Theatre security doors for stage doors, back of house and public entrances: the grade by the room, fire and escape, access control and the whole venue.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A theatre is a building of many doors, and each door guards a different part of the night. The stage door lets the cast and the crew in after dark, the doors behind the stage guard the dressing rooms and the stores, and the doors at the front let the public in for the show. One venue takes a doorset for every part of it, and the grade of each door follows the room behind it.

The doors of a theatre must hold their line while the building is full and while it is empty. A public entrance takes a door that welcomes a crowd, a stage door takes a door that keeps the crowd out, and a door between the two takes a lock that lets the cast through and holds everyone else back.

The rules for the shared parts of a public building are set out in the fire door regulations commercial buildings guide, and the types of security doors guide works through the doors that guard each part of a building. A door ordered without the room it must guard may land on the wrong opening.

  • LPS 1175 B3 / C5 / D10Forced entry periods to LPS 1175
  • Stage doorThe way in for cast and crew
  • FD30 / FD60Fire periods on one leaf
  • One scheduleEvery theatre door on one line

The doors of one venue: stage, back of house and front of house

A theatre divides into three parts, and each part takes its own doors. The stage holds the performance, back of house holds the people and the things the performance needs, and front of house holds the public who came to watch. A door between one part and the next must hold the line between them, so the public stays in front of house and the cast stays back of house.

The doors at the front take leaves that let the public through in a crowd, with glass that lets people see through before the leaf opens and a closer that pulls the leaf shut behind each person.

The loading bay takes a door that lets scenery and cases in and out, and the bay door takes the same grade as the doors beside it, because the attack moves to the weakest part of the building. The fire door regulations leisure centres guide sets out the periods for the shared parts of a leisure building, and the fire door regulations stadiums guide covers the doors on a building that fills with a crowd.

The stage door: who comes in after dark

The stage door is the door the cast and the crew use, and it is the door the public must not use. It sits at the side of the building, away from the public entrance, and it opens for the people who work in the theatre and for no one else. A stage door that opens for anyone who knocks is no stage door at all.

The stage door takes a reader beside it, so a fob or a code opens it for the cast and the crew, and the reader belongs on the order beside the leaf, because the list behind the reader decides who may pass.

The stage door must also open from inside without a key, because the cast must get out when the alarm sounds. A panic bar to BS EN 1125 throws the latch when pushed, and the bar must work with the lock beside it, not against it, so the leaf opens for a crowd even when the power has gone. The fire door hardware guide covers the lock the key turns.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Back of house: dressing rooms, stores and the loading bay

Back of house holds the rooms the performance runs on, and each room takes a door that matches what sits behind it. The school security doors guide covers the doors on a site where keys change hands often.

The stores hold things worth taking, so a store door takes a higher grade than the dressing room beside it. A room that holds instruments, costumes or the takings from the bar takes a leaf proved against the attack the room faces, and the grade on the order follows the risk behind the leaf, not the size of the opening.

The loading bay takes a door wide enough for scenery, and the bay door takes a closer that pulls it shut after each load, because a bay door left open lets the night into the building. The fire door closers guide sets out the sizes and the fitting of closers.

Front of house: the public entrance and the box office

Front of house takes the doors the public sees, and they must hold their line while looking like part of the building. A glazed leaf lets light into the foyer and lets staff see who stands outside, and the glass beside the leaf takes the same grade as the leaf, because the attack moves to the weakest part of the frontage. The fire rated windows guide covers the windows that share the same wall.

The box office takes a door that guards the takings, and the leaf behind the counter takes a higher grade than the leaves beside it, because the room behind it holds cash.

The public entrance must open for a crowd and shut behind it, and the force to open a door on the route must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M. The security turnstiles guide covers the lobby line beside the doors, and the public entrance takes the same care with the stream of people through it.

The grade by the room: LPS 1175 B3, C5 and D10

Forced entry is proved to LPS 1175, and the category on the order follows the room behind the leaf. B3 holds three minutes, C5 holds five minutes and D10 holds ten minutes, all under Issue 8.2, dated September 2024.

B3 holds three minutes against the tool set for its category, and it suits the rooms an intruder would try first and leave fastest. A dressing room, a corridor door and a store take B3.

C5 holds five minutes, and it suits the rooms that hold something worth taking. A box office, a costume store and an instrument store take C5, because the rooms behind them hold cash or things worth carrying away. D10 holds ten minutes, and it suits the rooms that must hold longest, such as the strong room that holds the takings and the room that holds the keys to the building. The LPS 1175 vs PAS 24 guide works through the two ratings side by side, and the keeping an LPS 1175 rating valid guide sets out what breaks a rating once a door is fitted.

Fire and the way out: the leaf that holds and the leaf that opens

A theatre fills with a crowd, so the way out matters more than the way in. A leaf on an escape route must open with one push, without a key and without power, because the people behind it must get out whatever the door says. A leaf that needs a key to open from inside traps the people behind it, so the leaf takes a release that opens with one action and still holds the leaf shut against attack.

The leaf on a fire route must also hold fire back for its period, and the fire proof must sit on the same leaf as the forced entry proof. Fire resistance runs in E, EW and EI from 30 to 120 minutes under EN 1634-1, with the letters beside the number saying what the doorset held back, and the leaf, the frame and the seals go to the test as one doorset for both proofs.

A glazed leaf that must hold fire takes a pane proved with that leaf, because a pane proved in one frame can fail in another. The acoustic doors guide covers the leaves that keep a performance quiet, and the leaf that guards the auditorium takes the same care with sound as it does with fire.

Access control across the venue: readers, fobs and the key

A theatre with many doors needs its entry planned, not piled up. One fob can open the doors that belong together. A member of the cast opens the stage door and their dressing room, a cleaner opens the rooms they clean and no others, and a manager opens the whole building. The list behind the reader decides which door each fob opens, and the list is the lock.

Visitors take a different path from the cast. A visitor calls from the panel at the stage door, the person inside answers, and the release throws for that one visit.

A key is kept in the plan beside every reader, because a fob or a code is no use once the reader has no power. Each door’s fail position is settled before the order goes out, because that answer decides what the leaf does when the power fails. A leaf on an escape route opens when the power fails, while a leaf that guards cash or instruments stays shut when the power fails.

One schedule for the whole venue: every door on one line

Put the theatre door order together as one list, with a line for every door in the venue and the leaf, the rating, the lock and the reader beside each one, so the door that arrives matches the door that was ordered. A list that names one leaf for the whole venue leaves the fitter to guess which room takes which rating, and a leaf fitted to the wrong room guards the wrong thing.

Read the price beside the list before the order goes out, and mark each leaf, lock, reader and closer as it is priced. The how to specify security doors guide sets out the columns the list needs, and the security door cost factors guide works through what each step up the scale adds to the price.

The person who runs the venue walks the stage door, the dressing rooms, the auditorium doors and the plant room in turn, leaf by leaf, and tries each closer, each lock and each release as they go. A closer that no longer pulls the leaf home, a seal that has come away from its groove, or a lock that sticks is noted on the spot with the door, the part and the day beside it, so the fix is ordered before the next show. The fire door inspection checklist sets out what a visit should cover, and the security door maintenance checklist works through the doors that must hold both fire and forced entry.

Position Door Proof What to check
Stage door Steel leaf LPS 1175 C5 Leaf, reader, lock
Public entrance Glazed leaf LPS 1175 B3 Leaf, glass, closer
Box office Steel leaf LPS 1175 C5 Leaf, lock, reader
Auditorium Fire leaf FD60 Leaf, closer, seals
Store Steel leaf LPS 1175 B3 Leaf, lock, finish

A theatre door holds only as long as the room it guards and the proof behind it, so the grade, the lock and the reader must all sit on the same schedule.

What grade should a theatre door carry?

B3, C5 or D10 to LPS 1175, following the room behind the leaf, with FD30 or FD60 where the leaf must also hold fire back.

Can one leaf hold fire and forced entry?

Yes, where one leaf carries both proofs, with the leaf, the frame and the seals proved together to EN 1634-1 for fire and LPS 1175 for forced entry.

Do theatre doors need access control?

Where the venue holds rooms that only some staff should enter, a reader and a fob open the doors that belong together and keep the rest shut.

What happens when the power fails?

A door on an escape route fails safe and opens, so people can leave. A door that guards cash or instruments fails secure and stays shut, so the line holds.

Who checks the theatre doors?

The person who runs the building, on the round that walks every part of the venue. Each fault is written against the door it belongs to on the same day it is found.

Specifying doors for a theatre?Send the door schedule and the rooms each door must guard for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.