ArxBridge
Fire Door Regulations for Hockey Clubs
A hockey club keeps a pitch beside a clubhouse, a bar and changing rooms, so each leaf takes the fire period its room needs, FD30 in front and FD60 behind.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
At a hockey club the entrance, the clubhouse, the changing rooms and the bar each carry an FD30 leaf, while the kitchen, the back office and the plant room each carry an FD60 leaf. Thirty minutes of hold stand behind the front leaves and sixty behind the back leaves, and the heat and the papers behind them decide which hold each one gets.
EN 1634-1 tests a doorset against fire and gives it a period in minutes, from FD30 up to FD120. The letter that follows the number names what the leaf held back: E where flame alone was held back, EW where flame and part of the heat were held back, and EI where flame and heat together were held back. A leaf marked FD30 holds flame back for 30 minutes, and a leaf marked FD60 holds it back for 60 minutes.
A hockey club runs its day on the pitch outside and its evening in the clubhouse, which sets it apart from a cricket club where the day runs on the square beside a pavilion and the kit store holds bats and pads. The hockey pitch carries a surface made for sticks and a low running ball, so the club is not a football club either, and the play runs on a pitch rather than courts, so it is not a tennis club. The lane venue is covered in the fire door regulations for bowling alleys guide, the called session in the fire door regulations for bingo halls guide, and the pitch venue in the fire door regulations for stadiums guide.
- FD30 in frontThirty minutes on the pitch side leaves
- FD60 behindSixty minutes on the kitchen, office and plant leaves
- PitchThe surface the clubhouse doors face
- One listEvery club leaf named
Seven rooms at a hockey club: the period on each leaf
Seven rooms sit behind the leaves of a hockey club, and the period on each leaf follows what its room holds. Those rooms are the entrance, the clubhouse, the changing rooms, the bar, the kitchen, the back office and the plant room.
The entrance, the clubhouse, the changing rooms and the bar take FD30, because players and visitors move through all four from the first push back to the last whistle. The kitchen, the back office and the plant room take FD60, because the heat, the papers and the plant behind those leaves call for sixty minutes instead of thirty.
| Room | Period | Grade | What to check |
|---|---|---|---|
| Entrance | FD30 | B3 | Leaf, closer, seals |
| Clubhouse | FD30 | B3 | Leaf, closer, vision panel |
| Changing rooms | FD30 | B3 | Leaf, closer, seals |
| Bar | FD30 | B3 | Leaf, closer, gaps |
| Kitchen | FD60 | C5 | Leaf, closer, seals |
| Back office | FD60 | C5 | Leaf, closer, gaps |
| Plant room | FD60 | C5 | Leaf, closer, seals |
Where the club wants a leaf that also resists forced entry, the fire period and the grade are proved on one doorset, so a single report holds both proofs and the order names both together. The fire and security doors dual certification guide covers how the two proofs sit on one leaf.
What FD30 and FD60 hold back at a hockey club
FD30 holds flame back for 30 minutes and FD60 holds it back for 60, and the letter after the number says whether the heat was held back with the flame. E marks a leaf that held back the flame alone, EW marks a leaf that held back the flame with part of the heat, and EI marks a leaf that held back the flame with the heat as well.
A fire that starts hot and grows fast calls for the longer period, and a room that opens onto the way out calls for the shorter one. For that reason the kitchen, the back office and the plant room take FD60, while the entrance, the clubhouse, the changing rooms and the bar take FD30. What proof a leaf must carry before the club accepts it is named in the fire door certification guide.
Where the sixty minutes sit: kitchen, back office and plant room
Teas and hot food come out of the kitchen between matches, so FD60 sits on its leaf and the leaf stays shut while the cookers are hot, because a fire at a cooker grows fast and the clubhouse beside it holds players.
Membership lists, fixture lists and the papers that run the club sit in the back office, so FD60 sits on its leaf as well, and the leaf stays shut while the room stands empty, because the papers behind it would feed a fire and the club would lose the records it runs on. Once the bar shuts, the till is counted in the back office too, behind the same FD60 leaf.
Behind the plant room leaf sit the boards and the pumps that keep the water hot and the floodlights on, so its leaf takes FD60. What a leaf on that room must do is covered in full in the plant room fire doors guide, and the leaf stays shut because the boards behind it feed the whole club.
Entrance and clubhouse: FD30 where players arrive for the match and the evening
Players arrive at the entrance with sticks in hand and kit bags over their shoulders, and spectators follow them in for a drink in the clubhouse before the match, so the entrance leaf takes FD30 and stands on the way out as well as in. The leaf opens to players and their guests while the session runs, and it must open freely when the clubhouse empties.
BS 8300 with Approved Document M caps the push on the entrance leaf at below 30 N through the first 30 degrees of swing and below 22.5 N past that point, so a player carrying a stick and a bag still gets the leaf open. When the alarm sounds while visitors new to the clubhouse are still in the bar, the route to the car park carries a sign at every turn and nothing stands on it. The fire door signage guide names the signs that mark the route at every turn.
The bar takes the takings of the day behind an FD30 leaf that stays shut once the last drink is served, and the cash is carried through to the back office for counting. A venue that counts cash through the night is covered by the fire door regulations for casinos guide.
Changing rooms and bar: FD30 beside the pitch
The changing rooms take FD30, because players leave sticks, phones and wallets on the benches while the match runs on the pitch, and the leaf stays shut while the rooms are empty.
A small vision panel in the clubhouse leaf lets a player see whether the bar is busy before opening the leaf. What a pane in a fire leaf must hold is covered in the fire door vision panels guide.
A way out that serves more than 60 people needs its leaves to carry a push bar proved to BS EN 1125, and the bar must run across no less than 60 percent of the leaf width. One push from a player with a crowd behind them throws the leaf open, and the bar works whether the supply is on or off. What the bar must do under a crowd is covered in the panic hardware guide, and the emergency exit doors guide covers the leaves on the way out.
After the final whistle the players gather at the bar with the pitch in view through the clubhouse windows, and the leaf takes FD30 and shuts while the bar stands empty.
Smoke at the clubhouse: Sa and S200 beside the period
Smoke gets to the clubhouse before flame does, so every leaf needs a smoke seal beside its period, proved to BS EN 1634-3. Sa marks a leaf proved against smoke at room temperature, and S200 marks a leaf proved against smoke at 200 degrees, so the mark on the order names the smoke each leaf was proved against.
The corridor from the clubhouse to the entrance would carry the smoke of a fire in the kitchen or the plant room, so its leaves take smoke seals beside their period. Where a smoke seal sits beside a fire period is covered in the smoke control doors guide.
Closers, seals and gaps: what the hockey club period rests on
The closer that draws the leaf shut after each player carries a proof to BS EN 1154, where EN 1 is the lowest power size the standard lists and no fire leaf takes a power size below EN 3. A closer too weak for the leaf leaves it ajar, and a leaf left ajar holds no period. The fire door closers guide names the power sizes a fire leaf may take.
The intumescent seal round the leaf swells as the heat reaches it, and the swell closes the gap round the leaf edge. The seal starts to expand at around 200 to 250 degrees, and how the seal is fitted and what it must hold is covered in the intumescent seals guide.
The gap round a fire leaf measures 4 mm, taken round the leaf edge and the head rather than guessed by eye. Where the gap is measured and what a wide gap costs the leaf is covered in the fire door gaps guide.
The club leaves hang on hinges proved to BS EN 1935, where grade 13 stands 200,000 cycles with a leaf of 120 kg and grade 14 stands the same cycles with a leaf of 160 kg. What each piece on a fire leaf must carry is covered in the fire door hardware guide.
The hockey club fire door order: every leaf, its period and its proof
One list holds the whole order, and every opening gets a line of its own that names the leaf, the period, the seals and the closer beside it. Without its own line, a leaf may end up hung on the wrong opening, and an FD60 leaf on the changing rooms would hold for 60 minutes where 30 would do.
Once a month the club secretary walks the door list round the club and tries each leaf in turn, looking at the closer, the seals and the gap on each leaf as it is tried. A leaf that will not shut, a seal that is torn and a gap that has grown are written on the list, and the fire door inspection checklist names what the walk round the club should cover.
The larger sports hall beside the club takes its fire rules from the fire door regulations for leisure centres guide, and the fire compartmentation guide names how the rooms of the club are held apart from each other. The fire door maintenance guide names what keeps a leaf holding its period once the order is in.
Before the order is signed, each leaf on the list is read through once more, and the proof for every leaf is checked against the list before the order leaves the club.
The period on a hockey club leaf follows the room behind it, so the leaf, the closer and the seals are ordered together and checked together against the pitch and the takings behind the leaf.
What period does a hockey club entrance take?
FD30 to EN 1634-1, which holds flame back for 30 minutes, because the entrance stands on the way out from the pitch to the car park.
What period does the hockey kitchen take?
FD60 to EN 1634-1, which holds flame back for 60 minutes, because a fire at the cookers grows fast beside a full clubhouse.
What period does the hockey plant room take?
FD60 to EN 1634-1, which holds flame back for 60 minutes, because the boards behind the leaf feed the floodlights and the hot water of the whole club.
What gap does a hockey club fire leaf need?
A gap of 4 mm round the leaf edge and the head, because a wider gap lets flame and smoke slip past the leaf before the period runs out.
Who checks the hockey club fire doors?
The club secretary walks the door list round the club once a month and tries the fire leaves in turn, looking at the closer, the seals and the gap.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.