A powered door, gate or barrier is work equipment. Regulation 18 and PUWER set out who must keep it safe, how it is checked, and what the record shows.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A powered door, gate or barrier is work equipment. Two rule sets decide who keeps it safe: the Workplace Regulations 1992, which ask that every door and gate is built and fitted so no one is hurt, and PUWER, the work equipment regulations, which asks that the equipment is chosen well, kept in order and checked.
- Regulation 18Doors and gates built safe
- PUWERChosen, kept and checked
- EmployerHolds the duties
- RecordChecks written down
What regulation 18 asks of every door and gate
Regulation 18 of the Workplace (Health, Safety and Welfare) Regulations 1992 says doors and gates shall be suitably constructed, including being fitted with any necessary safety devices. The rule covers every door and gate in a workplace, powered or moved by hand.
A sliding door or gate must have a device to prevent it coming off its track, and an upward opening door or gate needs a device to stop it falling back. Both tests are about the leaf or panel itself: a panel that leaves its track or drops back down is a danger to anyone standing under it or beside it.
A powered door or gate must have suitable and effective features to prevent it causing injury by trapping any person. Where necessary, a powered door or gate must be capable of being operated manually, unless it opens automatically if the power fails. The text of regulation 18 sets out each test in full.
The trapping risk a powered door must guard against
Trapping is the risk regulation 18 names for a powered door or gate. A leaf that closes on a person, or a gate that draws a hand into its mechanism, can each injure someone in seconds, and the safety features must stop the leaf or gate before the injury happens.
Three guards are usual: a light beam across the opening, a contact edge along the leaf, and a detector above the opening that sees a person approaching. The beam holds the leaf back while the path is blocked, the contact edge sends the leaf back when it is touched, and the detector keeps the leaf from starting while someone stands in the way. The automatic doors guide gives the sensor detail for a pedestrian opening.
PUWER: suitability before the equipment is chosen
PUWER puts the duties on the employer. Regulation 4 says every employer shall ensure that work equipment is so constructed or adapted as to be suitable for the purpose for which it is used or provided, and that in selecting it the employer shall have regard to the working conditions and the risks in the premises.
Suitability is judged against the job the equipment will do. A gate that cycles dozens of times a day at a loading bay needs a different drive and different safety features from a gate that opens once each morning at a small yard. The HSE PUWER pages set out what the employer must do.
PUWER: maintenance, inspection and the record
Regulation 5 asks the employer to keep work equipment maintained so it stays in a sound state, works as it should, and is in good repair, and where any machinery has a maintenance log, the log is kept up to date. The maintenance follows the maker instructions.
Regulation 6 asks for inspection in two cases. Where the safety of work equipment depends on the installation conditions, it must be inspected after installation and before being put into service for the first time, and after assembly at a new site or in a new location. Where equipment is exposed to conditions that cause deterioration, it must be inspected at suitable intervals and after any exceptional event.
The result of an inspection must be recorded and kept until the next inspection is recorded. No work equipment may leave the employer’s undertaking, or be used in it if obtained from another person, unless it is accompanied by physical evidence that the last inspection required has been carried out. The maintenance checklist guide names the checks a door needs across its life.
Training and the people who use the equipment
Regulation 9 says every employer shall ensure that all persons who use work equipment have received adequate training, including training in the methods which may be adopted when using the equipment, any risks which such use may entail and the precautions to be taken. Employees who supervise or manage the use of work equipment must receive the same training.
Training matters because the safety features only help when the people beside the door know what they do. A driver who holds a barrier arm open for the vehicle behind, or a porter who props a powered gate open with a wedge, can each defeat the safety features in a moment. The automatic gates guide covers the drive and controls on a powered gate.
Who holds the duty on a shared site
A shared site needs the duties written down. Where a landlord provides a powered gate at the entrance to a multi-let building, the HSE overview says a business that provides work equipment for others to use must manage the risks from that equipment. The lease or the management agreement should name who maintains the gate, who keeps the log, and who calls the engineer.
At installation the same question arises: who hands the door over, and with what papers. The commissioning and handover guide has the papers a new door should carry, and the installation handover guide walks the buyer through the checks opening by opening. The replacement guide covers a door swapped while the building stays open. Where the door is a fire door, a failed check can bring a fire safety notice, and the enforcement notices guide names the three notices and the time each one gives.
The checks to ask for before the work is signed off
Ask for the safety features to be proved at the leaf. The leaf should stop on the contact edge, the beam should hold it back while someone stands in the opening, and the manual release should work with the power off.
Ask for the maintenance log and the last inspection record. The log should show the date, the work done, and the name of the person who did it, and the inspection record should show the result and the next date. A powered shutter has its own rules too, and the roller shutter regulations guide gives the machinery and PUWER detail for a powered shutter.
Ask what happens when a safety feature fails. A beam out of line, a contact edge that has gone hard, or a gate that no longer stops on contact should each take the door out of powered use until it is fixed. The fire door maintenance guide has the routine for keeping a fire door in order. A powered door that must shut fast in a lockdown needs the same proof at the leaf, and the NPSA lockdown guide sets out the four lockdown methods and what each door does.
| Duty | What the rule asks | Who holds it |
|---|---|---|
| Regulation 18 | Doors and gates built safe, trapping guarded | Employer |
| PUWER regulation 4 | Equipment suitable for its purpose | Employer |
| PUWER regulation 5 | Maintained, log kept up to date | Employer |
| PUWER regulation 6 | Inspected after fitting and at intervals | Employer |
| PUWER regulation 9 | Users and supervisors trained | Employer |
A powered door is safe only while its safety features work. Prove them at the leaf, keep the log current, and take the door out of powered use when a feature fails.
Does regulation 18 apply to a manual door?
Yes. The regulation reaches every door and gate at work, whether it is powered or pushed by hand. The trapping and manual operation tests apply to powered doors and gates, while the track and falling back tests apply to sliding and upward opening doors and gates.
How often must a powered gate be inspected under PUWER?
PUWER sets no fixed interval in law. Inspection is due after installation and before first use, then at suitable intervals where deterioration could cause danger, and after any exceptional event. The right interval comes from the maker instructions, how often the gate cycles, and the conditions.
Who is responsible for a powered gate on a shared site?
The employer holds the PUWER duties for the equipment their people use, and a business that supplies equipment for others to use must look after the risks that come with it. On a multi-let site the lease should say who services the gate and who holds the inspection records.
Must a powered door open by hand if the power fails?
Where health and safety make it necessary, the door must be openable by hand when the power fails, unless it opens on its own when the power goes out. The manual release should be proved at the leaf before the work is signed off.
What does the inspection record have to show?
The finding, the date, and the date the next inspection falls due. Keep it until the next inspection is recorded, and keep physical evidence with the equipment that the last inspection was carried out.