Fire Door Rules for Mental Health Units
A mental health unit holds a locked ward where patients move slowly, so each door takes the fire period its room demands, FD30 on the ward route, FD60 behind.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A mental health unit is a locked ward, a medicines store and a staff office behind one entrance, and the fire rules for the building follow the rooms behind each leaf. The entrance, the reception and the ward bedrooms take FD30, and the medicines store, the staff office and the plant room take FD60, because the rooms behind the ward hold drugs, keys and records that need a longer hold than the route out.
The minutes on a mental health unit leaf are counted by EN 1634-1, which runs from 30 to 120 and puts a letter beside the count to say what the leaf held back. E stands for a leaf that held flame alone, EW for a leaf that held flame with part of the heat, and EI for a leaf that held flame and heat together, so the count names the minutes and the letter names what was held back.
A mental health unit follows the same fire rules as any other building that holds people behind locked doors, and the leaf on each room takes its period from what sits behind it and from how fast the people behind it can move. The fire door regulations hospitals guide covers the fire rules for a hospital and its wards, and the fire door regulations care homes guide covers the rooms a care home keeps behind its bedrooms.
- FD30 / FD60Fire periods to EN 1634-1
- Ward bedroomWhere FD30 holds the corridor
- Sa / S200Smoke ratings to BS EN 1634-3
- One listEvery unit door named
Five rooms in a mental health unit: the period each leaf takes
Five rooms make up a mental health unit, and the period follows what each room holds. Staff and visitors come in through the entrance, the reception sits between the entrance and the ward, the medicines store keeps the drugs, the staff office keeps the keys and the records, and the plant room keeps the building running behind the ward.
FD60 sits on the medicines store, the staff office and the plant room, because the drugs, the papers and the boards behind those leaves need sixty minutes before flame reaches them. FD30 sits on the entrance, the reception and the ward bedrooms, because the people on that route are reached by staff in far less time than thirty minutes.
Every opening takes a line of its own on the order, with the leaf and the period written beside it, so no leaf is hung on guesswork and no room ends up holding fire for the wrong length of time. The table names the five rooms and the ward bedrooms, the period each one takes and the grade beside the period, so the fitter checks each leaf against its own line as it is hung.
| Room | Period | Grade | What to check |
|---|---|---|---|
| Entrance | FD30 | B3 | Leaf, glass, closer |
| Reception | FD30 | B3 | Leaf, glass, closer |
| Medicines store | FD60 | D10 | Leaf, lock, seals |
| Staff office | FD60 | C5 | Leaf, lock, seals |
| Plant room | FD60 | C5 | Leaf, lock, seals |
| Ward bedroom | FD30 | Ward grade | Leaf, lock, closer |
What FD30 and FD60 hold back on a locked ward
A fire period counts the minutes a doorset earned in the test, and the doorset means the leaf, the frame, the fixings and the lock proved as one. The report states the period the doorset holds, and the order puts that period beside the leaf, so the leaf that arrives is the leaf the room asked for. What a report behind a period must hold is named in the fire door certification guide.
A leaf on the ward may need to hold fire as well as forced entry, and one doorset carries both proofs in a single report. EN 1634-1 gives the fire minutes, LPS 1175 Issue 8.2 of September 2024 gives the forced entry grade in B3, C5 and D10, and the fire and security doors dual certification guide shows the pair proved on the same leaf.
FD60 on the medicines store, staff office and plant room
Behind the medicines store leaf sit the drugs the ward runs on, so the leaf takes FD60 and stays shut whenever no one is working inside. Sixty minutes is the hold the room asks for, because flame that reaches it takes the drugs and the records the ward cannot replace.
The staff office holds the keys, the records and the paperwork, and its leaf takes FD60, because the keys and the papers behind it open the ward each day. A leaf left standing open through the day holds nothing back, so the staff office leaf is shut each time the last person leaves the room.
The plant room holds the boards and the equipment that keep the lights and the alarms running, and its leaf takes FD60 because the boards behind it feed the whole unit. Leaves of a plant room are covered in full in the plant room fire doors guide.
Ward bedrooms: FD30 to hold the corridor clear
A patient in a ward bedroom may not move fast, and the ward door locks, so the bedroom leaf takes FD30 to hold the corridor clear while staff reach the bed. Thirty minutes is more than staff need to reach a patient on the ward, and the leaf gives them that time with the corridor still clear of flame.
A bedroom leaf must carry hardware that gives a patient nothing to tie to, and the detail of that hardware sits in the anti-ligature doors guide, which is not repeated here. The leaf takes FD30 with the grade the ward demands, and the hardware is proved with the leaf so the period is not lost by a fitting that was never tested with it.
Staff see the patient through a glazed panel in the bedroom leaf, so the leaf stays shut while the patient is watched, and the pane is proved with the leaf round it, the glass, the bead and the fixings named together in the report. What panels a fire leaf may carry is set out in the fire door vision panels guide, and steel beside timber is covered in the steel vs timber fire doors guide.
Entrance and reception: FD30 on the route staff and patients use
Both the reception leaf and the entrance leaf take FD30, because staff and patients pass through them on the way out. Half an hour is more than the people on that route need to leave, and the route behind the leaves is short, with the street at the end of it.
Where the route serves a ward, the leaves on the way out carry a push bar proved to BS EN 1125, and the bar spans at least 60 percent of the leaf width, so a person reaching the leaf in a crowd opens it with one push. What the bar must do when people push against the leaf is set out in the panic hardware guide, and the emergency exit doors guide covers the leaves on the way out.
The alarm may sound while patients who have never used the building sit in the ward, so the route to the street is signed at every turn. Nothing stands on the route, and the entrance leaf opens to one push from the first person to reach it, with the supply to the building on or off.
Smoke on the ward: Sa and S200 beside the period
People leaving the ward meet smoke before flame, so the leaves on the way out carry a smoke rating beside their fire period. The two ratings come from BS EN 1634-3, Sa for smoke at room temperature and S200 for smoke at 200 degrees, and how the route leaves keep the smoke back while the patients move past them is worked through in the smoke control doors guide.
Where a leaf must stay open through the day, a hold-open device proved to BS EN 1155 holds it, and the device lets the leaf go on its own the moment the alarm sounds. How the leaves hold the line between one part of the unit and the next is named in the fire compartmentation guide, and a chair wedged under a leaf gives it no period at all while it stands open, so the wedge is never the device that holds a fire leaf.
Closers, seals and gaps on mental health unit doors: what the period rests on
A FD60 leaf gives its hour only when the closer shuts it, the seals meet the frame and the gaps stay narrow, because flame passes through a leaf left ajar in seconds and through a wide gap soon after. BS EN 1154 proves the closer, with the power size running from EN 1 for a leaf 750 mm wide and 20 kg in weight to EN 7 for a leaf 1,600 mm wide and 160 kg in weight, and EN 3 is the minimum a fire door takes.
When heat round the frame reaches 200 to 250 degrees the seal swells and closes the gap, so flame and hot gas cannot pass. Gaps round a hung leaf measure 4 mm, and a gauge on the monthly round shows whether a gap has grown past that figure. Fitting the seal is covered in the intumescent seals guide, what the closer must do is covered in the fire door closers guide, and measuring the gaps is covered in the fire door gaps guide.
Hinges proved to BS EN 1935 hang a fire leaf, grade 13 for 200,000 cycles at 120 kg and grade 14 for 200,000 cycles at 160 kg, so the heavier leaf takes the heavier hinge. The fire door signage guide names what each sign on a fire door must say.
The vision panel that lets the night round pass without a sound
The night round moves through the ward in the small hours, and each door is checked without waking the room behind it. Staff look through the vision panel, see the person inside, and move on, and the door stays shut through the whole round. A panel that lets staff see in keeps the door shut, and a shut door is the door that holds its period.
Glass, bead and fixings are tested with the door that carries them, and a fitting put on later carries no proof of its own. The panel pages name the panels a fire door may carry, and a panel clouded by the wrong cleaning product hides the room behind it, so the round opens a door it should have left shut.
| Night check | What staff look for | Why it matters |
|---|---|---|
| Look through the panel | Person seen, room at rest | Door stays shut all night |
| Feel the door | Door meets its frame | Period rests on a shut door |
| Listen at the door | No rattle from the lock | Ward stays quiet till morning |
Hardware on a ward door is proved beside the door, and the fittings give a patient nothing to fasten a ligature to. The anti-ligature pages cover the fittings that give nothing to hold on to, and the ironmongery pages list the fittings proved with the door.
The lock turns quietly and the ward sleeps on behind the door
The lock on a ward door turns with a key held by staff, and it must turn without a click that carries down the corridor at night. A lock that grates or catches wakes the rooms beside it, so the lock is tried on the round and a lock that will not turn cleanly goes on the list the same night. A lock that turns cleanly at night is a lock that will turn cleanly when the alarm sounds. The key pages follow the keys that open every door in the building, and what happens when a key goes missing, so no door waits on a key that nobody can find.
The closer must draw the door shut without a slam, because a door that slams at 3 a.m. wakes the ward it was meant to guard. BS EN 1154 grades closers from EN 1 to EN 7, and a fire door takes EN 3 at the lowest, with the pull set so the door reaches its frame and stops, with no bang at the end of the swing. The closer pages name the grade a ward door closer must carry.
The gap round the door is even at 4 mm, and the strip in its groove is unpainted and unbroken, so the heat can start the swell near 200 degrees and finish it before 250 degrees. A strip painted over cannot grow across the gap, and a door whose strip cannot grow holds no period at all.
When the ward orders its doors, the enquiry checklist for the ward asks for the period and the lock against each room, so the ward doors that must stay quiet at night arrive with panels, locks and closers matched to the round.
A locked leaf that still has to open: the ward door on alarm
The ward leaf is locked through the day, because the people behind it must stay inside the ward, and the same leaf must open the moment the alarm sounds, because the same people must get out. That pair of demands sits on one leaf, and the lock, the closer and the seals must answer both of them at once. A leaf that holds fire but will not open on alarm fails the ward, and a leaf that opens freely but will not hold fire fails it too.
The key that opens the ward leaf sits with the member of staff on duty, and no patient holds a copy, so the leaf opens when staff reach it and stays shut at every other time. The master key guide follows the keys that open every leaf in the building, and the routine for a lost key, so a leaf is never left to a key that nobody can find.
| Demand | Part | Check |
|---|---|---|
| Hold flame for 30 minutes | Leaf and seals | Gap even at 4 mm |
| Open on alarm | Lock and closer | Leaf opens to one push |
| Give nothing to hold on to | Hardware | No point a ligature can catch |
Hardware on a ward leaf is proved beside the leaf, so a fitting added later cannot take the period off it. The anti-ligature guide covers the fittings that give a patient nothing to catch a ligature on, and the hardware guide runs through the fittings that were proved beside the leaf.
The entrance leaf and the reception leaf take FD30, since everyone on the ward passes through them on the way out and the street is a short walk from either one. A leaf on the way out must open to one push from whoever reaches it first, with the supply on or off.
No ligature point, no wedge, no hold-open a patient can reach
Where a ward leaf needs to stand open while the ward is busy, the device that holds it is proved to BS EN 1155, and it releases the leaf by itself as soon as the alarm sounds. No wedge ever holds a ward leaf, and no hold-open sits where a patient can reach it, because a leaf held open by the wrong thing holds no period at all. The closer guide explains the closers that draw the leaf shut once the device lets go, and the gap that the leaf must meet when it shuts.
A glazed panel lets staff see into a bedroom without opening the leaf, so the room stays shut while the patient inside is watched. The panel, the glass, the bead and the fixings are proved beside the leaf that carries them, and the vision panels guide names the panels a fire leaf may carry.
Each month the ward manager walks the list and works each leaf in turn, pushing it open, watching it close, looking at the seal for paint, trying the lock with its key. A fault is noted against its own leaf the day it turns up, and the leaf is mended before it is asked to hold, because a ward leaf that will not shut cannot be left until the next walk.
Pricing the ward runs from the list of leaves in the ward, and the healthcare doors quote page wants the period and the lock beside each room, so the ward leaf and the release it must give on alarm are priced as one set.
The mental health unit fire door order: every leaf, its period and its proof
The order gives every opening its own line, with the leaf, the period, the lock and the closer written beside it. One leaf named for the whole unit leaves the fitter to guess, and a leaf in the wrong room holds flame for the wrong length of time.
Each leaf on the order is read before the order is signed, because a closer that arrives after the doorset holds the job up, and a leaf with no line beside it cannot be checked when it arrives. The how to specify security doors guide sets out what the order must hold for every door.
The ward manager takes the door list round the unit once a month and tries the leaves in turn. A dragging leaf, a closer that leaves the leaf standing open or a seal that has been painted over is noted beside its own door on the day it is found, so the fault is put right before the leaf is asked to hold. The fire door inspection checklist sets out what to look for on each leaf, and the fire door maintenance guide covers the work that keeps the leaves holding.
The period on a mental health unit leaf follows the room behind it, so FD60 and FD30 must sit on the same list as the grade and the lock for each leaf.
What period should a mental health unit medicines store door carry?
FD60 to EN 1634-1, because the medicines store holds the drugs, and an hour is the hold that room demands.
What period should a ward bedroom door carry?
FD30 to EN 1634-1, because the bedroom leaf holds the corridor clear while staff reach the patient, and half an hour is the hold that room demands.
Can one leaf hold fire and forced entry?
Yes, where one leaf went through the fire test and the forced entry test, so a single report names its period and its grade.
Do mental health unit fire doors need a smoke rating?
Yes, Sa or S200 to BS EN 1634-3 sits beside the period on the leaves of the escape route, because smoke reaches the people leaving before flame does.
What happens when a fire door will not shut?
A leaf that will not shut is noted beside its own door the day the fault is found, and the unit does not wait for the next look round before the leaf is put right.