An MRI room is a Faraday cage: a continuous conductive enclosure that blocks outside radio signals from reaching the scanner and keeps the scanner’s own signals contained. Specify the attenuation in dB across a stated frequency range, treat every door, window and cable route as a weak point, and test the finished room before the scanner is installed.
- Faraday cageA continuous conductive shell around the scan room
- AttenuationCommonly specified around 90 to 100 dB
- Weak pointsDoors, windows, filters and waveguides
- AcceptanceTested after installation, before handover
The Faraday cage principle
A Faraday cage works by surrounding a space with a conductive material, usually copper or aluminium sheet, so that electromagnetic fields induce currents in the shell rather than passing through it. For an MRI suite the cage lines the walls, floor and ceiling of the scan room, and every panel is joined to the next with a continuous electrical bond. One gap is enough to let radio frequency energy through, which is why the quality of the joints and seals matters more than the choice of metal.
The panels themselves are rarely the limit. At the frequencies an MRI scanner uses, the metal is hundreds of skin depths thick, so the material alone would give far more attenuation than any practical specification asks for. The enclosure only performs as well as its weakest joint, its door, its window and the points where services pass through. A room built with care reaches the specified attenuation; a room with one poorly bonded seam does not.
Cages can be fitted into new buildings and into existing rooms. In a new build the shielding usually goes in during the fit out, coordinated with the structural floor, the services and the scanner delivery route. In an existing department the cage is built inside the current room, which reduces the finished dimensions, so the room size must allow for the lining, the door swing and the scanner’s own footprint. Early coordination with the scanner supplier avoids a cage that the magnet cannot fit through. Our MRI shielded rooms page describes how these enclosures are built.
Attenuation in dB across a frequency range
Attenuation is stated in decibels, and the number means nothing without the frequency range beside it. A common vendor specification for a clinical MRI room is around 90 to 100 dB between roughly 10 and 130 MHz, which covers the operating bands of 1.5 tesla and 3 tesla scanners. The 1.5T system works near 64 MHz and the 3T system near 128 MHz, so the specified range must include the scanner’s own frequency with margin on both sides.
Higher is not automatically better. Above the specified attenuation the scanner sees no practical benefit, because the remaining noise sits below the thermal noise floor of the receiver. What matters is that the specified figure is met at every frequency in the range, not that one frequency measures higher than asked. Ask for a flat performance across the band rather than a peak number at a single point.
The specification should also state how the figure is measured: the test method, the antenna positions and the number of test points around the room. A single measurement at the centre of the room tells you little about the door seals or the filter panel. A proper acceptance test measures across the enclosure, including the penetrations, and records the results against the specification. The table below shows what a complete specification states.
| Item | State in the specification | Why it matters |
|---|---|---|
| Attenuation | The dB figure with the frequency range, for example around 100 dB from 10 to 130 MHz | A dB number on its own is meaningless |
| Test method | The method, antenna positions and number of test points | Proves the figure where leaks are most likely |
| Door | Type, size, gasket system and clear opening for magnet delivery | The largest penetration and the delivery route in one |
| Penetrations | Every cable, pipe, gas and data route with its shielding method | Nothing may cross the shield untreated |
RF shielding and magnetic shielding are different jobs
Radio frequency shielding and magnetic shielding solve different problems with different materials. Copper and aluminium, both non-magnetic, are excellent for RF because their high conductivity reflects and absorbs the electric field component. They do almost nothing for the static magnetic field of the scanner, which passes through them as if they were not there. Our RF shielding page covers the RF side in more detail.
The static field is managed with steel, which has high magnetic permeability and gives the flux a preferred path. Steel shielding is used where the 5 gauss line must be pulled back from a public corridor, a lift shaft or an adjacent room with sensitive equipment. It is a separate layer of design from the RF cage and it is calculated from the magnet’s own fringe field data, not from the RF specification.
Do not assume one material does both jobs. An RF cage of copper gives the room its clean radio environment; steel panels or shunts around the magnet room manage where the static field reaches. The scanner supplier provides the fringe field plots, and the shielding design follows from those plots and the building layout.
Penetration points: doors, windows, filters and waveguides
Every opening in the cage is a potential leak, and the door is usually the largest. A shielded door closes against conductive gaskets, often beryllium copper fingerstock, that maintain contact around the full perimeter when the door is shut. The fingers compress with each closing, so they wear, and the door needs regular inspection to keep its performance. A heavy door that is left ajar gives no shielding at all.
Windows use a conductive mesh laminated between glass panes, which keeps the view into the scan room while maintaining the electrical continuity of the wall. Ventilation passes through honeycomb waveguides: the small cells let air through but are dimensioned below cutoff for the frequencies of interest, so radio energy cannot follow the air path. Power and signal cables pass through filtered penetrations that attenuate conducted noise on the line.
Pipes, medical gases and data links each need their own treatment. A waveguide below cutoff can carry a pipe through the shield; fibre optic data links are ideal because the glass fibre carries no conducted RF at all. The rule is simple: nothing crosses the shield untreated. Every penetration is listed on the drawings, and each one is assigned a shielding method before installation starts. Rooms with wider electromagnetic requirements are covered on our EMP shielding page.
Testing and acceptance
The cage is tested after installation is complete and before the scanner is delivered. Testing too early risks damage from following trades; testing after the scanner arrives makes remedial work far harder. The acceptance test measures attenuation at multiple points, including doors, windows and the filter panel, and the results are compared with the specification.
Leaks are found and fixed, then the affected points are re-tested. Common findings are door gaskets that need adjustment, a filter with a poor bond to the panel, or a waveguide cut to the wrong length. None of these are unusual; the point of the test is to catch them while access is easy. Our installation service, done by our own team or by our installation partners, programmes testing before handover, never after.
Keep the test report with the building records. It is the baseline for every future check, and it proves what the room achieved on the day it was handed over. If image artefacts appear later, the first question is whether the cage still performs as it did at acceptance. For the ratings on the doors elsewhere in the department, our standards guides explain how to read them.
Planning the room with the scanner supplier
The scanner supplier sets the performance the room must meet. Their site planning guide states the required attenuation, the frequency range, the door type and size, and the services the scanner needs. Start from that document and design the cage around it, not the other way round.
Agree the responsibilities early. The supplier typically defines the RF performance and the magnet’s fringe field; the shielding contractor designs and builds the cage to meet it; the main contractor provides the structure, the builders’ work openings and the services routes. The door size deserves special attention: the magnet is delivered in one piece and the shielded door must pass it, so check the delivery path before the cage is built.
Programme the work so the cage is complete, tested and accepted before the scanner delivery date. Scanner installations run to tight schedules and a late cage delays the whole project. A realistic programme leaves time for testing, remedial work and re-testing. Many of these projects sit within healthcare estates, where access constraints shape the programme.
Quench pipe, services and maintenance
The quench pipe carries helium safely out of the building if the magnet quenches. It is a large bore pipe that must cross the shield, and it does so through a waveguide section sized below cutoff, with a straight run that avoids sharp bends. The route is agreed with the scanner supplier because the pipe has strict limits on length and bends, and it must discharge where the vented gas cannot re-enter the building.
Maintenance of the cage is mostly about the moving parts. Door gaskets and fingerstock wear with use and need periodic inspection and replacement; hinges and closers need adjustment so the door seats fully every time. Fixed panels need little attention unless the room is altered. Any alteration, a new cable route, a relocated socket, a different door, must be treated as a new penetration and detailed accordingly.
Re-test the room after any change and at sensible intervals. A short periodic check of the door and the known weak points catches wear before it shows up as image artefacts, and the maintenance log sits alongside the acceptance report as the room’s history. For related reading, see our guides to security shutters vs retractable grilles, safe room and panic room doors and all guides.
One untreated cable ruins the cage. A single new cable pulled through the shield without a filtered penetration can undo the whole installation. Route every addition through the shielding contractor.
Frequently asked questions
What attenuation should an MRI room achieve?
Follow the scanner supplier’s site planning guide. Suppliers commonly specify around 90 to 100 dB across the operating band of the scanner, for example from roughly 10 to 130 MHz for 1.5T and 3T systems. State the figure with its frequency range and the test method in the tender.
Can a shielded room be added to an existing department?
Yes. The cage is built inside the existing room, which reduces the finished dimensions. Check that the remaining space still fits the scanner, the door swing and the delivery route before committing to the design.
Why does the door matter more than the wall panels?
The panels are hundreds of skin depths thick, so the material is never the limit. The door is the largest opening, it moves, and its gaskets wear, which makes it the most likely leak path and the part that needs the most attention.
Who tests the finished room?
The shielding contractor tests the completed cage before the scanner is delivered, measuring attenuation at multiple points including the penetrations. The test report is handed over with the room and kept as the baseline for future checks.
How often should the room be re-tested?