Cleanroom doors: sealed doors for pharmaceutical and research rooms, with flush surfaces, interlocking doors, fire proof and one schedule for every room.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A cleanroom door holds the room clean and keeps the work inside safe. It seals the opening against dust and draughts, it opens for staff in gowns all day, and it must hold fire back on the escape route, all on the same leaf in many rooms. The door that fails on one of those jobs leaves the room open to contamination, to fire, or to a batch the customer will not accept.
The order starts with the room, not with the door. A pharmaceutical room that fills vials asks for a different door from a research room that tests samples, and a room that must stay shut to the corridor asks for different seals from one that opens to a gowning area. The work, the people and the air the room must hold decide the door before the leaf is chosen.
The doors in a cleanroom sit inside one schedule, and an order that names each one plainly gets the right door on the right opening. The commercial buildings fire door regulations guide sets out the periods for the shared parts of a building, and the data centre physical security by zone guide sets out doors zone by zone in a building that must stay controlled.
- FD30 / FD60Fire resistance periods tested to EN 1634-1
- LPS 1175 B3 / C5 / D10Forced entry ratings, three, five and ten minutes
- 4 mmMaximum gap round a fire door leaf
- TS 007 3-starCylinder and handle sets
The rooms a cleanroom door guards: pharma, research and the spaces between
A pharmaceutical room fills, packs or tests medicines, and the door on it opens many times a day. Every opening lets air through, so the door must shut fast and seal tight, and the closer must pull the leaf shut against the pressure from the corridor, because a door left open is a room that loses the air it must hold.
A research room holds samples, instruments and people who must not be disturbed, and the door on it faces a different job. The leaf must keep the room quiet and the air steady, so the seals round the leaf matter as much as the lock, and the gap round a fire door leaf must stay at 4 mm, because a wider gap lets fire and smoke past whatever the rating on the leaf says.
The university security doors guide covers the doors on an estate where laboratories sit beside teaching rooms, and the server room doors guide covers the doors on the rooms that hold the machines.
Sealing and air tightness: the door that holds the room clean
The seal round a cleanroom door must stay soft through the working day, because a seal that goes hard leaves a gap round the leaf. Air through that gap carries dust into the room, so the seal material belongs on the order beside the room, and the seal must be checked on the inspection round, because a seal that has come away leaves the gap open.
The threshold must let trolleys and staff in gowns pass without a trip, and it must stay clear of dirt. A threshold that holds dirt carries it into the room on every wheel, so the floor in front of the door must be kept clear, and the parts that wear first are covered in our fire door hardware guide.
The frame must carry the same sealing as the leaf, because a leaf that seals tight in a frame that lets air through has failed half its job. The frame, the fixings and the seals belong on the same line as the leaf, so the door that arrives is the door that was proved.
Positive or negative pressure: what the air asks of the closer
A cleanroom holds its air at a pressure above or below the corridor, and the pressure decides what the closer must do. A positive pressure room pushes air out when the door opens, so the closer must pull the leaf shut against the air pushing it open, and a closer too weak for the pressure leaves the leaf ajar and the room losing the air it must hold. A negative pressure room pulls air in, so the leaf must shut against the inward pull, and the same weak closer leaves the same gap.
Closers are sized to BS EN 1154, with power sizes from EN 1 to EN 7, and no fire door takes less than EN 3. The size follows the weight of the leaf and the pressure behind it, so the closer belongs on the order beside the room pressure, not beside the leaf alone. A closer sized for the leaf in still air and fitted to a door in a pressurised room will not shut the leaf, and the gap it leaves is a gap the room cannot afford.
Test the closer with the air handling running, not with it off, because the pressure the room holds in use is the pressure the closer must beat every time the door opens. The fire door closers guide runs through the sizes and the fitting of closers, and the server room doors guide covers the doors on the rooms that hold the machines behind the cleanroom wall. The security door maintenance checklist lists the checks that keep the closers working through the life of the door.
The cleaning regime chooses the finish, not the catalogue
A cleanroom leaf is cleaned every day, and the finish must take the cleaning the room uses. Powder-coated steel suits a room cleaned with mild agents, because the coating holds while the leaf is wiped down, and the coating must be checked for chips, because a chip leaves bare steel that cannot be cleaned. Stainless steel suits a room washed down often or cleaned with stronger agents, because the steel takes the wash without a coating to peel.
Ask the cleaning team which agents they use before the finish is chosen, because a finish ordered without the cleaning regime in mind peels within months, and a leaf that peels cannot be wiped clean. The agents, the cloths and the frequency of the clean all belong on the order beside the finish, so the leaf that arrives is the leaf the cleaning team can keep clean. The how to specify security doors guide names the columns a schedule should carry.
The vision panel must take the same cleaning as the leaf, with the glass sitting flat with the leaf on both faces, so no edge stands out to catch dust. The fire door hardware guide runs through the hinges and handles that must sit flush with the leaf, and the university security doors guide covers the doors on an estate where laboratories sit beside teaching rooms. Send the room plan and the cleaning each room must take, and we will quote a tested leaf for the cleanroom within one working day.
| Finish | Cleaning it takes | Room it suits |
|---|---|---|
| Powder-coated steel | Mild agents, daily wipe | Pharma packing, research rooms |
| Stainless steel | Stronger agents, wash down | Rooms washed down often |
| Coated, checked | Mild agents, chip check | Rooms where coating must stay whole |
Flush surfaces: the leaf that leaves nothing to catch
A cleanroom leaf must be flush, because a bead, a step or a raised panel catches dust and holds it. The leaf, the vision panel and the hardware should all sit flat with the face of the door, so the room can be wiped down without a ledge left dirty, and the glass should sit flat with the leaf on both faces, so no edge stands out on either side.
Handles, locks and hinges must sit flush with the leaf. A lever handle that sticks out, a lock with a thumb turn that stands proud, or a hinge with an exposed knuckle each gives a grip for dust, so the hardware should sit flush, and the hinges should run the full height of the door or hide inside the frame.
Cleaning decides how long a cleanroom door stays clean, because a seal that has come away, a hinge that has worked loose or a handle that has been forced each opens a gap that was not there on the day the door arrived. The inspection round should look for the gap that has grown, and each fault goes on the record the day it is found.
Interlocking doors: the pair that never opens together
An airlock takes two doors, and the pair must never open together. One door opens, the person passes, and the first door shuts before the second opens, so the room behind stays clean while the person moves through, and the interlock belongs on the order beside the doors, not after them.
The interlock must work on power failure as well as on alarm, and it must sit where a person can reach it without hunting for it. A release that needs power to work is no release at all, so the release is checked on the inspection round, and the checks each round should make are set out in our security door maintenance checklist.
The pair must still open for escape. No key, no card and no code may stand between the person and the street, and the release must work for everyone in the building, including a visitor who has never seen the door before. The door on the escape route must release at once when the alarm sounds.
One door opens only after the other has shut
A cleanroom airlock works on one rule: one door opens only after the other has shut. Staff step in from the corridor, the first door shuts behind them, and only then does the second door release. The pause between the two is not wasted time; it is the moment the air settles, and the room beyond keeps the grade it was built to hold.
Test the sequence the way staff use it, not the way the drawings show it. Walk through with a trolley, then with both hands full, and try the second door while the first still stands open. If the second door gives way, the interlock has failed, and the failure is noted on the record that same day, with the room named beside it. The fire door closers guide deals with closer sizes and fitting, and the server room doors guide deals with the rooms holding the machines behind the cleanroom wall.
Where the airlock takes trolleys, the doors must suit the trolley as well as the person. A trolley that wedges the first door open while the second is tried will defeat the interlock without anyone forcing it, so the airlock needs room for the trolley to clear the first door fully before the second is called. For the schedule itself, the how to specify security doors guide lays out what each column should carry.
Gowning, changing and passing through: the airlock sequence at shift change
The airlock is where the grade changes hands. Staff arrive in corridor dress, change into gowning, and pass through to the room beyond, and the doors on each side of the airlock must hold their grade through every change. A door that stands open while gowns are changed lets corridor air straight into the room, and the room spends the rest of the shift recovering what one open door gave away.
Put the gowning bench where it keeps staff clear of both doors. A bench set against the wall between the doors leaves the way through clear, and the doors shut behind each person without being held by a gown, a trolley or a bin. The closers on both doors must pull them shut against the pressure of the room. The closer power sizes in BS EN 1154 run from EN 1 to EN 7, and each size is picked for the weight of the doorset and the pressure it must shut against.
Watch the airlock at shift change, when the most people pass through in the shortest time. If doors are held open for the next person through, the sequence is being worked around, and the answer is a wider airlock or a second one, not a closer set to hold the door open. The fire door hardware guide deals with hinges and handles for a doorset that must sit flush on both faces, and the university security doors guide deals with doors on a university estate, where laboratories sit beside teaching rooms. For the order, send the room plan with the cleaning each room must take, and the enquiry checklist asks for the room plan and the cleaning regime with the order.
| Step through the airlock | Door state | What it protects |
|---|---|---|
| Enter from the corridor | First door opens, second stays shut | Corridor air stays out |
| Wait inside | Both doors shut | Air settles between grades |
| Pass to the room | Second door opens, first stays shut | Room grade holds |
| Return the same way | Sequence runs in reverse | Grade holds both ways |
One leaf, two proofs: fire and forced entry in a cleanroom
A cleanroom door often must do two jobs at once. It must hold fire back for its period, and it must resist a forced entry, and a door that must do both needs a proof for each job. Fire is proved to EN 1634-1 and forced entry to LPS 1175, and the two proofs sit on the same schedule line, because a door proved for one job and not the other leaves the room open on one side.
The period follows the fire load behind the door. Thirty minutes is the period most cleanroom doors carry, and sixty minutes is the period for the doors that guard a compartment wall or a room with a heavier fire load, and a door on a smoke path takes FD30S, with the seal proved to BS EN 1634-3, to Sa for smoke at room temperature and S200 for smoke at 200 degrees Celsius.
How the two proofs sit together is worked through in the fire and security doors dual certification guide. The closer must pull the leaf shut every time, with no fire door taking less than EN 3 to BS EN 1154, and the fire door closers guide covers the sizes and the fitting, while the keeping an LPS 1175 rating valid guide sets out what breaks a rating.
Who opens the cleanroom door: cards, readers and the gowning room
The cleanroom should open for the staff who belong there and stay shut for the rest. A card or a fob opens the door for the staff who use the room every day, and an intercom at the door lets a visitor ask to be let in, so the record shows who opened the door and when.
Run the cleanroom door on the same system as the rest of the site, so one card opens the room, the staff areas and the yard, and one stopped card stops working everywhere at once. Readers, fobs and biometrics in the lane are covered in our security turnstiles guide.
The access control must not trap anyone inside. A door that locks from the outside and will not open from the inside is a danger in a room where staff work in gowns, so the release inside the room works on power failure as well as on alarm, and the release is written into the order beside the reader. The plant room door requirements guide covers the doors on the rooms that feed the building.
Cleaning, wear and the checks that keep a door clean
A cleanroom door is wiped down every day, and the leaf must take that cleaning without the finish coming away. A finish that peels leaves a surface that cannot be cleaned, so the finish belongs on the order beside the leaf, and the parts that wear first are covered in our fire door hardware guide.
Hinges on a cleanroom door must carry the leaf through the daily cycle, and they are proved by cycles and by load. Hinges to BS EN 1935 are proved through 200,000 cycles, with grade 13 carrying 120 kg and grade 14 carrying 160 kg, so the hinge should be chosen for the weight of the leaf it carries.
The closer must pull the leaf shut every time, against the pressure of the room behind it. How the two proofs share one doorset is set out in the fire and security doors dual certification guide.
One schedule for every cleanroom: the order that names each door
Write the enquiry as one schedule with a line for every cleanroom on the site, and put the position, the sealing, the fire period, the forced entry rating, the hardware and the interlock on each line, so the door that arrives is the door that was proved.
Check the quotes line by line against the schedule, because a quote that leaves a seal or a closer off the list is not cheaper, only shorter, and the missing line is paid for later. The security door cost factors guide works through what each step up the scale adds, and the how to specify security doors guide runs through the same discipline column by column.
Keep the test report, the rating and the service schedule with the door from the day it arrives, and write the inspection routine into the handover pack. The columns such a schedule needs are set out in our how to specify security doors guide, and the mistakes to avoid are set out in our security door specification mistakes guide.
| Position | Door | Rating | What to check |
|---|---|---|---|
| Pharma room | Flush sealed door | FD30 | Seals, closer, latch |
| Research room | Flush sealed door | FD30 | Seals, hinges, release |
| Airlock | Interlocked pair | FD30S | Interlock, seals, release |
| Gowning area | Sealed door | LPS 1175 B3 | Frame, fixings, closer |
| Store | Security door | LPS 1175 C5 | Lock, handle, reader |
A cleanroom door holds the room clean and keeps the work inside safe, so the sealing, the flush surfaces and the interlock must all sit on the same schedule.
What makes a cleanroom door different?
The sealing and the flush surfaces. The leaf seals tight against dust and draughts, the vision panel and the hardware sit flat with the leaf, and the door shuts fast every time, so the room keeps the air it must hold.
Can a cleanroom door hold a fire rating?
Yes, where the door has been tested for the job. EN 1634-1 proves the fire side, with FD30 or FD60 naming the period, and LPS 1175 proves the forced entry side, with B3, C5 and D10 naming three, five and ten minutes.
How do interlocking cleanroom doors work?
Two doors in an airlock never open together. One door opens, the person passes, and the first door shuts before the second opens, so the room behind stays clean while the person moves through.
Who opens a cleanroom door?
Staff take a card or a fob for the rooms they use, and the record names who holds each one. A fob can be stopped when staff leave, and the door on the escape route must still release on alarm.
Who checks cleanroom doors?
The person who runs the site, on the routine the site keeps. Each round looks at the seals, the closers, the locks and the interlock, and each fault goes on the record the day it is found.
If this is one of several openings on the site, the enquiry checklist shows the rating, hardware and evidence to name for each.