ArxBridge
Theatre Security Doors
Theatre security doors for stage doors, back of house and public entrances: the grade by the room, fire and escape, access control and the whole venue.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A theatre is a building of many doors, and each door guards a different part of the night. The stage door lets the cast and the crew in after dark, the doors behind the stage guard the dressing rooms and the stores, and the doors at the front let the public in for the show. One venue takes a doorset for every part of it, and the grade of each door follows the room behind it.
The doors of a theatre must hold their line while the building is full and while it is empty. A public entrance takes a door that welcomes a crowd, a stage door takes a door that keeps the crowd out, and a door between the two takes a lock that lets the cast through and holds everyone else back.
The rules for the shared parts of a public building are set out in the fire door regulations commercial buildings guide, and the types of security doors guide works through the doors that guard each part of a building. A door ordered without the room it must guard may land on the wrong opening.
- LPS 1175 B3 / C5 / D10Forced entry periods to LPS 1175
- Stage doorThe way in for cast and crew
- FD30 / FD60Fire periods on one leaf
- One scheduleEvery theatre door on one line
The doors of one venue: stage, back of house and front of house
A theatre divides into three parts, and each part takes its own doors. The stage holds the performance, back of house holds the people and the things the performance needs, and front of house holds the public who came to watch. A door between one part and the next must hold the line between them, so the public stays in front of house and the cast stays back of house.
The doors at the front take leaves that let the public through in a crowd, with glass that lets people see through before the leaf opens and a closer that pulls the leaf shut behind each person.
The loading bay takes a door that lets scenery and cases in and out, and the bay door takes the same grade as the doors beside it, because the attack moves to the weakest part of the building. The fire door regulations leisure centres guide sets out the periods for the shared parts of a leisure building, and the fire door regulations stadiums guide covers the doors on a building that fills with a crowd.
The stage door: who comes in after dark
The stage door is the door the cast and the crew use, and it is the door the public must not use. It sits at the side of the building, away from the public entrance, and it opens for the people who work in the theatre and for no one else. A stage door that opens for anyone who knocks is no stage door at all.
The stage door takes a reader beside it, so a fob or a code opens it for the cast and the crew, and the reader belongs on the order beside the leaf, because the list behind the reader decides who may pass.
The stage door must also open from inside without a key, because the cast must get out when the alarm sounds. A panic bar to BS EN 1125 throws the latch when pushed, and the bar must work with the lock beside it, not against it, so the leaf opens for a crowd even when the power has gone. The fire door hardware guide covers the lock the key turns.
Back of house: dressing rooms, stores and the loading bay
Back of house holds the rooms the performance runs on, and each room takes a door that matches what sits behind it. The school security doors guide covers the doors on a site where keys change hands often.
The stores hold things worth taking, so a store door takes a higher grade than the dressing room beside it. A room that holds instruments, costumes or the takings from the bar takes a leaf proved against the attack the room faces, and the grade on the order follows the risk behind the leaf, not the size of the opening.
The loading bay takes a door wide enough for scenery, and the bay door takes a closer that pulls it shut after each load, because a bay door left open lets the night into the building. The fire door closers guide sets out the sizes and the fitting of closers.
Front of house: the public entrance and the box office
Front of house takes the doors the public sees, and they must hold their line while looking like part of the building. A glazed leaf lets light into the foyer and lets staff see who stands outside, and the glass beside the leaf takes the same grade as the leaf, because the attack moves to the weakest part of the frontage. The fire rated windows guide covers the windows that share the same wall.
The box office takes a door that guards the takings, and the leaf behind the counter takes a higher grade than the leaves beside it, because the room behind it holds cash.
The public entrance must open for a crowd and shut behind it, and the force to open a door on the route must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M. The security turnstiles guide covers the lobby line beside the doors, and the public entrance takes the same care with the stream of people through it.
The grade by the room: LPS 1175 B3, C5 and D10
Forced entry is proved to LPS 1175, and the category on the order follows the room behind the leaf. B3 holds three minutes, C5 holds five minutes and D10 holds ten minutes, all under Issue 8.2, dated September 2024.
B3 holds three minutes against the tool set for its category, and it suits the rooms an intruder would try first and leave fastest. A dressing room, a corridor door and a store take B3.
C5 holds five minutes, and it suits the rooms that hold something worth taking. A box office, a costume store and an instrument store take C5, because the rooms behind them hold cash or things worth carrying away. D10 holds ten minutes, and it suits the rooms that must hold longest, such as the strong room that holds the takings and the room that holds the keys to the building. The LPS 1175 vs PAS 24 guide works through the two ratings side by side, and the keeping an LPS 1175 rating valid guide sets out what breaks a rating once a door is fitted.
Fire and the way out: the leaf that holds and the leaf that opens
A theatre fills with a crowd, so the way out matters more than the way in. A leaf on an escape route must open with one push, without a key and without power, because the people behind it must get out whatever the door says. A leaf that needs a key to open from inside traps the people behind it, so the leaf takes a release that opens with one action and still holds the leaf shut against attack.
The leaf on a fire route must also hold fire back for its period, and the fire proof must sit on the same leaf as the forced entry proof. Fire resistance runs in E, EW and EI from 30 to 120 minutes under EN 1634-1, with the letters beside the number saying what the doorset held back, and the leaf, the frame and the seals go to the test as one doorset for both proofs.
A glazed leaf that must hold fire takes a pane proved with that leaf, because a pane proved in one frame can fail in another. The acoustic doors guide covers the leaves that keep a performance quiet, and the leaf that guards the auditorium takes the same care with sound as it does with fire.
Access control across the venue: readers, fobs and the key
A theatre with many doors needs its entry planned, not piled up. One fob can open the doors that belong together. A member of the cast opens the stage door and their dressing room, a cleaner opens the rooms they clean and no others, and a manager opens the whole building. The list behind the reader decides which door each fob opens, and the list is the lock.
Visitors take a different path from the cast. A visitor calls from the panel at the stage door, the person inside answers, and the release throws for that one visit.
A key is kept in the plan beside every reader, because a fob or a code is no use once the reader has no power. Each door’s fail position is settled before the order goes out, because that answer decides what the leaf does when the power fails. A leaf on an escape route opens when the power fails, while a leaf that guards cash or instruments stays shut when the power fails.
One schedule for the whole venue: every door on one line
Put the theatre door order together as one list, with a line for every door in the venue and the leaf, the rating, the lock and the reader beside each one, so the door that arrives matches the door that was ordered. A list that names one leaf for the whole venue leaves the fitter to guess which room takes which rating, and a leaf fitted to the wrong room guards the wrong thing.
Read the price beside the list before the order goes out, and mark each leaf, lock, reader and closer as it is priced. The how to specify security doors guide sets out the columns the list needs, and the security door cost factors guide works through what each step up the scale adds to the price.
The person who runs the venue walks the stage door, the dressing rooms, the auditorium doors and the plant room in turn, leaf by leaf, and tries each closer, each lock and each release as they go. A closer that no longer pulls the leaf home, a seal that has come away from its groove, or a lock that sticks is noted on the spot with the door, the part and the day beside it, so the fix is ordered before the next show. The fire door inspection checklist sets out what a visit should cover, and the security door maintenance checklist works through the doors that must hold both fire and forced entry.
| Position | Door | Proof | What to check |
|---|---|---|---|
| Stage door | Steel leaf | LPS 1175 C5 | Leaf, reader, lock |
| Public entrance | Glazed leaf | LPS 1175 B3 | Leaf, glass, closer |
| Box office | Steel leaf | LPS 1175 C5 | Leaf, lock, reader |
| Auditorium | Fire leaf | FD60 | Leaf, closer, seals |
| Store | Steel leaf | LPS 1175 B3 | Leaf, lock, finish |
A theatre door holds only as long as the room it guards and the proof behind it, so the grade, the lock and the reader must all sit on the same schedule.
What grade should a theatre door carry?
B3, C5 or D10 to LPS 1175, following the room behind the leaf, with FD30 or FD60 where the leaf must also hold fire back.
Can one leaf hold fire and forced entry?
Yes, where one leaf carries both proofs, with the leaf, the frame and the seals proved together to EN 1634-1 for fire and LPS 1175 for forced entry.
Do theatre doors need access control?
Where the venue holds rooms that only some staff should enter, a reader and a fob open the doors that belong together and keep the rest shut.
What happens when the power fails?
A door on an escape route fails safe and opens, so people can leave. A door that guards cash or instruments fails secure and stays shut, so the line holds.
Who checks the theatre doors?
The person who runs the building, on the round that walks every part of the venue. Each fault is written against the door it belongs to on the same day it is found.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.