A car park fills with drivers who do not know the decks, so each fire door takes its period from the room behind the leaf, from stair core to plant room.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A car park is a stack of decks where drivers come and go all day, and the fire doors are the leaves that hold a fire on the deck where it started while the drivers find the stair core. Each leaf takes its period from the room behind it, because a stair core, a cash office and a plant room ask different things of the doors that guard them.
Car parks share their fire rules with other commercial buildings, and those shared rules are set out in the fire door regulations commercial buildings guide. The stores beside the decks are covered in the warehouse security doors guide, and a car park order names every opening with its period and its hardware beside it, so the leaf that arrives is the leaf the room asked for.
No leaf is ordered before the fire plan is written, and the plan gives every opening its period and every driver the stair core they must reach, so the order follows the plan leaf by leaf.
- FD30 / FD60Fire periods to EN 1634-1
- E / EW / EI 30-120What the letters beside the period mean
- Sa / S200Smoke proof to BS EN 1634-3
- One listEvery deck door named
Decks, cores and rooms: one car park, two periods
A car park works as three parts: the decks where the drivers park, the cores that join the decks, and the rooms behind them where the takings, the systems and the plant sit. The rules follow those parts, because a leaf between a deck and a stair core must hold the fire on the side where it started while the drivers on the far side reach the way down.
The cores take the doors that let drivers pass from deck to deck, and each leaf must open for a driver who has never seen the building before. The rooms take the doors that guard the takings and the plant, and each leaf must hold the fire back where the money and the machinery sit.
The plan gives every opening a door of its own, so a leaf ordered for the plant room never ends up guarding a stair core, and a leaf ordered for the cash office never ends up on the route.
FD60 on the cores, FD30 on the route: the periods each deck takes
Each part of a car park asks a different period of its doors, because the load behind each leaf differs. The stair cores hold the way out, the plant rooms hold the machinery that serves the whole stack, and the cash offices hold the takings, so the period on each door follows the room and never the leaf alone.
The minutes on a leaf come from a test to EN 1634-1, where flames and heat meet the leaf and the clock runs. Beside the minutes sit letters, and the letters say what the leaf held back: flames alone, flames with some of the heat, or flames with the heat as well.
The heavier the proof, the deeper the frame and the stronger the hinges, so a 60-minute leaf costs the order more than a 30-minute one. Where the opening asks for 60 minutes, a 30-minute leaf is the wrong leaf, because the wall fails at its weakest proof.
The stair core: the way up, the way down and the doors between
The stair core runs through every deck in the car park, and the doors on it must hold their proof while letting drivers pass up and down all day. A glazed leaf lets a driver see the core beyond it without opening the leaf, and the pane takes the same proof as the leaf, because the leaf and the glass are proved as one doorset.
The cars and the fuel on the decks carry a fire load of their own, and the doors between a deck and the core must hold the fire where it starts. The core side of that wall takes the period the core demands, because the fire that starts among the cars must stay among the cars while the drivers move down.
What the pane must hold is named in the fire rated windows guide, and the fire rated glass cost guide works through what the glass itself adds to the order.
Cash offices and stores: the rooms behind the decks
The cash office takes the heaviest care in the car park, because the takings sit behind its leaf all day. A cash office leaf takes FD60, and the period follows the value in the room, not the size of the building.
The stores beside the decks take the same care, because the spares and the stock sit behind their doors. A stores leaf takes FD60 where the stores sit beside the plant room, because the fire that starts among the stock must not reach the machinery.
A leaf on a cash office or a stores room often needs two proofs at once, because the rooms behind it need fire held back and an intruder held out. The fire side follows EN 1634-1, with E, EW and EI from 30 to 120 minutes, and the forced entry side follows LPS 1175, with B3, C5 and D10, and both tests run on the same leaf, frame and seals, so one report holds both proofs. The LPS 1175 vs PAS 24 guide puts the two ratings side by side, and the fire and security doors dual certification guide shows how one doorset carries the pair.
Plant rooms, offices and the machinery that keeps the decks running
The plant room takes the same care as the cash office, because the machinery and the boards sit behind its doors all day, so its leaf takes FD60.
The office holds the records and the bookings, and the leaf that guards it takes the period the room beside it takes. An office leaf takes FD60 where the office sits beside the plant room, because the fire that starts among the machinery must not reach the records.
Leaves that must stand open through the working day take a hold-open device proved to BS EN 1155, which lets the leaf go the moment the alarm sounds. A wedge under a leaf is not a hold-open device, because the leaf it holds open cannot shut when the fire reaches it.
Down the core: the way out when the alarm sounds
When the alarm sounds in a car park, the drivers head for the stair core the signs name, and the core must be clear of anything left against its doors. The leaves on that way open at a single push from the first driver to reach them, and they open the same way when the power has gone.
Each route door carries a smoke rating beside its fire period, and BS EN 1634-3 gives it: Sa where the smoke is at room temperature, S200 where it is at 200 degrees. Smoke gets to the route before the flames do, so the seal must meet the frame all the way round, and a gap anywhere lets the smoke past. The smoke control doors guide sets out how the doors hold smoke back while drivers move past them.
The route holds only as long as the leaf on it with the shortest proof, so every leaf on the route takes the period the route needs, and one that is proved for less falls first and takes the route with it. The same care with visitors is taken in the fire door regulations leisure centres guide.
| Position | Door | Period | What to check |
|---|---|---|---|
| Stair core | Steel leaf | FD60 | Leaf, lock, seals |
| Plant room | Fire leaf | FD60 | Leaf, seals, gap |
| Cash office | Steel leaf | FD60 | Leaf, lock, reader |
| Office | Steel leaf | FD60 | Leaf, lock, seals |
| Stores | Steel leaf | FD60 | Leaf, lock, seals |
| Public route | Fire leaf | FD30 | Leaf, bar, closer |
What holds the period on a car park leaf: closers, seals and gaps
The closer on a car park leaf works harder than the closer on most other doors, because drivers pass through it all day with bags and trolleys. BS EN 1154 sets EN 3 as the smallest closer power on a fire door, and the check is simple: open the leaf, let it go, and watch it shut on its own. Where the closer has lost its pull, the leaf stays open after the drivers have passed.
The leaf hangs with a 4 mm gap round it, so it swings free and the seal meets the frame once the leaf shuts. The intumescent seal swells when the heat nears 200 to 250 degrees, and it fills the gap the fire would use, unless paint over the seal holds it back. Where a seal has slipped from its groove, the fault goes in the record against its door on the day it is found.
Each hinge carries its share of the leaf through every opening, and a loose one lets the leaf drop a little at a time until it drags and the gap at the top lets smoke through. The fire door hardware guide sets out what the lock the key turns must do, and closer sizes and fitting are covered in the fire door closers guide.
Ordering the car park doors: one line for every leaf
The whole car park order sits on one list, a line for every door with the leaf, the period, the lock and the closer beside it, so the door that arrives is the door each room asked for. A list that names a single leaf for the whole car park leaves the fitter to guess which room takes which period, and a leaf fitted to the wrong room guards the wrong thing.
Before anything is signed the car park reads the quotation against the schedule, door by door, because a leaf with no figure beside it still arrives with a charge, and a closer ordered after the doorset was sent costs more than the same closer ordered with it. The columns the list must hold are named in the how to specify security doors guide, and what each step up the scale adds to the figure is worked through in the security door cost factors guide.
Each week the car park team tries a few leaves, so every door is tried in turn across the month: the entrance leaves at opening, the core leaves before the first driver arrives, and the cash office leaf at closing. A fault is written against the door it belongs to on the day it is found, with the part and the date beside it, and the repair is booked while the fault is still small. The fire door inspection checklist names what each visit should look for, and the doors that must hold both proofs are covered in the security door maintenance checklist.
On a car park the period, the release and the closer decide together whether the cores, the cash office and the plant room hold, so all three sit on the same list before the order goes out.
What period should a car park door carry?
The minutes on a car park leaf come from EN 1634-1, and they change with the room. A stair core leaf holds fire for sixty minutes while the public route leaf holds it for thirty, so the order names the period room by room.
Can one leaf hold fire and forced entry?
Yes, when one doorset faces both tests on the same leaf, frame and seals, the pair is proved together and one report holds them both.
Do car park doors need panic hardware?
Yes, the leaves on the way out take panic bars proved to BS EN 1125, across at least 60 percent of each leaf, so one push throws the latch for a driver who has never used that door before.
What period should a stair core door carry?
A stair core leaf takes FD60, because the core is the way out for every deck, and the doors on it must hold while the drivers move down.
Who checks the car park doors?