Certified physical security

ArxBridge
Fixed, shallow-mount and automatic bollards in a line on a UK street

ArxBridge

How to choose HVM bollards: fixed, shallow mount, removable and automatic

How to choose HVM bollards in the UK: fixed, shallow-mount, removable and automatic types compared, with spacing, foundations, ratings and maintenance covered.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Choose the bollard type by access needs first and the rating second. Fixed bollards suit permanent lines, shallow-mount suits sites where digging is limited, removable suits occasional access and automatic suits controlled entry points. Every type should carry a vehicle impact rating matched to the threat vehicle.

  • Four typesFixed, shallow-mount, removable and automatic
  • Rating basisThreat vehicle, impact speed and penetration
  • Pedestrian gapsWide enough for wheelchairs, too narrow for a car
  • Golden ruleA line is only as strong as its widest gap

The four bollard types and where each fits

HVM bollards fall into four working types. The differences are about foundations and access, not just appearance. Pick the type that fits how the site operates day to day, then set the rating from the threat assessment.

Cost follows the same order as complexity. Fixed units are the most economical to buy and install, shallow-mount adds engineering, removable adds sockets and manual handling, and automatic adds power, controls and servicing. Choose the simplest type that meets the operational need, because every moving part is a future maintenance task.

Type Best for Foundation Access
Fixed Permanent perimeters and building frontages Deep concrete foundation None; always in place
Shallow-mount City centres and retrofits over services Shallow excavation, less digging None; always in place
Removable (lift-out) Occasional emergency or service access Socket cast into the ground Manual lift-out, then locked back
Automatic (rising) Controlled entry points with frequent movements Pit with drainage and power Powered raise and lower

Fixed bollards: the default for permanent lines

Fixed bollards are the simplest answer where a line never needs to open. Each unit is cast into a deep concrete foundation, so the impact load transfers straight into the ground. There are no moving parts to service and nothing for an operator to forget.

Use them for building frontages, pavement edges, pedestrian zones and anywhere the protected line is permanent. Where the streetscape matters, a rated core can sit inside a decorative sleeve, but the rating belongs to the tested assembly, not to the sleeve on its own.

Finishes need the same discipline as the core. Powder coating to a chosen colour is normal, but any sleeve or cladding must be part of the tested assembly or sit clear of the impact load path. A decorative addition that was never tested can become debris in an impact.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Shallow-mount bollards: less digging, real trade-offs

Shallow-mount bollards were developed for sites where deep excavation is difficult: city centres with dense buried services, bridges, decks and retrofits over basements. The foundation needs far less digging than a traditional deep-mount unit, which cuts the risk of striking power, drainage or telecoms and shortens the installation programme.

The trade-off is physics. A shallower foundation gives the ground less to hold on to, so the engineering works harder to earn the same rating. Always check the test evidence names the shallow foundation explicitly, and confirm the ground conditions on your site match the tested interface. Our security bollards page lists the rated options.

Removable and automatic bollards for managed access

Some lines must open. Removable lift-out bollards suit occasional access: emergency vehicle routes, service yards and event spaces. Each bollard lifts out of a ground socket, usually with a lifting frame, and locks back into place afterwards. They need no power, which suits remote sites.

Automatic rising bollards suit entry points with frequent movements: staff car parks, loading bays and secure compounds. They raise and lower on a powered drive, linked to the access control system. Plan for power, drainage in the pit and a maintenance schedule from day one, because a rising bollard is a machine as well as a barrier.

An open bollard is a gap, not protection. A removable unit left out of its socket, or an automatic unit held down for convenience, leaves the line unprotected. Build the operating routine around keeping every unit in place.

Spacing, gaps and the weakest link in a line

Bollards only work as a line. The clear gap between two units must stop the smallest threat vehicle passing through, while staying passable for wheelchairs and pushchairs in line with DDA access expectations. Set the spacing from the threat vehicle width, not from what looks neat on the paving plan.

Walk the whole line and look for the weak points: the gap at the end of a run, the driveway left open for deliveries, the unit removed for works and never replaced. An attacker uses the easiest opening, so the strength of the line is set by its widest gap, not by its strongest bollard.

End treatments matter just as much. A run that stops short of a wall, a planter or a level change leaves a drive-around. Tie both ends of the line into something a vehicle cannot pass.

Spacing rules come from guidance rather than a single law. Our guide to bollard regulations in the UK explains spacing, height and depth with the source of each number.

Matching the rating to the threat vehicle

The rating follows the threat assessment. A 1,500kg car at 48 km/h is a different problem from a 7,500kg truck at 80 km/h, and the rating must name the vehicle, the speed, the angle and the penetration. Our vehicle impact ratings guide explains how to read the full rating string.

Do not overspecify blindly. A higher rating usually means deeper foundations, heavier units and longer lead times. Match the rating to the assessed threat vehicle and approach speed, then spend the remaining effort on closing the gaps in the line.

If the threat picture is still unclear, the hostile vehicle mitigation overview and the PAS 68 vs IWA 14 vs ISO 22343 guide will help you brief a consultant before you commit to hardware.

Foundations, services and maintenance

Foundations decide the programme. Deep-mount units need excavation that can clash with buried services, so order a services survey before fixing positions. Shallow-mount units reduce this risk but still need the ground interface from the test to hold true on site.

Maintenance follows the type. Fixed and shallow-mount bollards need little beyond visual checks and keeping the line complete. Removable units need their sockets kept clear of grit and ice so they seat and lock properly. Automatic units need scheduled servicing of the drive, seals, drainage and controls, plus a tested failure mode so a power cut leaves the site safe.

Sequence the works sensibly. Confirm service locations, pour the foundations, set the units, then complete the surfacing around them. Bollards installed before the final surfacing often end up at the wrong height or buried in build-up, so protect the finished levels in the programme.

For entry points that need gates rather than bollards, see security gates and sliding vehicle gates. Public realm schemes can check the public spaces sector notes, and a related combined-rating topic is covered in fire and security doors dual certification. All guides are listed in the guides hub.

What a bollard choice does not prove

A rating on a bollard proves one thing: the tested barrier stopped the test vehicle within the stated penetration. It proves nothing else. Treat the certificate as a narrow statement, and ask what it leaves out before the order is placed.

It does not prove the line is closed. A bollard stops a vehicle where the bollard stands, and a vehicle that can drive around the end of the line, through a gap wider than 1,200 mm, or over a kerb has not been stopped. ProtectUK guidance sets 1,200 mm as the maximum clear gap between barriers in a line and 500 mm as the minimum height, so check the whole frontage, not one product.

It does not prove the rating suits the threat. The rating names a test vehicle, a speed and an angle, and a vehicle heavier or faster than the test vehicle is outside the rating. Test vehicles run from a 1,500 kg car to a 30,000 kg truck, and test speeds are 48, 64 and 80 km per hour. Start from the threat vehicle and the speed it could reach on the approach, and ask for the test report, not the rating string alone.

It does not prove the foundations. The rating covers the installed system, not the product on its own, and a bollard that passed its test in one foundation detail does not carry the rating in a different one. Shallow-mount bollards suit ground where digging is limited, but the foundation detail still decides whether the rating holds.

It does not prove the access still works. A fixed bollard closes a route for good, and a removable or automatic bollard must open for the vehicles that need to pass and close again behind them.

Mistakes that leave a bollard line open

Most bollard lines fail in small ways. Each mistake below has the same result: a line that looks complete and stops nothing.

Mistake Why it fails What to do instead
Gap at the end of the line wider than 1,200 mm A vehicle passes through the gap beside the last bollard. Close every gap to 1,200 mm or below.
Bollard ordered without the foundation The rating covers the installation, not the product alone. Order bollard, foundation and ground works as one tested installation.
Unrated street furniture in the line A planter or a bench with no rating is a gap with a shape on it. Use only rated elements in the line.
No survey before digging Services at foundation depth stop the work or break the foundation. Map utilities and ground conditions first.
Removable bollards with no key control Anyone with the key can open the line and leave it open. Hold the keys with the site team and log every removal.

Keep the evidence with the line. The test report, the rating and the foundation design should travel with the installation, so the next inspection can check what was fitted against what was tested. For the rating behind the choice, see our PAS 68 bollards guide, and for the foundation detail the rating depends on, see our PAS 68 bollard foundations guide.

Frequently asked questions

Can a rated bollard go into any ground?

No. The rating is tied to the foundation and ground interface used in the test. Check the test evidence and make sure your site conditions match it.

Do shallow-mount bollards give the same protection?

They can carry the same rating, but only where the test evidence covers the shallow foundation. It is the rating that counts, not the mounting style.

How wide should the gap between bollards be?

Narrow enough to stop the smallest threat vehicle, and wide enough for a wheelchair to pass. Set the spacing from the threat vehicle width first, then check the clear gap against access needs. Where the two conflict, the threat assessment decides.

What maintenance do automatic bollards need?

Scheduled servicing of the drive, seals, drainage and controls, plus a proven safe failure mode for power cuts.

Are removable bollards as strong as fixed ones?

A lift-out bollard seated and locked in its socket can carry a rating, but the line only protects while every unit is in place and locked.

Planning a bollard line?Send the site plan and the threat vehicle, and we will return a rated layout within one working day.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.