How to keep an LPS 1175 door rating valid after installation
An LPS 1175 rating covers the tested assembly. This UK guide explains the changes that void it, the inspection routine to follow, and the records to keep.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
An LPS 1175 rating belongs to the tested assembly, not to the door alone. It stays valid while the doorset matches the tested build and is maintained to a schedule. New locks, drilled holes, replaced glazing or wall alterations can void it. This guide sets out the inspection routine and the records to keep.
- The ratingApplies to the tested assembly: leaf, frame, locks, glazing and fixings together.
- What voids itUnapproved changes: new locks, drilled holes, replaced glazing, altered walls.
- InspectionA short routine, monthly to annually, checking operation, fixings, seals and glazing.
- RecordsKeep the test evidence, the installation record and every maintenance visit on file.
What the rating actually covers
LPS 1175 tests the product as a complete assembly. The rating on the doorset covers the leaf, the frame, the locks, the glazing and the fixings working together, installed the way the manufacturer describes. It does not rate the lock on its own, the glass on its own, or a leaf hung in a different frame. Change any part of that assembly and the rating no longer describes what is on the wall. Our LPS 1175 guide explains how the ratings are earned.
This is why the paperwork matters as much as the steel. The test evidence names the exact build that passed. Your job after installation is to keep the doorset matching that build, and to prove it with records. Everything in this guide follows from that one idea, and the same thinking appears in our guides on related ratings.
The rating also stays with the doorset, not the building. If a rated door is removed and refitted elsewhere, the reinstallation must follow the manufacturer’s method and the new wall must suit the rating, or the evidence no longer describes the installation. Relocation is a new installation in the eyes of the rating, and it needs the same care as the first fit. Our security doors are supplied with the installation detail the rating assumes.
Changes that void the rating
Some changes obviously break the rating. Fitting a different lock, drilling new holes for cables or signage, swapping the glazing for a different make-up, or cutting the leaf down all change the tested assembly. The rating cannot survive changes the test never saw, because the test is the only proof the rating has.
Wall alterations count too. The test assumes the surrounding structure resists attack at least as well as the doorset. If a refurbishment replaces a masonry wall with a lightweight partition beside the door, the weak point moves and the rating becomes meaningless. Any building work near a rated doorset should be checked against the original specification first. On busy estates such as schools, minor works happen often, so the facilities team needs to know which doors are rated; our education sector page shows where these doorsets usually sit.
Electronic hardware deserves the same caution. Adding a maglock, a strike or a cable route means drilling, new fixings and new loads on the leaf and frame. Access control should be part of the original specification wherever possible. Retrofitting it to a rated doorset needs the installer’s written approval before anyone picks up a drill. If the work is planned, involve the installation team early so the method can be agreed in writing.
Even small additions need care: door closers, viewers, kick plates and signage fixed with screws all pierce or load the leaf. If the tested build did not include them, ask the installer before fitting them. The safe rule is simple: if it was not in the tested assembly, do not add it without written advice.
A simple inspection routine
A short routine catches most problems before they matter. The table below suits a typical commercial doorset, from SR2 doors upward. Adjust the frequency to the site, with busier doors and harsher exposures checked more often. The person doing the checks needs no specialist tools, only the schedule and a way to record what they find.
| Check | What to look for | Frequency |
|---|---|---|
| Operation | Door opens, closes and latches without force | Monthly |
| Locks | All locking points engage fully; cylinders turn smoothly | Monthly |
| Hinges and fixings | No loose screws, no dropped leaf, no play in the frame | Quarterly |
| Seals | Weather and smoke seals intact, seated and uncut | Quarterly |
| Glazing | Beads secure, no cracked panes, no loose gaskets | Quarterly |
| Frame and wall | No cracks, no gaps at the frame edge, fixings tight | Annually |
| Finish | No deep corrosion, coating sound | Annually |
Write each check down with the date and the result. A tick sheet kept on file turns maintenance from a chore into evidence, and evidence is what an insurer or auditor asks for after an incident. Our maintenance service, done by our own team or by our installation partners, follows this routine and returns the records with every visit.
Doors that carry both a fire and a security rating need checks for both. Our fire door inspection checklist covers the fire side of that routine, from seals to closers.
Lubrication, seals and finishes
Locks and hinges need light lubrication to the manufacturer’s instruction. Use the product the maker names, applied sparingly to moving parts. Never use heavy grease that traps grit, and never oil a cylinder that the maker says should run dry. Stiff operation is a warning: find the cause rather than forcing the door, because force masks the fault and wears the mechanism.
Seals do quiet work and fail quietly. Check weather seals for splits and compression set, and check that smoke seals sit correctly in their grooves. Replace damaged seals with the same type the doorset was tested with. A seal from a different supplier may look identical and perform differently under attack or fire.
Repainting rules are strict on rated doorsets. Do not paint over intumescent seals, smoke seals or identification labels. Mask them before painting, and use a coating the manufacturer approves for the substrate. On combined fire and security doorsets, the wrong paint on the wrong seal can affect both ratings. Our fire and security doors carry both performances, so their finishing instructions deserve particular care.
Records to keep
Keep four sets of paper for every rated doorset: the test evidence for the rating, the installation record showing it was fitted to the manufacturer’s method, the maintenance log with dates and findings, and written approval for any change made after installation. Store them where the facilities team can find them, not in one person’s inbox. If the doorset includes rated glazing, record the class and spall marking too; our guide to bullet resistant vs bulletproof glass explains what those markings mean.
Photographs help. A dated photo of each doorset, showing the leaf, frame, locks and labels, gives the next contractor or auditor a baseline to compare against. Store the photos with the log, and retake them after any change, however small. A picture taken today settles arguments about damage tomorrow.
When a door changes hands between contractors or the building changes owner, the records should travel with it. A rating without paperwork is a claim, and claims do not satisfy insurers. A complete file does. The comparison in our LPS 1175 vs EN 1627 guide makes the same point from the specification side: the rating is only as useful as the paper that proves it.
When to call the installer
Call the installer before any change, not after. New access control, a different cylinder, additional signage, building work beside the door: all of these deserve a written answer first. The installer knows the tested build and can say whether a change is harmless, needs a like-for-like part, or needs a fresh look at the specification. A quick question now beats a voided rating later.
Call urgently if the door has been attacked, forced, or hit by a vehicle, even if it still works. Hidden damage to fixings or the frame can leave the rating intact on paper and gone in practice. After any incident, the doorset needs inspection, the log needs an entry, and the insurer needs to know.
Drill nothing without advice. A single new hole for a cable or a sign can void the rating on the whole doorset. Ask the installer first; the answer is usually quick.
What the rating does not cover after handover
The rating covers the doorset as supplied and installed, not as it becomes. It does not cover a wall that is rebuilt around the door, a floor that is raised against the threshold, or a corridor that is re-planned so the door opens the other way. Each of those changes the opening the test described, and the rating does not follow the change.
It does not cover use the test never saw. A doorset tested for occasional use, then put on a corridor that cycles hundreds of times a day, wears its hinges, closer and lock faster than the test assumed. The rating is a test result, not a promise about every use, and heavy use needs a heavier inspection routine.
It does not cover damage. A leaf dented by a trolley, a frame bent by a forklift, a lock forced by a lost key, each takes the doorset outside its tested state until it is repaired with the tested parts. A repair with a different lock case, a different hinge or a different seal is a change to the tested assembly, not a repair.
It does not cover the finish. Powder coating that is chipped and left bare lets corrosion start at the breach, and corrosion at a hinge or a fixing weakens the assembly the test relied on. Touch up chips promptly, and treat the finish as part of the rating, not as decoration. The same applies to glazing: a vision panel that is cracked or loose changes the assembly the test described, so check the bead and the seal around the glass at every visit.
And it does not cover time on its own. A rating has no expiry date, but the doorset ages. Seals harden, fixings loosen, the frame moves with the building. The rating stays valid only while the doorset still matches its test evidence, and the inspection routine is what proves that match.
Evidence to keep for the next inspection
Ask for the evidence before the order is placed, not after the doors arrive. The six items below belong in the handover pack, and the next inspection starts from them.
- The LPS 1175 certificate, naming the standard, the issue, the rating and the exact doorset.
- The hardware schedule, listing every lock, hinge, closer and seal as tested.
- The test report, showing the tool category, the attack time and the construction tested.
- The installation record, showing the fixings, the frame and the wall the door was fitted into.
- The inspection log, with dates, findings and the name of the person who checked the door.
- The repair record, showing every part changed and the evidence that the replacement matches the test.
A door with its evidence in order is a door that can be checked, repaired and kept. For the ratings in full, see the LPS 1175 page, and for writing the specification so these decisions are made once, see the guide to specifying security doors. For planned servicing and records, see our maintenance page, and for the fire door side of the same discipline, see the fire door inspection checklist.
Frequently asked questions
Does replacing a lock cylinder void the rating?
Fitting a different cylinder changes the tested assembly, so it can. Always fit the cylinder the rating was tested with, or get written approval from the installer first. Keep the receipt and the product details in the maintenance file.
How often should a rated door be inspected?
Monthly checks of operation and locks suit most commercial doors, with a fuller quarterly look at hinges, seals and glazing, and an annual check of frame, wall and finish. Busier doors and harsher sites deserve shorter intervals.
Can we repaint the door ourselves?
Yes, if you mask the seals and labels and use an approved coating. Never paint intumescent or smoke seals, and never cover the rating label. If in doubt, ask the installer which products are approved for your doorset.
The wall beside the door is being rebuilt. Does that matter?
It can. The rating assumes the surrounding structure resists attack at least as well as the doorset. Tell the installer before the work starts so the new construction can be checked against the original specification.
What if the door was forced during a break-in?
Treat the rating as suspect until the doorset is inspected. Damage to fixings, frame or leaf may not show on the surface. Log the incident, arrange an inspection, and keep both on file for the insurer.
Do we need a specialist maintenance contract?
Not always, but the work must follow the manufacturer’s schedule and be recorded. For high-risk sites and large estates, a contract with the installer keeps the routine consistent and the records complete.