Security Door Maintenance Checklist
What a facilities team checks on a security door: leaf, gaps, seals, closer, hinges, latch, glazing and the record that proves the rating still holds.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A security door keeps its rating only while someone checks it. A leaf that closes and latches on the day it is fitted can stand open a year later because the closer has leaked, a hinge has dropped, or the seals have been painted over. A checklist gives the facilities team a routine that catches those changes before they matter, and it gives the responsible person a record that the checks happened.
The checks below follow the door as a system: leaf, frame, gaps, seals, closer, hinges, latch, lock, glazing and the record. Each check names what to look for and what counts as a failure. The routine suits a facilities team that looks after its own buildings and an installer who returns to check work already fitted. The checks need no special tools beyond a gap gauge, a torch and a notebook, and most of them take less than a minute per door.
The law behind the routine is the Regulatory Reform (Fire Safety) Order 2005, which names a responsible person for the premises and requires a suitable system of maintenance under Article 17. A door that is never checked has no maintenance system behind it, whatever its certificate says. Our fire door inspection checklist covers the fire door checks in full, and our keeping an LPS 1175 rating valid guide covers the changes that break a security rating after handover.
- Article 17Maintenance duty under the Fire Safety Order 2005
- 4 mmUsual gap limit around a fire door leaf
- BS EN 1154Closer power sizes, minimum EN 3 on fire doors
- LPS 1175Rating covers the tested assembly, not the leaf alone
Start with the leaf: what the eye catches first
Stand in front of the door and look at the leaf before touching anything. A leaf that has been hit by a trolley, a pallet truck or a delivery cage shows the damage at once: dents in a steel leaf, splits in a timber leaf, a bowed panel, or a corner that has been knocked out of square. Damage to the face of the leaf is not only a matter of appearance. A dent beside the lock weakens the lock fixing, and a split through the edge of the leaf breaks the edge the seals press against.
Check that the leaf sits square in the frame. Look at the gap around the leaf and ask whether it is even on all four sides. A leaf that has dropped on its hinges shows a wide gap at the top on the lock side and a narrow gap at the bottom, and a closer cannot close a leaf that has dropped squarely. Look for fixings that were added after the door was fitted: hooks, signs screwed through the leaf, a new viewer, or a cable passed through a drilled hole. Each one is a change to the tested construction, and a hole drilled through a leaf without fresh evidence is a hole in the rating as well as in the door.
Check the finish. Paint, powder coating and galvanising protect the leaf from corrosion, and a finish that has worn through on the bottom edge or around the lock lets rust start where nobody looks. A steel leaf in a damp corridor or a coastal building needs its finish checked more often than a leaf in a dry office. Note the damage, write it down, and fix it before it spreads.
Gaps and seals: the small measurements that decide a rating
Measure the gap around the leaf with a gap gauge. A 4 mm gap around the leaf is the usual limit, and a doorset fitted with wider gaps has lost the performance the certificate describes. Measure at the top, both sides and the bottom, and measure with the door closed and latched, because a gap measured on a door that stands ajar tells nothing. A gap that has grown since the last check points to a hinge that has dropped or a frame that has moved, and the cause should be found before the gap is filled.
Check the intumescent seals. They sit in a groove in the frame or the leaf, and they close the gap in a fire by expanding at roughly 200 to 250 degrees. A seal that has been painted over cannot expand, a seal that has been cut short leaves a gap at the corner, and a seal that has fallen out leaves a gap all the way along the edge. Tell the decorators that seals are never to be coated, and check the seals after any painting work in the building.
Check the smoke seals where the fire strategy asks for smoke control. A fire rating on its own does not prove smoke control, so a door marked FD30S needs its smoke seals checked as well as its intumescent seals. A smoke seal that is torn, flattened or missing lets cold smoke through long before heat reaches the intumescent strip. Our fire door hardware guide sets out the hardware set, seals included, and how each part is graded.
Closers: the part that fails first
Open the door fully and let it go. The closer should bring the leaf back and hold the latch every time, without a slam and without stopping short. A closer that leaves the leaf standing open has failed, and a door that does not close has no fire performance and no security performance, whatever its certificate says. Our fire door closers guide sets out the power sizes in BS EN 1154 and how to read them, and the minimum power size on a fire door is EN 3.
Look at the closer body. A closer with a leaking body shows oil on the casing or on the floor below it, and a leaking closer will not hold its closing force for long. Check the arm and the fixings: a loose arm lets the leaf swing free, and a missing screw lets the closer twist on its fixings. Check the closing speed and the latch action. A door that closes too fast slams and frightens the people who use it, and a door that closes too slowly may not latch before the next person pushes through it.
Check any hold-open device. A hold-open device to BS EN 1155 lets a door stand open for use and releases it when the alarm sounds. Test the release at every inspection and write down that it worked. A wedge, a chair or a hook on the wall has no such release, and a door held open by one of those will stand open in a fire. Remove the wedge and fit the right device.
The closer that has lost its power: signs on the round
Open the leaf to 90 degrees, let go, and watch what happens next. A healthy closer sweeps the leaf round at a steady pace and pulls it into the latch with a click that you can hear. A closer that has lost its power lets the leaf drift, stall halfway, or stop short of the latch, and a leaf that stops short leaves the door unlatched for the rest of the day. Note the leaf that needs a push to latch, and note the leaf that slams, because a slam wears the latch and the frame at every cycle.
Check the closer body and the arm on the same visit. Oil on the closer body, a loose arm, or screws that have worked free all point to a closer that is failing, and a closer that leaks oil will only get weaker. Tighten what has loosened, wipe the body clean, and mark the closer for replacement when oil keeps appearing after a wipe. A door that serves a busy corridor wears its closer faster than a door that serves a store, so the busiest doors go first on the round, not last.
Test the opening force with a gauge rather than by feel. Below 30 N through the first 30 degrees and below 22.5 N beyond that keeps the door inside BS 8300 and Approved Document M, and a closer that has been wound up too far will push the force past those limits. Record the reading beside the door number, so the next visit can see whether the force has crept up since the last check. Our fire door closers guide covers the power sizes and the adjustments that keep a closer inside the rules.
Latches, hinges and seals: the small checks that keep the leaf honest
Work the latch with the leaf open and again with the leaf shut. A latch bolt that sticks, drags, or fails to throw fully will not hold the leaf against a push, and a latch that only throws when the leaf is lifted has a hinge problem underneath it. Check the strike plate for wear and for screws that have loosened in the frame, and check that the hinges carry the leaf without a drop at the leading edge. A leaf that has dropped by a few millimetres will bind on the frame, and a binding leaf will wear the latch at every close.
Measure the gaps around the leaf with a gauge, not by eye. A gap of 4 mm around the leaf is the usual limit, and a gap that has opened past that limit lets smoke through and lets the seal sit short of the frame. Look for seals that have shrunk, hardened, or been painted over. In a fire the seal swells shut at roughly 200 to 250 degrees, closing the gap around the leaf, so a damaged seal is a failed door, whatever the leaf looks like. Our fire door hardware guide covers the hinges, latches and seals that hold a leaf in place.
| Part | Check on the round | Mark it when |
|---|---|---|
| Closer | Sweep, latch, oil, loose arm | Leaf stalls or slams |
| Latch and strike | Full throw, wear, loose screws | Bolt sticks or drags |
| Hinges | Leaf drop, loose screws | Leaf binds on the frame |
| Seals and gaps | 4 mm gap, seal whole and fixed | Seal shrunk or painted |
| Reader and release | Reader reads, release works with power off | Reader fails or release sticks |
Write the round down before leaving the building. A record that names the door, the date and the reading is the only way the next visit can tell whether a fault is new or a fault that has been growing for months, and our fire door inspection checklist covers what a written record should hold.
Hinges, latches and locks: the hardware that holds the leaf
Check the hinges. Hinges to BS EN 1935 carry the leaf, grade 13 or grade 14, and a hinge that has dropped lets the leaf sag, so the closer cannot close it squarely. Look for missing screws, screws that have worked loose, and a hinge knuckle that has worn and lets the leaf move sideways in the frame. Tighten what is loose, replace what is worn, and write down any hinge that needed more than a turn of a screwdriver.
Check the latch. Close the door and push it gently from the pull side. The latch should hold without a push, and the door should not need a shove to latch. A latch that does not hold lets the door stand ajar, and a door that stands ajar has no fire performance. Check the strike and the keep: a keep that has been filed, bent or packed out to make a worn latch catch is a repair that hides a failure, and the latch should be replaced instead.
Check the lock and the cylinder. The cylinder should turn smoothly, the key should not stick, and the lock should throw its bolt fully. Check panic hardware where it is fitted: a bar to BS EN 1125 should cover at least 60 percent of the leaf width, and the door should open in one action, in the direction of escape, without a key. Our fire door hardware guide covers the hardware set in full, and our security door specification mistakes guide lists the hardware errors that appear after handover.
Access control and the reader that stops working
Check the reader, the credential and the record together. Present a card or fob and watch the door release. A reader that needs two or three attempts is a reader that will fail when the queue behind it is longest. Check the wider lane beside a turnstile or a speed gate, and check that the door opens in one action for wheelchairs, pushchairs and deliveries. A door that admits the right people and keeps the record of who passed is doing its job; a door that admits everyone because the reader has been bypassed is not.
Check the fail state. Ask what happens when the power fails and test it with the power off. A door that must stay locked for security and a door that must release for escape need different answers, and the answer should be written down where the facilities team can find it. Check the log: a system that keeps no record of who opened the door or when cannot answer the question when a person is found where they should not be.
Check the codes and the cards. Cancel cards that are lost, change codes when staff leave, and check the list of people who can pass each door as often as the door itself is checked. A code that has not changed since the building opened is a code that too many people know. Our security turnstiles guide works through readers, fobs and biometrics and how the lane is wired into the access system.
Glazing, beads and vision panels
Check the glass. A glazed panel lets staff see who is on the other side before opening the door, and a cracked or broken pane breaks the compartment line at the very point people look through. The glass must carry the same fire rating as the leaf where the fire strategy asks for it, with beads and seals tested as part of the doorset. Our fire rated windows guide sets out how glass, frame and beads are tested together.
Check the beads. A bead that has been swapped on site for a neater one takes the doorset outside its evidence, and a bead that has come loose lets the pane move in its frame. Fit only the bead system the test evidence names, and check that the beads are fixed all the way round the pane. Check the vision panel from both sides: a panel that is blocked by a notice, a poster or a shelf has lost the purpose it was fitted for.
Fire and security on one doorset: two checks, one visit
Many doors must do two jobs: hold fire and resist forced entry. A server room door must hold fire and resist an attack on the equipment inside, and a pharmacy store door must hold fire and resist a forced entry. The two jobs need two sets of evidence on one assembly: a fire classification to EN 1634-1 and a forced entry rating to LPS 1175 or PAS 24. A steel leaf is strong, but strength is not a security rating, and a door rated FD60 can still fail a forced entry test.
Check both ratings on the same visit. The fire check looks at gaps, seals, closer and latch. The security check looks at the leaf, the frame, the lock and the fixings. A change that breaks one rating often breaks the other: a new lock fitted without evidence breaks the fire test as well as the security test, and a leaf cut down to fit a new frame breaks both. Our dual certification guide works through how fire and security sit on one assembly, and our fire rated steel doors page covers the steel leaf that carries both jobs most often.
Check the wall the door fixes into. A rated leaf in an unrated wall gives an unrated opening, and a frame fixed into a partition that was never built to hold it will move when the door is used. Our how to specify security doors guide works through the schedule column by column, and the same habit serves a check: read the schedule, then check the door against it.
The rating after handover: changes that break the evidence
A rating belongs to the complete tested assembly, not to the leaf alone, so a rated leaf in an untested frame is not a rated doorset. That rule is what most checks fail on. A door that has been changed since it was fitted, without fresh evidence, has no proven rating. The changes that break a rating are small ones: a closer swapped for a different model, a lock changed for one that was never tested in the leaf, a vision panel added after the test, a seal replaced with a different profile, or a leaf trimmed to fit a frame that moved.
Ask for the evidence when a change is proposed, not after it is made. The test report, the classification and the hardware schedule should name the exact doorset, and a change that is not in the evidence should not be made. Our keeping an LPS 1175 rating valid guide sets out the changes that void a rating and the inspection routine that keeps it alive. File the evidence with the building records, where the next responsible person will find it.
How often to check: building the routine around the building
The Order sets no fixed interval for a security door check. Article 17 requires a suitable maintenance system, and the fire risk assessment sets the frequency. A door that opens hundreds of times a day needs checking more often than a door that opens once a week, and a door on an escape route needs checking more often than a door to a store. Build the routine around the building: list every door, grade each one by use and by risk, and set the interval from that grading.
Check after an incident. A door that has been forced, kicked, wedged or propped needs a check before it goes back into service, and a door in a building that has had a fire alarm, a break-in or a flood needs a check even if its turn has not come. Check after building work too: a fit-out, a new floor finish, or a redecoration can change a gap, a seal or a closer setting without anyone noticing. The installation page covers what a fitted doorset should arrive with, and the handover pack should name the routine the building will follow.
Records: what to write down and where to keep it
A check that is not written down cannot be proved. Write the door, the fault, the date it was found and the date it was fixed, and write who carried out the check. A record that names the door by its position in the building, not only by a number on a plan, is a record the next person can use. Keep the records with the building records, not in a drawer that leaves with the person who kept them.
Keep the evidence with the records. The test report, the classification and the hardware schedule should travel with the doorset, and the inspection routine should name where they are kept. A building that can show its checks, its faults and its fixes has a maintenance system. A building that cannot show them has only a set of doors. Our fire door inspection checklist gives the checks that catch a failing leaf before it matters, and our types of security doors guide sets out the range of doors a routine may need to cover.
| Check | What to look for | Fail | Action |
|---|---|---|---|
| Leaf and frame | Leaf square, no damage, no added holes | Dented, split or out of square | Repair or replace, record the cause |
| Gaps and seals | 4 mm gaps, seals unpainted and complete | Wide gaps, painted or missing seals | Find the cause, refit seals |
| Closer | Closes and latches every time, no leak | Stands open, leaks, slams | Adjust or replace to BS EN 1154 |
| Hinges and latch | Leaf held square, latch holds without push | Dropped leaf, latch that will not hold | Tighten or replace hardware |
| Glazing and beads | Glass intact, beads as tested | Cracked pane, swapped beads | Replace to the tested assembly |
| Records | Door, fault, dates and checker written down | No record of the check | Write it up before leaving |
A door that is never checked is a door nobody can speak for, and a rating nobody can speak for is a rating nobody can rely on.
Who should check security doors in a building?
The Regulatory Reform (Fire Safety) Order 2005 names a responsible person for the premises, and that person must make sure the checks happen. The checks themselves can be carried out by the facilities team or by an installer who knows the doorset, and the record should name who carried out each check.
How often should a security door be checked?
The Order sets no fixed interval. Article 17 requires a suitable maintenance system, and the fire risk assessment sets the frequency. A door that opens hundreds of times a day needs checking more often than a door that opens once a week, and a door on an escape route needs checking more often than a door to a store.
What breaks an LPS 1175 rating after handover?
Any change to the leaf, the frame, the glass, the seals or the hardware that is not covered by the test evidence. A closer swapped for a different model, a lock changed for one never tested in the leaf, or a vision panel added after the test all break the rating. Ask for the evidence before the change is made.
Can a facilities team adjust a closer?
Yes, where the adjustment follows the closer maker’s instructions and is written down. A closer that needs more than a small adjustment, a closer with a leaking body, or a closer that will not hold the latch should be referred to an installer, and the fault should be recorded until it is fixed.
What records should a door check produce?
The door by its position in the building, the fault found, the date it was found, the date it was fixed, and who carried out the check. Keep the records with the building records, with the test report, the classification and the hardware schedule beside them.