Certified physical security

ArxBridge
Steel door sample in a security test frame with an assessor in a UK test laboratory

ArxBridge

Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites

A powered door, gate or barrier is work equipment. Regulation 18 and PUWER set out who must keep it safe, how it is checked, and what the record shows.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A powered door, gate or barrier is work equipment. Two rule sets decide who keeps it safe: the Workplace Regulations 1992, which ask that every door and gate is built and fitted so no one is hurt, and PUWER, the work equipment regulations, which asks that the equipment is chosen well, kept in order and checked.

  • Regulation 18Doors and gates built safe
  • PUWERChosen, kept and checked
  • EmployerHolds the duties
  • RecordChecks written down

What regulation 18 asks of every door and gate

Regulation 18 of the Workplace (Health, Safety and Welfare) Regulations 1992 says doors and gates shall be suitably constructed, including being fitted with any necessary safety devices. The rule covers every door and gate in a workplace, powered or moved by hand.

A sliding door or gate must have a device to prevent it coming off its track, and an upward opening door or gate needs a device to stop it falling back. Both tests are about the leaf or panel itself: a panel that leaves its track or drops back down is a danger to anyone standing under it or beside it.

A powered door or gate must have suitable and effective features to prevent it causing injury by trapping any person. Where necessary, a powered door or gate must be capable of being operated manually, unless it opens automatically if the power fails. The text of regulation 18 sets out each test in full.

The trapping risk a powered door must guard against

Trapping is the risk regulation 18 names for a powered door or gate. A leaf that closes on a person, or a gate that draws a hand into its mechanism, can each injure someone in seconds, and the safety features must stop the leaf or gate before the injury happens.

Three guards are usual: a light beam across the opening, a contact edge along the leaf, and a detector above the opening that sees a person approaching. The beam holds the leaf back while the path is blocked, the contact edge sends the leaf back when it is touched, and the detector keeps the leaf from starting while someone stands in the way. The automatic doors guide gives the sensor detail for a pedestrian opening.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

PUWER: suitability before the equipment is chosen

PUWER puts the duties on the employer. Regulation 4 says every employer shall ensure that work equipment is so constructed or adapted as to be suitable for the purpose for which it is used or provided, and that in selecting it the employer shall have regard to the working conditions and the risks in the premises.

Suitability is judged against the job the equipment will do. A gate that cycles dozens of times a day at a loading bay needs a different drive and different safety features from a gate that opens once each morning at a small yard. The HSE PUWER pages set out what the employer must do.

PUWER: maintenance, inspection and the record

Regulation 5 asks the employer to keep work equipment maintained so it stays in a sound state, works as it should, and is in good repair, and where any machinery has a maintenance log, the log is kept up to date. The maintenance follows the maker instructions.

Regulation 6 asks for inspection in two cases. Where the safety of work equipment depends on the installation conditions, it must be inspected after installation and before being put into service for the first time, and after assembly at a new site or in a new location. Where equipment is exposed to conditions that cause deterioration, it must be inspected at suitable intervals and after any exceptional event.

The result of an inspection must be recorded and kept until the next inspection is recorded. No work equipment may leave the employer’s undertaking, or be used in it if obtained from another person, unless it is accompanied by physical evidence that the last inspection required has been carried out. The maintenance checklist guide names the checks a door needs across its life.

Training and the people who use the equipment

Regulation 9 says every employer shall ensure that all persons who use work equipment have received adequate training, including training in the methods which may be adopted when using the equipment, any risks which such use may entail and the precautions to be taken. Employees who supervise or manage the use of work equipment must receive the same training.

Training matters because the safety features only help when the people beside the door know what they do. A driver who holds a barrier arm open for the vehicle behind, or a porter who props a powered gate open with a wedge, can each defeat the safety features in a moment. The automatic gates guide covers the drive and controls on a powered gate.

Who holds the duty on a shared site

A shared site needs the duties written down. Where a landlord provides a powered gate at the entrance to a multi-let building, the HSE overview says a business that provides work equipment for others to use must manage the risks from that equipment. The lease or the management agreement should name who maintains the gate, who keeps the log, and who calls the engineer.

At installation the same question arises: who hands the door over, and with what papers. The commissioning and handover guide has the papers a new door should carry, and the installation handover guide walks the buyer through the checks opening by opening. The replacement guide covers a door swapped while the building stays open. Where the door is a fire door, a failed check can bring a fire safety notice, and the enforcement notices guide names the three notices and the time each one gives.

The checks to ask for before the work is signed off

Ask for the safety features to be proved at the leaf. The leaf should stop on the contact edge, the beam should hold it back while someone stands in the opening, and the manual release should work with the power off.

Ask for the maintenance log and the last inspection record. The log should show the date, the work done, and the name of the person who did it, and the inspection record should show the result and the next date. A powered shutter has its own rules too, and the roller shutter regulations guide gives the machinery and PUWER detail for a powered shutter.

Ask what happens when a safety feature fails. A beam out of line, a contact edge that has gone hard, or a gate that no longer stops on contact should each take the door out of powered use until it is fixed. The fire door maintenance guide has the routine for keeping a fire door in order. A powered door that must shut fast in a lockdown needs the same proof at the leaf, and the NPSA lockdown guide sets out the four lockdown methods and what each door does.

Duty What the rule asks Who holds it
Regulation 18 Doors and gates built safe, trapping guarded Employer
PUWER regulation 4 Equipment suitable for its purpose Employer
PUWER regulation 5 Maintained, log kept up to date Employer
PUWER regulation 6 Inspected after fitting and at intervals Employer
PUWER regulation 9 Users and supervisors trained Employer

A powered door is safe only while its safety features work. Prove them at the leaf, keep the log current, and take the door out of powered use when a feature fails.

Does regulation 18 apply to a manual door?

Yes. The regulation reaches every door and gate at work, whether it is powered or pushed by hand. The trapping and manual operation tests apply to powered doors and gates, while the track and falling back tests apply to sliding and upward opening doors and gates.

How often must a powered gate be inspected under PUWER?

PUWER sets no fixed interval in law. Inspection is due after installation and before first use, then at suitable intervals where deterioration could cause danger, and after any exceptional event. The right interval comes from the maker instructions, how often the gate cycles, and the conditions.

Who is responsible for a powered gate on a shared site?

The employer holds the PUWER duties for the equipment their people use, and a business that supplies equipment for others to use must look after the risks that come with it. On a multi-let site the lease should say who services the gate and who holds the inspection records.

Must a powered door open by hand if the power fails?

Where health and safety make it necessary, the door must be openable by hand when the power fails, unless it opens on its own when the power goes out. The manual release should be proved at the leaf before the work is signed off.

What does the inspection record have to show?

The finding, the date, and the date the next inspection falls due. Keep it until the next inspection is recorded, and keep physical evidence with the equipment that the last inspection was carried out.

Specifying a powered door, gate or barrier?Tell us the opening, the use, and who holds the safety duties.
Contact us for a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.