Fire Door Rules for Depots Explained
A depot holds vehicles, fuel and stores behind its yard gate, so each fire door takes its period from the room behind the leaf, workshop to plant room.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A depot is a yard ringed by workshops, stores and offices, where vehicles come and go through the gate all day and the fire doors are the leaves that keep a fire in the room where it began while the drivers and the fitters find the way out. The period on each door follows the room behind the leaf, because a workshop full of fuel and vehicles asks more of its doors than an office full of paperwork.
Depots share their fire rules with warehouses, and those shared rules are set out in the fire door regulations warehouses guide, while the doors that guard a warehouse yard are covered in the warehouse security doors guide. The depot order names every opening with its period and its hardware beside it, so the leaf that arrives is the leaf the room asked for.
Before a single leaf is ordered the depot writes down its fire plan, giving each opening the period it must hold and each person the route they must follow, and the order is built from that plan door by door.
- FD30 / FD60Fire periods to EN 1634-1
- E / EW / EI 30-120What the letters beside the period mean
- Sa / S200Smoke proof to BS EN 1634-3
- One listEvery depot door named
Workshops, stores and offices: a depot in three parts
A depot works as three places: the workshops where the vehicles are kept running, the stores where the parts and the fuel sit, and the offices where the jobs are booked and the records are kept. The rules follow those places, because a leaf between a workshop and a stores room must hold the fire on the side where it started while the people on the far side reach the way out.
The workshops take the doors that let vehicles and fitters pass in and out through the day, and each leaf must open for a driver who has never seen the building before. The stores take the doors that guard the stock, and each leaf must hold the fire back where the goods sit on racks and pallets.
The plan gives every opening a door of its own, so a leaf ordered for the office never ends up guarding the workshop, and a leaf ordered for the stores never ends up on the route.
FD30 and FD60 in a depot: which room takes which period
Each part of a depot asks a different period of its doors, because the load behind each leaf differs. The workshops hold vehicles and fuel, the stores hold parts in boxes and on pallets, and the plant room holds the machinery that serves the whole yard, so the period on each door follows the room and never the leaf alone.
In the furnace test to EN 1634-1 the leaf faces flames and heat while the minutes are counted, and the result pairs a number with letters. The number counts the minutes the leaf held, and the letters say whether the flames alone were stopped, the flames with some of the heat, or the flames with the heat as well.
A leaf proved for 60 minutes is heavier than one proved for 30, and the frame must be deeper to carry it, so the figure on the order rises with the period. A 30-minute leaf has no place in an opening that asks for 60, because the shortest proof in the wall is the one that gives way first.
The workshop: vehicles, fuel and the doors around them
A workshop is a wide room full of vehicles, tools and fuel, and the doors on it must hold their proof while letting fitters and vehicles pass through. A glazed leaf lets the staff see the yard beyond it without opening the leaf, and the pane takes the same proof as the leaf, because the leaf and the glass are proved as one doorset.
The fuel and the vehicles in a workshop carry a fire load of their own, and the doors between the workshop and the stores must hold the fire where it starts. A leaf between the two takes the period the stores demand, because a fire that starts among the parts must stay among the parts while the fitters move out.
For the windows set into the same walls, the fire rated windows guide names what the pane must hold, and the fire rated glass cost guide works through what the glass itself adds to the order.
Stores and the yard gate: the doors behind the workshops
The stores hold the heaviest fire load in the depot, because the parts and the fuel sit there in boxes and on racks all day. A stores leaf takes FD60, and the period follows the load in the room rather than the size of the building.
Vehicles reach the depot through the yard gate and the loading bay, so the doors there stand open for deliveries. A leaf that stands open through the day takes a hold-open device proved to BS EN 1155, which lets the leaf go the moment the alarm sounds. A leaf wedged open with a pallet holds nothing back when the fire comes.
The doors that take the deliveries in are covered in the loading bay doors guide, and the same care is taken with a depot loading bay as with a warehouse bay.
The office and the plant room: the rooms that keep the depot running
The office holds the job sheets and the records, and the leaf that guards it takes the period the room beside it takes. An office leaf takes FD60 where the office sits beside the workshops, because a fire that starts among the vehicles must not reach the records.
The plant room takes the same care, because the machinery and the electrical boards sit behind its doors all day, so a plant room leaf takes FD60. The plant room door requirements guide sets out what the plant room leaf must do.
Some depot leaves must hold fire back and hold an intruder out as well, so they carry both proofs on one doorset. Under LPS 1175 Issue 8.2 of September 2024 the forced entry categories run at three, five and ten minutes, under the names B3, C5 and D10. The LPS 1175 vs PAS 24 guide puts the two ratings side by side, the keeping an LPS 1175 rating valid guide names the faults that break a rating after fitting, and the fire and security doors dual certification guide shows how one doorset carries both proofs.
The way out when the alarm sounds: depot escape routes
The alarm in a depot turns every driver and fitter toward the exit the plan names, so the passage must stay free of pallets, bins and parked vehicles. A leaf on that passage yields to a single push, and it yields whether the lights are on or the power has gone.
A route door carries a smoke rating beside its fire period, and BS EN 1634-3 gives it: Sa where the smoke is at room temperature, S200 where it is at 200 degrees. Either mark works only where the seal meets the frame all the way round, because smoke reaches the route ahead of the flames. The smoke control doors guide works through how the doors hold smoke back while people move past them.
No leaf on one route holds for less time than the rest, because the shortest proof among them sets how long the whole route lasts. A leaf that gives way sooner than its neighbours ends the route with it, so every leaf on the route takes the period the route needs. The fire door regulations stadiums guide shows the same care taken with crowds leaving a stand.
| Position | Door | Period | What to check |
|---|---|---|---|
| Workshop | Steel leaf | FD60 | Leaf, lock, seals |
| Stores | Steel leaf | FD60 | Leaf, lock, seals |
| Office | Steel leaf | FD60 | Leaf, lock, seals |
| Plant room | Fire leaf | FD60 | Leaf, seals, gap |
| Public route | Fire leaf | FD30 | Leaf, bar, closer |
| Back of house | Steel leaf | FD60 | Leaf, closer, seals |
What keeps the period: closers, seals and gaps on depot doors
The closer on a depot leaf works harder than the closer on most other doors, because fitters pass through it all day with tools and parts. Under BS EN 1154 the smallest closer power on a fire door is EN 3, and the check is to open the leaf and watch it shut on its own. A closer that has lost its pull leaves the leaf standing open after the fitter has passed.
A 4 mm gap is kept beside the leaf, so the leaf swings free and the seal can close the opening once the leaf shuts. Once the heat passes 200 degrees the intumescent seal swells and closes the gap, unless a coat of paint over the seal stops it swelling. A seal that has slipped from its groove is noted against its door on the day it is found, with the part and the date beside it.
The hinges take the weight of the leaf through every swing of the day, and a hinge that works loose lets the leaf sink until it drags on the floor and smoke slips through the gap it leaves at the top. What the lock the key turns must do is set out in the fire door hardware guide, and the fire door closers guide covers closer sizes and fitting.
Ordering for a depot: one list for every door
The whole depot order sits on one list, and each door has its own line with the leaf, the period, the lock and the closer beside it, so what arrives matches the room it was ordered for. A list that names one leaf for the whole depot leaves the fitter to guess which part takes which period, and a leaf in the wrong workshop guards the wrong thing.
Every door on the order carries its own figure, and the figures are laid beside the schedule one door at a time before anything is signed, because a door with no figure beside it still turns up on the invoice, and a lock ordered after the doorset costs more than the same lock ordered with it. The how to specify security doors guide lists what the schedule must hold for every door, and the security door cost factors guide sets out what each step up the grade adds to the figure.
Once a week the depot manager walks the yard and tries the leaves in turn, starting at the office and finishing at the loading bay. A leaf that drags, a seal out of its groove and a closer that has lost its pull are each put down against the door where they were found, on the day they were found, and the repair is booked while the fault is still small. The record stays with the depot file, and what the visit should cover is set out in the fire door inspection checklist.
A depot leaf holds only as long as the workshops behind it and the route beside it, so the period, the release and the closer must all sit on the same list.
What period should a depot door carry?
FD30 or FD60, proved to EN 1634-1. The workshop and the stores take FD60 while the public route takes FD30, so the period follows the room, and the letters beside the minutes say what the doorset held back.
Can one leaf hold fire and forced entry?
Yes. A doorset that passed the fire test and the forced entry test together carries one report for both jobs.
Do depot doors need panic hardware?
Yes. A panic bar proved to BS EN 1125 sits on every leaf on the way out, across at least 60 percent of the leaf, so the latch throws with one push even when the person reaching it has never used the door before.
What grade should a depot stores door carry?
B3, C5 or D10 to LPS 1175, with the grade rising as the value behind the leaf rises, so the stores take a higher category than the yard gate.
Who checks the depot doors?
The depot manager walks the round that covers every door, and each visit goes into the record the depot keeps.