Fire Door Rules for Mental Health Units

A mental health unit holds a locked ward where patients move slowly, so each door takes the fire period its room demands, FD30 on the ward route, FD60 behind.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A mental health unit is a locked ward, a medicines store and a staff office behind one entrance, and the fire rules for the building follow the rooms behind each leaf. The entrance, the reception and the ward bedrooms take FD30, and the medicines store, the staff office and the plant room take FD60, because the rooms behind the ward hold drugs, keys and records that need a longer hold than the route out.

The minutes on a mental health unit leaf are counted by EN 1634-1, which runs from 30 to 120 and puts a letter beside the count to say what the leaf held back. E stands for a leaf that held flame alone, EW for a leaf that held flame with part of the heat, and EI for a leaf that held flame and heat together, so the count names the minutes and the letter names what was held back.

A mental health unit follows the same fire rules as any other building that holds people behind locked doors, and the leaf on each room takes its period from what sits behind it and from how fast the people behind it can move. The fire door regulations hospitals guide covers the fire rules for a hospital and its wards, and the fire door regulations care homes guide covers the rooms a care home keeps behind its bedrooms.

  • FD30 / FD60Fire periods to EN 1634-1
  • Ward bedroomWhere FD30 holds the corridor
  • Sa / S200Smoke ratings to BS EN 1634-3
  • One listEvery unit door named

Five rooms in a mental health unit: the period each leaf takes

Five rooms make up a mental health unit, and the period follows what each room holds. Staff and visitors come in through the entrance, the reception sits between the entrance and the ward, the medicines store keeps the drugs, the staff office keeps the keys and the records, and the plant room keeps the building running behind the ward.

FD60 sits on the medicines store, the staff office and the plant room, because the drugs, the papers and the boards behind those leaves need sixty minutes before flame reaches them. FD30 sits on the entrance, the reception and the ward bedrooms, because the people on that route are reached by staff in far less time than thirty minutes.

Every opening takes a line of its own on the order, with the leaf and the period written beside it, so no leaf is hung on guesswork and no room ends up holding fire for the wrong length of time. The table names the five rooms and the ward bedrooms, the period each one takes and the grade beside the period, so the fitter checks each leaf against its own line as it is hung.

Room Period Grade What to check
Entrance FD30 B3 Leaf, glass, closer
Reception FD30 B3 Leaf, glass, closer
Medicines store FD60 D10 Leaf, lock, seals
Staff office FD60 C5 Leaf, lock, seals
Plant room FD60 C5 Leaf, lock, seals
Ward bedroom FD30 Ward grade Leaf, lock, closer

What FD30 and FD60 hold back on a locked ward

A fire period counts the minutes a doorset earned in the test, and the doorset means the leaf, the frame, the fixings and the lock proved as one. The report states the period the doorset holds, and the order puts that period beside the leaf, so the leaf that arrives is the leaf the room asked for. What a report behind a period must hold is named in the fire door certification guide.

A leaf on the ward may need to hold fire as well as forced entry, and one doorset carries both proofs in a single report. EN 1634-1 gives the fire minutes, LPS 1175 Issue 8.2 of September 2024 gives the forced entry grade in B3, C5 and D10, and the fire and security doors dual certification guide shows the pair proved on the same leaf.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

FD60 on the medicines store, staff office and plant room

Behind the medicines store leaf sit the drugs the ward runs on, so the leaf takes FD60 and stays shut whenever no one is working inside. Sixty minutes is the hold the room asks for, because flame that reaches it takes the drugs and the records the ward cannot replace.

The staff office holds the keys, the records and the paperwork, and its leaf takes FD60, because the keys and the papers behind it open the ward each day. A leaf left standing open through the day holds nothing back, so the staff office leaf is shut each time the last person leaves the room.

The plant room holds the boards and the equipment that keep the lights and the alarms running, and its leaf takes FD60 because the boards behind it feed the whole unit. Leaves of a plant room are covered in full in the plant room fire doors guide.

Ward bedrooms: FD30 to hold the corridor clear

A patient in a ward bedroom may not move fast, and the ward door locks, so the bedroom leaf takes FD30 to hold the corridor clear while staff reach the bed. Thirty minutes is more than staff need to reach a patient on the ward, and the leaf gives them that time with the corridor still clear of flame.

A bedroom leaf must carry hardware that gives a patient nothing to tie to, and the detail of that hardware sits in the anti-ligature doors guide, which is not repeated here. The leaf takes FD30 with the grade the ward demands, and the hardware is proved with the leaf so the period is not lost by a fitting that was never tested with it.

Staff see the patient through a glazed panel in the bedroom leaf, so the leaf stays shut while the patient is watched, and the pane is proved with the leaf round it, the glass, the bead and the fixings named together in the report. What panels a fire leaf may carry is set out in the fire door vision panels guide, and steel beside timber is covered in the steel vs timber fire doors guide.

Entrance and reception: FD30 on the route staff and patients use

Both the reception leaf and the entrance leaf take FD30, because staff and patients pass through them on the way out. Half an hour is more than the people on that route need to leave, and the route behind the leaves is short, with the street at the end of it.

Where the route serves a ward, the leaves on the way out carry a push bar proved to BS EN 1125, and the bar spans at least 60 percent of the leaf width, so a person reaching the leaf in a crowd opens it with one push. What the bar must do when people push against the leaf is set out in the panic hardware guide, and the emergency exit doors guide covers the leaves on the way out.

The alarm may sound while patients who have never used the building sit in the ward, so the route to the street is signed at every turn. Nothing stands on the route, and the entrance leaf opens to one push from the first person to reach it, with the supply to the building on or off.

Smoke on the ward: Sa and S200 beside the period

People leaving the ward meet smoke before flame, so the leaves on the way out carry a smoke rating beside their fire period. The two ratings come from BS EN 1634-3, Sa for smoke at room temperature and S200 for smoke at 200 degrees, and how the route leaves keep the smoke back while the patients move past them is worked through in the smoke control doors guide.

Where a leaf must stay open through the day, a hold-open device proved to BS EN 1155 holds it, and the device lets the leaf go on its own the moment the alarm sounds. How the leaves hold the line between one part of the unit and the next is named in the fire compartmentation guide, and a chair wedged under a leaf gives it no period at all while it stands open, so the wedge is never the device that holds a fire leaf.

Closers, seals and gaps on mental health unit doors: what the period rests on

A FD60 leaf gives its hour only when the closer shuts it, the seals meet the frame and the gaps stay narrow, because flame passes through a leaf left ajar in seconds and through a wide gap soon after. BS EN 1154 proves the closer, with the power size running from EN 1 for a leaf 750 mm wide and 20 kg in weight to EN 7 for a leaf 1,600 mm wide and 160 kg in weight, and EN 3 is the minimum a fire door takes.

When heat round the frame reaches 200 to 250 degrees the seal swells and closes the gap, so flame and hot gas cannot pass. Gaps round a hung leaf measure 4 mm, and a gauge on the monthly round shows whether a gap has grown past that figure. Fitting the seal is covered in the intumescent seals guide, what the closer must do is covered in the fire door closers guide, and measuring the gaps is covered in the fire door gaps guide.

Hinges proved to BS EN 1935 hang a fire leaf, grade 13 for 200,000 cycles at 120 kg and grade 14 for 200,000 cycles at 160 kg, so the heavier leaf takes the heavier hinge. The fire door signage guide names what each sign on a fire door must say.

The vision panel that lets the night round pass without a sound

The night round moves through the ward in the small hours, and each door is checked without waking the room behind it. Staff look through the vision panel, see the person inside, and move on, and the door stays shut through the whole round. A panel that lets staff see in keeps the door shut, and a shut door is the door that holds its period.

Glass, bead and fixings are tested with the door that carries them, and a fitting put on later carries no proof of its own. The panel pages name the panels a fire door may carry, and a panel clouded by the wrong cleaning product hides the room behind it, so the round opens a door it should have left shut.

Night check What staff look for Why it matters
Look through the panel Person seen, room at rest Door stays shut all night
Feel the door Door meets its frame Period rests on a shut door
Listen at the door No rattle from the lock Ward stays quiet till morning

Hardware on a ward door is proved beside the door, and the fittings give a patient nothing to fasten a ligature to. The anti-ligature pages cover the fittings that give nothing to hold on to, and the ironmongery pages list the fittings proved with the door.

The lock turns quietly and the ward sleeps on behind the door

The lock on a ward door turns with a key held by staff, and it must turn without a click that carries down the corridor at night. A lock that grates or catches wakes the rooms beside it, so the lock is tried on the round and a lock that will not turn cleanly goes on the list the same night. A lock that turns cleanly at night is a lock that will turn cleanly when the alarm sounds. The key pages follow the keys that open every door in the building, and what happens when a key goes missing, so no door waits on a key that nobody can find.

The closer must draw the door shut without a slam, because a door that slams at 3 a.m. wakes the ward it was meant to guard. BS EN 1154 grades closers from EN 1 to EN 7, and a fire door takes EN 3 at the lowest, with the pull set so the door reaches its frame and stops, with no bang at the end of the swing. The closer pages name the grade a ward door closer must carry.

The gap round the door is even at 4 mm, and the strip in its groove is unpainted and unbroken, so the heat can start the swell near 200 degrees and finish it before 250 degrees. A strip painted over cannot grow across the gap, and a door whose strip cannot grow holds no period at all.

When the ward orders its doors, the enquiry checklist for the ward asks for the period and the lock against each room, so the ward doors that must stay quiet at night arrive with panels, locks and closers matched to the round.

A locked leaf that still has to open: the ward door on alarm

The ward leaf is locked through the day, because the people behind it must stay inside the ward, and the same leaf must open the moment the alarm sounds, because the same people must get out. That pair of demands sits on one leaf, and the lock, the closer and the seals must answer both of them at once. A leaf that holds fire but will not open on alarm fails the ward, and a leaf that opens freely but will not hold fire fails it too.

The key that opens the ward leaf sits with the member of staff on duty, and no patient holds a copy, so the leaf opens when staff reach it and stays shut at every other time. The master key guide follows the keys that open every leaf in the building, and the routine for a lost key, so a leaf is never left to a key that nobody can find.

Demand Part Check
Hold flame for 30 minutes Leaf and seals Gap even at 4 mm
Open on alarm Lock and closer Leaf opens to one push
Give nothing to hold on to Hardware No point a ligature can catch

Hardware on a ward leaf is proved beside the leaf, so a fitting added later cannot take the period off it. The anti-ligature guide covers the fittings that give a patient nothing to catch a ligature on, and the hardware guide runs through the fittings that were proved beside the leaf.

The entrance leaf and the reception leaf take FD30, since everyone on the ward passes through them on the way out and the street is a short walk from either one. A leaf on the way out must open to one push from whoever reaches it first, with the supply on or off.

No ligature point, no wedge, no hold-open a patient can reach

Where a ward leaf needs to stand open while the ward is busy, the device that holds it is proved to BS EN 1155, and it releases the leaf by itself as soon as the alarm sounds. No wedge ever holds a ward leaf, and no hold-open sits where a patient can reach it, because a leaf held open by the wrong thing holds no period at all. The closer guide explains the closers that draw the leaf shut once the device lets go, and the gap that the leaf must meet when it shuts.

A glazed panel lets staff see into a bedroom without opening the leaf, so the room stays shut while the patient inside is watched. The panel, the glass, the bead and the fixings are proved beside the leaf that carries them, and the vision panels guide names the panels a fire leaf may carry.

Each month the ward manager walks the list and works each leaf in turn, pushing it open, watching it close, looking at the seal for paint, trying the lock with its key. A fault is noted against its own leaf the day it turns up, and the leaf is mended before it is asked to hold, because a ward leaf that will not shut cannot be left until the next walk.

Pricing the ward runs from the list of leaves in the ward, and the healthcare doors quote page wants the period and the lock beside each room, so the ward leaf and the release it must give on alarm are priced as one set.

The mental health unit fire door order: every leaf, its period and its proof

The order gives every opening its own line, with the leaf, the period, the lock and the closer written beside it. One leaf named for the whole unit leaves the fitter to guess, and a leaf in the wrong room holds flame for the wrong length of time.

Each leaf on the order is read before the order is signed, because a closer that arrives after the doorset holds the job up, and a leaf with no line beside it cannot be checked when it arrives. The how to specify security doors guide sets out what the order must hold for every door.

The ward manager takes the door list round the unit once a month and tries the leaves in turn. A dragging leaf, a closer that leaves the leaf standing open or a seal that has been painted over is noted beside its own door on the day it is found, so the fault is put right before the leaf is asked to hold. The fire door inspection checklist sets out what to look for on each leaf, and the fire door maintenance guide covers the work that keeps the leaves holding.

The period on a mental health unit leaf follows the room behind it, so FD60 and FD30 must sit on the same list as the grade and the lock for each leaf.

What period should a mental health unit medicines store door carry?

FD60 to EN 1634-1, because the medicines store holds the drugs, and an hour is the hold that room demands.

What period should a ward bedroom door carry?

FD30 to EN 1634-1, because the bedroom leaf holds the corridor clear while staff reach the patient, and half an hour is the hold that room demands.

Can one leaf hold fire and forced entry?

Yes, where one leaf went through the fire test and the forced entry test, so a single report names its period and its grade.

Do mental health unit fire doors need a smoke rating?

Yes, Sa or S200 to BS EN 1634-3 sits beside the period on the leaves of the escape route, because smoke reaches the people leaving before flame does.

What happens when a fire door will not shut?

A leaf that will not shut is noted beside its own door the day the fault is found, and the unit does not wait for the next look round before the leaf is put right.

Specifying fire doors for a mental health unit?Send the door list with the period and the lock each room must hold for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.