ArxBridge
Pharmacy Security Doors
A pharmacy holds controlled drugs behind the counter, so each door takes the grade the room behind it demands, from the counter to the stock room.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A pharmacy is a shop with a locked room inside it. The counter serves the public, and behind the counter sits the dispensary, where the controlled drugs are kept, and behind that sits the stock room, where the value waits for the shelves. Each door in the building takes the grade the room behind it demands, because the rooms hold different things.
The grade on a pharmacy door is LPS 1175, and the category follows the room. B3 holds three minutes, C5 holds five and D10 holds ten, all under Issue 8.2, dated September 2024. The counter takes the lowest grade of the three, the dispensary takes a higher one, and the room that holds the controlled drugs takes the highest.
The rules for the shared parts of a shop are set out in the fire door regulations retail guide, and the doors that guard a hospital take the same care with their stores, as the hospital security doors guide shows. The pharmacy order names every door in the building, with the grade and the lock beside each one.
- LPS 1175 B3 / C5 / D10Forced entry grades to Issue 8.2
- Controlled drugsWhat the dispensary holds
- FD30 / FD60Fire periods to EN 1634-1
- One listEvery pharmacy door named
The counter, the dispensary and the stock room: one shop, three grades
A pharmacy divides into three parts, and the grade follows the parts. The counter faces the public, the dispensary holds the drugs the counter serves, and the stock room holds what the shelves will need next week. A door between one part and the next must hold the line between them, so the drugs stay on the side where they belong and the public stays on the side where they are served.
The counter takes the doors the public sees, and each leaf must open for the staff who serve behind it and shut behind them. The dispensary takes the doors the public never sees, and each leaf must hold against the attack the drugs behind it invite. The stock room takes the doors that guard what the pharmacy runs on, and each leaf takes the grade the value behind it demands.
The order is written as one schedule before it goes out, with a line for every opening and the grade beside each one. A leaf ordered without that schedule may land where it does not belong, and a leaf in the wrong room guards the wrong thing.
Controlled drugs behind the leaf: the grade the room demands
Controlled drugs sit behind the dispensary leaf, and the grade on that leaf follows what the room holds. A room that holds drugs takes a higher category than a room that holds shelves, because the intruder who tries the dispensary is after what the pharmacy cannot replace cheaply, and the leaf must hold long enough for the alarm to be answered.
The LPS 1175 versus PAS 24 guide puts the two ratings beside each other, and the keeping an LPS 1175 rating valid guide names what breaks a rating once a door is fitted. A leaf proved to B3 where the room needs C5 arrives as a different door from the one the building needs.
SR2, SR3 and SR4 are the names the same three categories carried before Issue 8, and the name on the order is the name the product was proved under. The dispensary takes a higher category than the shop floor, because the rooms behind the leaves hold different things, and no table turns an LPS 1175 category into another standard’s rating, so the order names LPS 1175 on its own.
The counter door: the leaf the public never passes
The counter door takes the staff from the shop floor to the dispensary, and the public never passes it. The leaf opens for a member of staff with their hands full and shuts behind them without a hand on it, because a leaf left open is a door that guards nothing.
The lock on the counter door takes a reader beside the leaf, so the leaf opens for the pharmacist and no one else, and the list behind the reader decides which fob opens which door. The entry system beside the leaf is covered in the door entry systems guide.
The counter leaf must shut quietly after every member of staff who passes. The closer on the counter leaf is set to pull it home without a slam, and it is tested by opening the leaf and watching it shut on its own. The closers that pull the leaf shut are covered in the fire door closers guide, and the lock the key turns is covered in the fire door hardware guide.
The dispensary leaf: the door that guards the drugs
The dispensary leaf takes the highest grade in the shop, because the room behind it holds the controlled drugs. The leaf, the frame, the fixings and the lock face the test as one doorset, and the report names each one, so the door that arrives is the door that was proved.
A glazed leaf lets staff see through before the leaf opens, and the pane takes the same proof as the leaf beside it, because a leaf that holds while its pane fails has held nothing. The bead and the fixings round the pane are the ones the test report names.
The dispensary takes a leaf that holds fire back and holds an intruder out, so one leaf can carry both proofs. Fire is proved to EN 1634-1 in E, EW and EI from 30 to 120 minutes, and forced entry is proved to LPS 1175. The two proofs sit on the same leaf, frame and seals, proved together as one doorset. How two proofs share one doorset is worked through in the fire and security doors dual certification guide.
Stock rooms and the delivery door: where the value waits
The stock room holds the drugs and the goods the shelves will need next, and the leaf that guards it takes the grade the value behind it demands. Boxes and crates fill the room behind the leaf, so the fire load there is heavier than on the shop floor, and the leaf must hold longer than the doors the public sees.
The delivery door takes the goods in from the street, and it takes a leaf wide enough for trolleys and a closer that pulls it shut after each load. A delivery door left standing open is an invitation, so the closer is checked on every visit and the lock is tested by turning the key and watching the bolt throw.
The lock on the stock room door takes the grade the room demands, and the lock the key turns is covered in the security door locks guide. The doors that guard a shop take the same care with their stores, and the retail security doors guide sets out the doors a shopfront needs.
Fire beside security: one leaf that holds both
A pharmacy door must hold fire back for its period and hold an intruder out for its rating, with both proofs on the same leaf. The period follows the room behind the leaf, because the dispensary, the stock room and the shop floor ask different things of the leaf, and the grade follows the value behind it.
EN 1634-1 proves a doorset, and the result is a number of minutes with letters beside it. The number runs from 30 to 120, and the letters say what the doorset held back: the flames alone, the flames with some of the heat, or the flames with the heat as well. Both travel together on the order, because the number on its own names only half the proof.
The gap round the leaf stays at 4 mm, so the leaf can swing freely and the seal can close the opening. Heat wakes the intumescent seal at around 200 to 250 degrees, and a coat of paint over the seal keeps it from swelling when it matters. The round checks the gap with a gauge, and a seal that has pulled away from its groove is written against the door it belongs to.
Locks, readers and the hatch: how staff move through the shop
The staff route through a pharmacy runs from the shop floor through the counter to the dispensary and back, and each leaf on the route opens for staff and stays shut for the public. A reader beside each leaf opens it for the fob that belongs to it, and the list behind the readers decides who passes which door.
The hatch beside the counter takes the prescriptions out and the stock in, and it takes a leaf of its own, with a lock that holds it shut when the shop is closed. A hatch left open is a door by another name, so the hatch belongs on the schedule beside the doors.
The force to open a leaf on the staff route stays below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M, because staff move through the shop with their hands full. A leaf that is hard to open slows the staff who serve the counter, and a leaf that will not shut leaves the dispensary open.
The pharmacy order: one list, every leaf named
Put the pharmacy door order together as one list, with a line for every door in the shop and the leaf, the grade, the lock and the closer beside each one, so the door that arrives matches the door that was ordered. A list that names one leaf for the whole shop leaves the fitter to guess, and a leaf fitted to the wrong room guards the wrong thing.
The price is read off the list before the order goes out, with a line for every leaf, lock, closer and seal, so nothing is ordered without a price beside it. The columns the list needs are set out in the how to specify security doors guide, and the security door cost factors guide works through what each step up the scale adds to the price.
The pharmacist walks the shop door by door, from the counter to the dispensary, the stock room and the delivery door, trying each leaf as the round reaches it. A fault found on the round is written against the door it belongs to on the same day, with the part and the date beside it, so the repair is ordered while the fault is still small. What a visit should cover is set out in the fire door inspection checklist, and the doors that must hold both fire and forced entry are covered in the security door maintenance checklist.
| Position | Door | Grade | What to check |
|---|---|---|---|
| Counter | Staff leaf | LPS 1175 B3 | Leaf, reader, closer |
| Dispensary | Steel leaf | LPS 1175 C5 | Leaf, lock, seals |
| Stock room | Steel leaf | LPS 1175 C5 | Leaf, lock, closer |
| Delivery door | Wide leaf | LPS 1175 B3 | Leaf, closer, lock |
| Shop floor | Fire leaf | FD30 | Leaf, bar, closer |
A pharmacy door holds only as long as the drugs behind it and the counter beside it, so the grade, the period and the lock must all sit on the same list.
What grade should a pharmacy door carry?
The grade follows the room behind the leaf: B3, C5 or D10 to LPS 1175, with the dispensary taking a higher category than the counter beside it.
Can one leaf hold fire and forced entry?
Yes, when one doorset faced the fire test and the forced entry test together, so the leaf, the frame and the seals carry the proof for both jobs.
Do pharmacy doors need access control?
The doors behind the counter take a reader beside the leaf, so the leaf opens for staff and stays shut for the public.
What period should a dispensary door carry?
FD30 or FD60 to EN 1634-1, with E, EW or EI beside the number naming what the doorset held back, and the room behind the leaf decides which period the door takes.
Who checks the pharmacy doors?
The pharmacist in charge walks the round that covers every door, and the record of each visit stays with the shop file.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.