, or the wall sets the frame out of square.

A bolt-on frame fixes to a finished opening, with anchors or screws through the frame into the wall behind it, so it suits a retrofit where the wall stays and only the door changes. A bolt-on frame needs sound wall each side of the opening, because an anchor set into loose mortar or blown plaster holds nothing, and the number and spacing of the fixings must match the size and weight of the leaf the frame will carry. The fire door hardware guide covers the hinges and the keeps.

The two frames are not the same order. A frame ordered for new work cannot be bolted on later without a different fixing, and a frame ordered for a retrofit cannot be built in without the bracing and the packing the wall needs. Ask whether the wall is built or standing, and put the answer on the order beside the profile. The how to specify security doors guide runs through the columns a schedule should carry, and the security door specification mistakes guide names the errors that cost a doorset its proof.

The depth of the wall and the depth of the frame: a profile that fits both faces

A steel frame has a depth, and the wall has a thickness, and the two must match, so the frame meets both faces of the wall. A frame too shallow for the wall leaves a step on one face, where the plaster or the tile stops short of the frame, and a frame too deep for the wall stands proud of the face, where it catches every trolley and every shoulder that passes. The step or the stand is not a finish problem alone, because a frame that does not meet the wall leaves a gap the fire and the smoke can use.

Measure the wall thickness at several points round the opening, because a wall varies, and the thickest point decides the frame. A wall that runs thick at the base and thin at the head needs a frame sized for the thickest point, with the packing made good where the wall runs thin. The architrave and the plaster line belong on the order beside the depth, so the frame that arrives meets the finish the wall carries. The security door maintenance checklist covers the checks for the frames on the site, round by round.

The profile follows the depth, so a deeper wall takes a deeper profile, and the fixings follow the profile, with the anchors set into the wall behind the frame. The steel versus aluminium security doors guide works through the choice between frame materials, and the thermally broken security doors guide covers the frames that keep heat out of the leaf. Send the door schedule and the wall type behind each opening, and we will price a tested doorset for the building within one working day.

Wall Frame Fixing
Masonry, new work Build-in, depth to match wall Built round, grouted in place
Masonry, standing wall Bolt-on, depth to match wall Anchors into brick or block
Stud wall Bolt-on, depth to match wall Screws into studs behind board
Wall that varies Sized for thickest point Packing made good where thin

Fixings and anchors: the frame held to the wall

The fixings are the part of the frame no one sees once the door is hung, and they are the part that decides whether the frame stays put. Each fixing must bite into solid wall, not into plaster or loose mortar, and the number and spacing of the fixings must match the size and weight of the leaf.

Anchors for a masonry wall spread the load into the brick or block, while screws for a stud wall must reach the timber or steel behind the board. A fixing that holds only the plaster leaves the frame free to move, and a frame that moves lets the leaf drag, so the gap round the leaf opens and the seals stop working.

Check the fixings on the round, and look for a frame that has moved away from the wall or a fixing that has worked loose. The fire door inspection checklist names what each round should look for, and the security door maintenance checklist covers the doors that must hold both fire and forced entry.

An opening out of square still has to take a square frame

Old openings are rarely square. A wall built decades ago leans a little, a lintel sags by a few millimetres, and the head runs out of level across the opening. The frame that goes into it must still stand square, because a frame that follows the lean of the wall leaves the doorset dragging on the floor at one side and short of its seal at the other.

Measure the opening at the head, at the sill and at the middle of each jamb, and write down the smallest width and the smallest height. The smallest reading decides the frame, not the largest, because a frame sized to the largest reading will not fit where the opening runs narrow. For the schedule, the how to specify security doors guide gives the columns each opening needs, and the security door specification mistakes guide points out the errors that can cost a doorset its proof.

Check the opening with a level on each jamb and across the head before the frame is ordered. A jamb that leans takes packing behind the frame to bring it true, and the packing is named on the order beside the profile, so the fitter arrives with it. The fire door inspection checklist lists the checks for each round, and the steel versus aluminium security doors guide weighs the choice between frame materials.

Packers and fixings carry the frame when the wall will not

Where the wall behind the frame is sound, the fixings do the work. Where it is not, the packers do. A packer takes up the gap between the frame and an uneven wall, so the frame stands true and the fixings pull it tight without bowing the profile. A frame pulled tight against a wall that waves in and out will bow with it, and a bowed frame leaves the doorset short of its seal.

Set the packers at each fixing point, not only at the corners. A fixing driven through an unpacked gap pulls the frame towards the wall at that one point, and the frame bends between fixings. Pack each point, drive the fixing, and check the frame for square again before moving to the next point. Hold the gap at 4 mm at the top and on both sides, and the seals can do their work.

Match the fixing to the wall it bites into. Anchors suit masonry, screws suit the studs behind the board, and a fixing in loose mortar or blown plaster holds nothing, whatever its size. The thermally broken security doors guide deals with frames that keep heat out of the doorset. Send the door schedule with the wall type behind each opening, and ask for a tested doorset quotation, and the enquiry checklist asks for the schedule and the wall type with each opening.

Wall condition Packer Fixing
Sound masonry Thin packer to level Anchors into brick or block
Uneven old wall Packer at each fixing point Anchors, frame checked square
Loose mortar or plaster Packer, wall made good first No fixing until the wall holds

The frame beside the leaf: hinges, keeps and the lock

The hinges hang from the frame, and the frame must carry their weight through every opening. Hinges to BS EN 1935 carry the leaf through 200,000 cycles, with grade 13 rated for 120 kg and grade 14 for 160 kg, so the hinge and the frame must be chosen for the weight of the leaf they carry together.

The keep sits in the frame opposite the lock, and it must hold the bolt when the door is forced. A keep fixed with short screws into thin steel will pull out under load, while a keep fixed through the frame into the wall behind it holds, so the screws behind the keep matter as much as the lock in the leaf.

A lock proved to TS 007, with a 1-star cylinder and a 2-star handle or escutcheon making a 3-star set, needs a frame that holds the keep as firmly as the leaf holds the cylinder. The fire door hardware guide covers the grades and the parts behind a working fire door.

Fire and forced entry on one frame: two proofs, one frame

One frame can carry two duties at once, fire and forced entry, and each proof needs its own test on the same doorset. Fire is proved to EN 1634-1 and forced entry to LPS 1175, with B3 holding three minutes, C5 holding five minutes and D10 holding ten minutes, and one report proves only one of them, so both proofs must be named on the order.

A frame on a fire door must hold the leaf shut while the heat builds, with the seals in the frame or the leaf expanding at around 200 to 250 degrees to close the gap. The gap round the leaf must stay at 4 mm, because a wider gap lets fire and smoke past whatever the rating on the leaf says.

Where the escape route runs through smoke, the door takes the S rating on top of its period, with the seal tested for smoke at room temperature and again at 200 degrees. The doors that keep smoke off the escape route while people use it are covered in our smoke control doors guide, and the dual certification guide works through how the fire and forced entry proofs share one leaf.

Gaps, seals and the line the leaf must hold

The gap between the leaf and the frame is the line the doorset must hold. A gap that is even all round lets the seals do their work, while a gap that is wide at the top and tight at the bottom shows a frame that has moved or a leaf that has dropped on its hinges.

Seals sit in the frame or the edge of the leaf, and they must be the seals the test report names. A seal that has come away, hardened with age or been painted over leaves the gap open, and a seal cut back to make a door shut easier is a seal that no longer works.

Measure the gap at the top and both sides with a gauge on every round, and write down what the round found. The thermally broken security doors guide covers the frames that keep heat out of the leaf, and the plant room door requirements guide covers the doors on the rooms that feed a building.

Frames that fail: rust, movement and the wrong fixing

A steel frame fails slowly, and the signs show before the proof is gone. Rust at the base of the frame, where water sits, eats the steel from the bottom up, and a frame that has rusted through at the foot no longer holds the leaf square.

Movement in the wall shows in the frame first. A crack in the plaster beside the frame, a gap opening between the frame and the wall, or a door that starts to catch on the floor each point to a frame that has moved, and a frame that has moved must be refixed before the leaf is adjusted.

The wrong fixing shows when the door is forced. A frame fixed with too few anchors, or anchors set into weak mortar, pulls away from the wall under load, so the leaf, the lock and the keep all move together and the doorset gives way at the frame. The fire door regulations commercial buildings guide sets out the periods for the shared parts of a public building.

One schedule for the whole building: every frame on one list

Put the order together as one list with a line for every frame in the building, naming the profile, the fixings and the leaf beside each one, so the frame that arrives matches the frame that was proved. A schedule that names one frame for the whole building leaves the fitter to guess which frame goes where, and a guess is not a proof.

Read the quotation beside the schedule and mark each line as it is found, so the frame, the anchors and the fixings all appear on the price. A fixing left off the quotation is still needed on site, and ordering it later costs more than ordering it with the frame. The security door cost factors guide shows how the price grows with each step up the scale.

Keep the test reports with the frames from the day they arrive, so the proof stays with the doorset it belongs to. The how to specify security doors guide lists the columns a schedule should carry, and the fire door inspection checklist names what each round should look for.

Position Frame Fixing What to check
Corridor Pressed steel Masonry anchors Square, fixings, gap
Stair core Pressed steel Masonry anchors Square, seals, closer
Plant room Folded steel Stud fixings Fixings, seals, gap
Store Pressed steel Masonry anchors Rust, fixings, gap
Escape route Folded steel Masonry anchors Square, seals, latch

A steel frame holds only as long as its fixings, so the profile, the anchors and the leaf must all sit on the same schedule.

What does a steel door frame do?

It carries the leaf, the hinges and the lock, and passes the load of each into the wall, so the doorset holds as one piece.

What fixings does a steel frame need?

Anchors into masonry or screws into the studs behind the board, with the number and spacing matched to the size and weight of the leaf.

Does the frame carry the fire rating?

Yes, where the leaf and the frame were proved together to EN 1634-1. A leaf hung in a different frame is a doorset the test never saw.

What gap should a steel frame hold?

The gap round the leaf must stay at 4 mm, measured at the top and both sides, so the seals can do their work.

Who checks a steel door frame?

The person who runs the building, on the round that checks the doors. Each fault goes on the record the same day, with the frame named and the date noted.

Ordering this alongside other openings? The security door enquiry checklist lists what to send for each one: location, size, rating and hardware.

Specifying steel frames for a building?Send the door schedule and the wall type behind each opening for a tested doorset quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.