Office Security Doors
Office security doors for entrances, stair cores and plant rooms: the grade follows the room, fire and forced entry on one leaf and access control.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
An office is a building of many rooms, and each room needs a door that matches what sits behind it. The entrance takes a door that welcomes staff and visitors, the stair core takes a door that holds fire back, and the plant room takes a door that holds its own line.
The grade follows the room, not the floor. A server room on the third floor takes a higher grade than the meeting room beside it, because the server room holds something worth taking, while the meeting room holds only chairs.
The rules for the shared parts of an office are set out in the fire door regulations offices guide, and the types of security doors guide works through the doors that guard each part of a building. A door ordered without the room it must guard may land on the wrong opening, so the leaf and the rating are named beside the room they serve.
- LPS 1175 B3 / C5 / D10Forced entry periods to LPS 1175
- FD30 / FD60Fire periods on one leaf
- Entrance, stair, plantThe doors of one floor
- One scheduleEvery office door on one line
The grade follows the room: what an office door must hold
An office door is proved against the attack the room behind it faces. Forced entry is proved to LPS 1175, with B3 holding three minutes, C5 holding five minutes and D10 holding ten minutes all under Issue 8.2, dated September 2024. The room that holds cash, records or servers takes a higher grade than the room that holds only desks.
The grade on the order follows the risk behind the leaf, not the size of the opening. A ground floor entrance takes a higher grade than a door on the fifth floor, because the ground floor is the floor an intruder reaches first.
A proof names the whole doorset, not one part of it. The leaf, the frame, the fixings and the lock went to the test as one assembly, so a leaf changed after the test leaves the door without the proof it was ordered with. What voids that proof once the door is fitted is covered in the keeping an LPS 1175 rating valid guide.
Entrances, stair cores and plant rooms: the doors of one floor
The entrance takes the door the public sees, and it must hold its line while looking like part of the building. A glazed leaf lets light into the lobby and lets staff see who stands outside, and the glass beside the leaf takes the same grade as the leaf, because the attack moves to the weakest part of the frontage. The fire rated windows guide covers the windows that share the same wall.
The stair core takes a door that holds fire back while letting people out. A stair door takes FD30 or FD60 to EN 1634-1, with the period following the part of the building it guards, and the leaf must shut on its own every time. The fire door regulations commercial buildings guide sets out the periods for the shared parts of a public building, and the closer that pulls the leaf shut is covered in the fire door closers guide.
The plant room takes a door that holds its own line, because the room behind it feeds the whole building. A plant room door takes the period the fire load behind it demands, and the leaf, the frame and the seals were proved together, so a leaf swapped for another after the test carries no proof on the new opening. The plant room door requirements guide covers the doors on the rooms that feed a building. The laboratory security doors guide covers the rooms that hold more than desks, and the warehouse security doors guide covers the doors on the rooms that hold the stock the office sells.
LPS 1175 on an office floor: B3, C5 and D10 by the room
B3 holds three minutes against the tool set for its category, and it suits the rooms an intruder would try first and leave fastest. A meeting room, a store and a corridor door take B3 and the leaf that guards them needs only to hold long enough for the alarm to answer.
C5 holds five minutes, and it suits the rooms that hold something worth taking. A finance office, a records store and a server room take C5, because the rooms behind them hold cash, records or machines, and the leaf that guards them must hold while help comes.
D10 holds ten minutes, and it suits the rooms that must hold longest. A cash office, a strong room and a room that holds the keys to the building take D10, because the rooms behind them hold what the whole office runs on. The security door cost factors guide works through what each step up the scale adds to the price.
One leaf, two proofs: fire and forced entry on an office door
An office door often needs two proofs on one leaf, because the leaf must hold fire back and hold an intruder out at the same time. Fire resistance is measured in E, EW and EI from 30 to 120 minutes under EN 1634-1, and the letters beside the number say what the doorset held back. Forced entry is proved to LPS 1175, with B3, C5 and D10 holding three, five and ten minutes. The leaf, the frame and the seals were proved together for both.
The hardware on a leaf with two proofs must serve both, because the lock that holds an intruder out must also let people out when the alarm sounds. A lock that needs a key to open from inside traps the people behind it, so the leaf takes a release that opens with one action and still holds the leaf shut against attack. The fire door hardware guide covers the lock the key turns.
Glazing on a leaf with two proofs takes a pane that was proved with the leaf, because a pane that holds fire in one frame can fail in another. The glass, the bead, the frame and the fixings travel to the test as one door, and the test report names them all.
Glazing, vision panels and the glass beside the leaf
An office runs on light, and the glass in its doors lets light through while the leaf holds its line. A vision panel in the leaf lets staff see who stands on the other side before the leaf opens, and the panel takes the same period as the leaf, because the attack moves to the weakest part of the door. The acoustic doors guide covers the leaves that keep a meeting room quiet.
The glass beside the leaf takes the same grade as the leaf beside it, because a door proved to LPS 1175 can still be reached through the glass beside it. The pane beside the leaf is the way in when the leaf itself will not move.
The bead that holds the pane must hold it when the furnace runs, and the bead takes the fixing the test report names. A bead that has moved, a seal that has hardened or a gap that has opened is written against the door it belongs to before the visit ends, so the repair is ordered while the fault is still small.
Access control on an office floor: readers, fobs and the key
An office with many doors needs its entry planned, not piled up. One fob can open the doors that belong together. A member of staff opens the main entrance and their own floor, a cleaner opens the rooms they clean and no others, and a manager opens the whole building.
Visitors take a different path from staff. A visitor calls from the panel, the person inside answers, and the release throws for that one visit. The panel that calls the wrong floor opens the wrong conversation, so the panel, the reader and the release are named beside the door they serve.
The key stays in the plan beside the reader, because a fob or a code cannot open a door when the reader has no power. The person who holds the key must still get through when the system is silent, so the cylinder beside the reader takes a key that works on its own. The fail position of each door is settled before the order goes out, because the answer decides what the leaf does in a blackout. A leaf on an escape route opens when the power fails, while a leaf that guards cash or servers stays shut when the power fails.
The office door on the inspection round: what each visit must check
The round that looks after office doors walks every floor in turn and looks at the leaf, the frame, the seals, the closer and the lock on each door. The leaf is watched as it opens and shuts, the closer is checked for the power that pulls the leaf home, and the lock is tried with the key that belongs to it, so a fault is found on the round and not by the first person who cannot get in.
Each fault is written against the door it belongs to on the same day, with the part and the date beside it, so the repair follows the fault and the door never stands open. The record that holds the faults lives with the building file, in one place, and it is kept current.
The closer on an office door must pull the leaf shut every time, because a seal in a groove does nothing while the leaf stands open. The security door maintenance checklist covers the doors that must hold both fire and forced entry, and the office door that guards a floor belongs on the same round.
| Position | Door | Proof | What to check |
|---|---|---|---|
| Main entrance | Glazed leaf | LPS 1175 B3 | Leaf, glass, lock |
| Stair core | Fire leaf | FD60 | Leaf, closer, seals |
| Server room | Steel leaf | LPS 1175 C5 | Leaf, lock, reader |
| Plant room | Steel leaf | FD60 | Leaf, seals, gap |
| Meeting room | Timber leaf | FD30 | Leaf, closer, latch |
One schedule for the whole floor: every office door on one line
Put the office door order together as one list, with a line for every door on the floor and the leaf, the rating, the lock and the reader beside each one, so the door that arrives matches the door that was proved. A schedule that names one leaf for the whole floor leaves the fitter to guess which room takes which rating.
Read each quotation against the schedule line by line before the order goes out, so no leaf, lock or reader is missed from the price. A part missed from the quotation still has to be bought, and fitting it after the door is hung costs more than ordering it with the door. The columns the schedule needs are set out in the how to specify security doors guide, and what each step up the scale adds to the price is covered in the security door cost factors guide.
An office door holds only as long as the room it guards and the proof behind it, so the grade, the lock and the reader must all sit on the same schedule.
What grade should an office door carry?
LPS 1175 B3, C5 or D10 to the room the door guards, with FD30 or FD60 where the leaf must also hold fire back.
Can one leaf hold fire and forced entry?
Yes, where the leaf, the frame and the seals were proved together for both, to EN 1634-1 for fire and LPS 1175 for forced entry.
Do office doors need access control?
Where the floor holds rooms that only some staff should enter, a reader and a fob open the doors that belong together and keep the rest shut.
What happens when the power fails?
A door on an escape route fails safe and opens, so people can leave. A door that guards cash or servers fails secure and stays shut, so the line holds.
Who checks the office doors?
The person who runs the building, on the round that walks every floor. Each fault is written against the door it belongs to on the same day it is found.