Fire Door Rules for Dental Practices
A dental practice holds patients behind closed doors, so each fire door takes its period from the room behind it, from the surgery to the waiting room.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Patients sit behind closed doors in a dental practice, and the fire doors must hold the line and let people out. The leaf holds fire back for its period, and it opens for people who have never walked the route.
The period on a dental practice door follows the room behind the leaf, because the surgery, the waiting room and the plant room ask different things of the doors that guard them. The order carries the period beside each opening, so the leaf that arrives is the leaf the room needs.
The rules for the shared parts of a public building are set out in the fire door regulations commercial buildings guide, and the doors that guard a healthcare building are worked through in the fire door regulations hospitals guide. The practice order names every door in the building, with the period and the hardware beside each one.
- FD30 / FD60Fire periods to EN 1634-1
- E / EW / EI 30-120What the letters beside the period mean
- 4 mmThe gap round the leaf
- One listEvery practice door named
Surgeries, waiting rooms and the route between them
A dental practice is three buildings in one: the surgeries where the treatment runs, the waiting rooms where patients arrive and leave, and the public route that joins them. The rules follow those parts, because a door between one part and the next must hold the fire where it started while the people reach the way out.
The surgery takes the doors that let a patient in and out, and each leaf must open for people who have never seen the building before. The waiting room takes the doors that guard the patients who wait, and each leaf must hold fire back where the patients sit. The route that joins them takes the doors the patients pass through, and each leaf takes the period the escape needs.
The practice writes its fire strategy first, naming every opening with the door beside it, and the order follows the strategy, so no leaf is ordered without the room it guards behind it.
FD30 and FD60 in a dental practice: the periods each room takes
Each room in a dental practice asks a different period of its doors, because the load behind each leaf is different. The store holds the stock in boxes and crates, the surgery holds the patient on the chair, and the plant room holds the machinery that serves the building, so the period on each door follows the room, not the leaf.
A fire door is proved as a doorset to EN 1634-1, and the result is written as minutes with letters beside them. The minutes run from 30 to 120, and the letters name what the doorset held back: flames alone, flames with some heat, or flames with the heat as well. Both travel together on the order, because the minutes on their own name only half the proof.
A longer period takes a heavier leaf and a deeper frame, and the price rises with them. An opening that must hold 60 minutes takes no leaf proved for 30.
The surgery doors: leaves that shut on a patient mid-treatment
The surgery doors take the patient in and out, and each leaf must open for people who have never touched it before. The release on each leaf throws the latch with one push, and the leaf swings open when the power has gone.
A glazed leaf lets the dentist see the patient through the pane before the leaf opens, and the pane takes the same proof as the leaf, because the leaf and the glass are proved as one doorset. The bead and the fixings the test report names are written on the order beside the glass. Windows that share the same wall are covered in the fire rated windows guide, and the fire rated glass cost guide works through what the glass itself costs.
After every patient the surgery leaf has to shut quietly behind the last person out. The closer is set so the leaf comes home quietly after every patient, and the fitting is proved by opening the leaf and letting go to see it shut on its own. The fire door closers guide works through sizes and fitting, and the acoustic doors guide covers the leaves that keep a surgery quiet.
Waiting rooms and reception: the doors the public passes
The waiting room holds the patients who have arrived and the people who came with them, so the doors that guard it take a lock that holds from the inside and opens for the staff. A patient must be able to leave the room when the alarm sounds, and the staff must be able to open it when the room stands empty.
The waiting room doors take more knocks than any other leaf in the practice, from pushchairs, wheelchairs and children running past, so the leaf and its fixings must hold their line. A leaf that has been knocked out of square leaves a gap at the top, and a gap at the top lets smoke pass over the leaf.
The reception doors take the same care, because the leaf at the front of the practice must shut as surely as the leaf that guards a surgery. The gauge comes out on the round to check the gap, and a leaf that drags is written against the door it belongs to. The fire door hardware guide names what the lock the key turns must do.
The way out for patients who cannot move fast
The patients in a dental practice follow the route the building gives them, and the way out must be clear when the alarm sounds. Each door on the route opens with one push from anyone who reaches it, because the leaf must open whether the power is there or not.
Smoke seals on the route doors are proved to BS EN 1634-3: Sa for smoke at room temperature, S200 for smoke at 200 degrees. Each seal must sit against the frame all round, because smoke reaches the route before the flames do. How the doors hold smoke back while people move past them is covered in the smoke control doors guide.
Every leaf on one route takes the same period, because the route is only as strong as its weakest door. A leaf proved shorter than the leaves beside it is the leaf that fails first, so no leaf on the route takes a shorter period than the route needs. The leaves on a building that fills with patients are covered in the fire door regulations hospitals guide.
| Position | Door | Period | What to check |
|---|---|---|---|
| Surgery | Glazed leaf | FD30 | Leaf, glass, closer |
| Waiting room | Fire leaf | FD30 | Leaf, lock, seals |
| Store | Steel leaf | FD60 | Leaf, lock, seals |
| Public route | Fire leaf | FD60 | Leaf, bar, closer |
| Plant room | Fire leaf | FD60 | Leaf, seals, gap |
Closers, seals and gaps: the parts that keep the period
Every patient who walks through a dental practice door puts the closer to work, and the leaf must come home behind each one without a slam. BS EN 1154 sets EN 3 as the smallest power a fire door closer may take, and the test is simple: open the leaf and watch it shut on its own. A closer that has lost its pull leaves the leaf standing open after the patient has passed.
Keep the gap round the leaf to 4 mm, so the leaf can swing free and the seal can close the opening when the leaf shuts. The intumescent seal swells in heat at around 200 to 250 degrees, and a coat of paint over the seal keeps it from swelling when it matters. A seal that has come away from its groove goes into the record beside the door on the day it is found.
Hinges carry the leaf through every opening of the day, and each hinge carries its share of the weight. A hinge that has worked loose lets the leaf drop a little each month, until the leaf drags and the gap at the top lets smoke pass.
Forced entry in a dental practice: the grade by the room
The forced entry proof on a dental practice door is LPS 1175, and the category follows the room behind the leaf. Under Issue 8.2, dated September 2024, B3 holds three minutes, C5 holds five and D10 holds ten, and the grade on the order follows what the room holds.
A surgery door takes C5, because the intruder would try it first. A drugs store door takes D10, because the room behind it holds what the practice runs on. The records room takes C5, because it must hold longer than the waiting room beside it. The LPS 1175 vs PAS 24 guide sets the two ratings side by side, and the keeping an LPS 1175 rating valid guide names what breaks a rating once a door is fitted.
Before Issue 8 the three categories carried the names SR2, SR3 and SR4, and the order carries whichever name the product was proved under. A leaf that guards the drugs store takes a higher category than a leaf that guards a corridor, because the rooms behind them hold different things. The order names one standard on its own, and no other standard is written beside it as its equal, because no published table turns one rating into the other.
One list for the whole practice: periods, leaves and the way out
The practice order is one list, with a line for every door in the building and the leaf, the period, the lock and the closer beside each one, so the door that arrives is the door that was ordered. Where the list names one leaf for the whole practice, the fitter must guess which room takes which period, and a leaf fitted to the wrong room guards the wrong thing.
The quotation comes back against the list, line by line, and each figure is checked beside the door it belongs to. A figure left off the quotation still has to be paid, and a part fitted later costs more than the same part ordered with the building. The columns the list needs come from the how to specify security doors guide, and the security door cost factors guide works through what each step up the scale adds to the price.
Each month the practice walks its own round, surgery by surgery, and every leaf is tried before the first patient of the day arrives. A leaf that drags, a seal that has come away from its groove, or a closer that has lost its pull is noted beside the door on the day it is found, and the repair is ordered while the fault is still small. The record stays with the building file, and the fire door inspection checklist sets out what the visit should cover.
In a dental practice the period, the release and the closer decide together whether the way out works, so all three sit on the same list before the order goes out.
What period should a dental practice door carry?
FD30 or FD60 to EN 1634-1, and the letters beside the minutes name what the doorset held back. The room behind the leaf decides the period.
Can one leaf hold fire and forced entry?
Yes, where the fire test and the forced entry test were run on the same leaf, frame and seals together, so the one doorset holds the proof for both.
Do dental practice doors need panic hardware?
Yes, the leaf on the way out takes a bar proved to BS EN 1125, running across at least 60 percent of the leaf, so one push opens it for the patients behind it.
What grade should a drugs store door carry?
The grade follows the room: B3, C5 or D10 to LPS 1175, with the drugs store taking a higher category than reception.
Who checks the dental practice doors?
The practice manager walks the round that covers every door, and each visit is written into the record the building keeps.