Fire Door Vision Panels
A vision panel lets people see through a fire door before they open it. The pane, the bead and the fixings go to the test with the leaf as one doorset.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A fire door with a glazed panel lets the person on one side see the person on the other before the leaf moves. On a corridor where people walk fast and a stair core where a crowd leaves at once, the pane stops two people meeting in the doorway, and it lets a member of staff see whether the room beyond is clear before they push the leaf open.
The panel is not a hole cut in the leaf after the door is made. The pane, the bead and the fixings are proved with the leaf, the frame and the seals as one doorset, and the proof names the pane the test used. A pane fitted to a leaf that was never proved with glass leaves the door different from the one tested.
The cost of the glass itself is worked through in the fire rated glass cost guide, and the hardware beside the leaf is covered in the fire door hardware guide. A panel ordered without the leaf it belongs to may land on the wrong door, so the pane, the bead and the leaf belong on the same line of the order.
- FD30 / FD60Fire periods to EN 1634-1
- 500 to 1,500 mmThe viewing zone on the leaf
- Bead and tapeThe fixings that hold the pane
- One scheduleEvery glazed door on one line
Seeing through the leaf: why a fire door takes a pane
A corridor door opens both ways, and the person pushing it cannot see the person coming the other way. A pane in the leaf shows the corridor beyond, so the person pushing slows down and the person on the other side steps aside, and the leaf never strikes anyone.
On an escape route the pane does a second job. A member of staff at the stair door can see whether the stair is full of smoke before they open the leaf, and a person leaving a room can see whether the corridor beyond is clear before they step out.
A pane also lets light through a leaf that would otherwise shut the corridor off from the rooms beside it. A school corridor, a hospital corridor and an office floor each take leaves that let daylight reach the rooms behind them, and the pane in each leaf keeps the corridor from feeling like a tunnel. The periods for the shared parts of a school are set out in the fire door regulations schools guide, and the doors on a hospital site are covered in the hospital security doors guide.
A pane that nobody can see through has stopped doing its job, even when the glass is sound and the door still shuts. A poster goes up over it for a week and stays for a year, a notice is taped across the middle because the wall beside the door is full, and the round walks past a door that looks shut while the room beyond it cannot be seen at all. The pane is there so a person can look before pushing the door open, and a pane that is covered is a pane that has been taken away.
One poster over the pane, and the round sees nothing
The poster is put up by someone who never thinks of the pane as part of the door. It covers the glass, it hides the bead behind it, and it stays because nobody owns the job of taking it down. The round should lift every poster and notice from the glass, check the pane behind it, and put the notice on the wall beside the door instead.
The bead is the part the poster hides best. A bead that has worked loose sits behind the paper, and a bead that has been painted over cannot be seen until the paper comes off. The fixings that hold the bead are listed in the fire door hardware guide and the order names the strip the report names.
Notices breed notices. One poster on the glass gives the next person permission to add another, and the pane ends up covered edge to edge. Glazed doors get a line of their own on the round, and the pane is named on the fire door inspection checklist so the glass is looked at on every visit.
The bead sits behind a sign, so the round walks past the pane
Cleaning does its own quiet damage. The wrong product leaves a film on the glass that clouds it a little more each week, and the pane grows milky while the door still looks clean. A product made for plain glass may not suit a proved pane, so the cleaner used on the pane is named on the round sheet and nothing else is used on it.
A pane that must stand up to fire and to attack at once needs glass proved for both, and the dual certification guide shows how the two proofs sit together, while the fire rated glass cost guide lists the glass kinds the order may name.
Glass in the wall beside the door is proved to the period the glass in the door carries, and the fire rated windows guide deals with those panes, while a pane that has clouded past seeing through is noted on the round sheet beside a pane that has cracked.
| What covers the pane | What it hides | What the round does |
|---|---|---|
| Poster | The room beyond | Taken down and the pane checked |
| Notice taped across | The bead and its fixings | Notice moved to the wall beside the door |
| Wrong cleaning product | Clear glass under a film | Cleaner named on the round sheet |
Put the pane, the bead and the size on one line of the order, and the security door enquiry checklist wants the glass on it to match the glass in the report.
The glass that holds fire: what the pane must prove
The glass in a fire door is not the glass in a window. It must hold fire back for the same period as the leaf beside it, and the proof is measured in E, EW and EI from 30 to 120 minutes under EN 1634-1, the same letters that sit beside the period on the leaf.
Three kinds of glass meet a fire door: wired glass with a mesh inside it, borosilicate glass that takes heat without breaking, and laminated glass with a layer that turns opaque as it swells. Each one holds the fire in a different way, and the test report names the glass the leaf was proved with.
A pane that holds fire in one frame can fail in another, because the bead, the tape and the fixings round the pane decide whether the glass stays in place while the furnace runs. The glass, the bead and the fixings go to the test with the leaf, and the report names them all.
The bead and the tape: the fixings that hold the pane
The bead is the strip that holds the pane in the leaf, and it takes the same care as the frame. A steel bead holds the pane through the fire, while a timber bead must be proved with the leaf it sits in, and the bead that arrives with the door is the bead the test used.
Intumescent tape sits between the bead and the pane, and it swells when the heat rises, closing the gap round the glass before the flames can reach it. A bead fitted without its tape leaves the pane loose in the leaf, and a pane that rattles in its bead will not hold its line in a fire.
The fixings that hold the bead take the size and the spacing the test report names. A screw left out, or a bead fixed with the wrong fixing, leaves the pane held by less than the proof assumed, and the door that arrives is not the door that was proved.
A pane that has cracked, or a pane that took a blow in a break-in attempt, cannot stay in the leaf. The replacement must match what the test proved, glass for glass, bead for bead, size for size, because the proof belongs to the pane that was tested, not to the pane that happens to fit the hole.
A cracked pane is replaced like for like, or the proof goes with it
The first question after a crack is what glass the leaf was proved with. Wired, borosilicate or laminated, each one holds fire in its own way, and the replacement must be the same kind, because a pane of the wrong kind leaves the leaf with a proof for glass it no longer carries. The report is read before the order is written, so the glass on the order is the glass the leaf was tested with.
The bead and the tape go with the glass, because the pane is held by all three together. A replacement that names the glass but not the bead leaves the fitter to guess which strip holds the new pane, and a guess is not a proof.
The fire rated glass cost guide works through the glass kinds the order can name, so the pane that arrives is the pane the test report names. The fixings that hold the bead are checked in the fire door hardware guide, so the parts on the order match the parts in the report.
Measure the replacement against the report, not against the hole in the leaf
The hole in the leaf is the wrong measure for the replacement, because a pane cut to fill it may be larger than the test allows. The size on the order comes from the report, and the report names the largest pane the leaf may carry.
A replacement pane set higher than the one it replaces changes what the people behind the door can see, so the height is set by the people who use the door, not by the shape of the hole.
Glass in the wall beside the door takes the same period as the glass in the leaf, and the fire rated windows guide covers those panes, while a leaf that must hold fire and resist attack at once takes glass proved for both, as the dual certification guide explains.
Each visit walks the glazed doors in turn, and the fire door inspection checklist is the list the round follows, so a crack is written against the right leaf before the pane gives way.
| What is replaced | Match it to | What voids the proof |
|---|---|---|
| Glass | Kind named in the report | Wrong kind of glass |
| Bead and tape | Size and spacing in the report | Bead fitted without tape |
| Pane size | Largest size the test allows | Pane larger than the test |
The pane, the bead and the size go on the order together, and the security door enquiry checklist is the last check before it goes out, so the glass on the order is the glass the report names.
The size of the pane: what the test allows
A vision panel takes a size the test evidence allows, and a larger pane takes a different proof from a smaller one. A leaf proved with a small rectangular pane carries no proof for a leaf with a pane twice its size, because the glass, the bead and the leaf behave differently when the pane grows.
The shape of the pane follows the leaf and the room behind it. A narrow rectangular pane suits a corridor door where people pass at speed, while a circular porthole suits a door where the view matters more than the light, and the shape on the order is the shape the test proved.
A pane that runs most of the height of the leaf is a different door from a leaf with a small panel at eye height, and the order names the size, the shape and the glass together, so the door that arrives matches the door that was proved. The windows that share the same wall are covered in the fire rated windows guide, and the glass in those windows takes the same period as the doors beside them.
Where the pane sits: the height that lets people see
A vision panel sits where the people who use the door can see through it, and the viewing zone runs from 500 mm to 1,500 mm above the floor, so a child, a person in a wheelchair and a person standing can each see through the same pane.
A pane set too high shows only the ceiling to the person in a wheelchair, and a pane set too low shows only the floor to the person standing. The height on the order follows the people who use the door, not the look of the leaf.
The force to open the leaf must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M, and a leaf that is hard to open keeps people from using the door at all, pane or no pane. The closers that pull the leaf shut are covered in the fire door closers guide.
One leaf, two proofs: fire and forced entry through glass
A leaf can carry two proofs at once, because the door on an office floor must hold fire back and hold an intruder out at the same time. The fire proof is measured in E, EW and EI from 30 to 120 minutes under EN 1634-1, and the forced entry proof is LPS 1175, with B3, C5 and D10 holding three, five and ten minutes.
The glass in such a leaf takes the same grade as the leaf beside it, because an intruder who cannot break the leaf will break the pane instead. A pane proved for fire alone leaves the door open to the attack the leaf was built to resist, so the glass takes the rating the room behind the leaf demands.
Two proofs on one leaf are covered in the fire and security doors dual certification guide, and the columns the schedule needs are set out in the how to specify security doors guide. A leaf ordered with one proof when the room needs two arrives as a different door from the one the building needs.
The pane beside the leaf: sidelights, fanlights and the wall
The glass beside a fire door takes the same proof as the glass in the leaf, because a door that holds fire can still be reached through the pane beside it. A sidelight beside the leaf and a fanlight above it each take glass proved with the frame they sit in, and the report names each pane.
The windows that share the same wall take the same period as the doors beside them, because the fire moves to the weakest part of the wall. The fire rated windows guide covers those windows, and the fire rated sliding doors guide covers the leaves that close a wide opening another way.
A glazed screen beside a fire door is part of the same compartment wall, so the screen, the door and the wall are proved together, and a screen ordered without the door beside it may land on the wrong opening. The doors that hold smoke back while people move past them are covered in the smoke control doors guide.
One schedule for every glazed door: the pane on the order
Put the glazed door order together as one list, with a line for every door on the building and the pane, the bead, the glass and the fixings beside each one, so the door that arrives matches the door that was proved. A list that names one pane for the whole building leaves the fitter to guess which leaf takes which glass, and a guess is not a proof.
Check each line of the order against the list before it goes out, so no pane, bead or fixing is missed from the order. A bead or a fixing left off the order still has to be found, and cutting a pane into a leaf that is already hung takes longer than glazing the leaf before it leaves the factory. What each step up the scale adds to the price is worked through in the security door cost factors guide.
The round that looks after glazed doors walks the building in turn and looks at the pane, the bead, the fixings and the seals on each leaf. A crack in the pane, a bead that has come away from the leaf, or a seal painted over is noted beside the door it belongs to, so the repair is ordered before the pane fails. The checks a visit should cover are named in the fire door inspection checklist, and the doors that must hold both fire and forced entry are covered in the security door maintenance checklist.
| Position | Pane | Period | What to check |
|---|---|---|---|
| Stair core | Small rectangular pane | FD60 | Pane, bead, seals |
| Corridor | Rectangular pane | FD30 | Pane, bead, fixings |
| Classroom | Rectangular pane | FD30 | Pane, bead, gap |
| Office floor | Rectangular pane | FD30 | Pane, glass, closer |
| Plant room | Small pane | FD60 | Pane, bead, seals |
A vision panel is only as good as the pane, the bead and the proof behind it, so the glass, the fixings and the period belong on one line of the order.
What is a vision panel?
A glazed opening in a fire door leaf that lets people see through the door before they open it, proved with the leaf to EN 1634-1.
Does the pane hold fire as long as the leaf?
Yes, when the pane, the bead and the fixings went to the test with the leaf for the same period, FD30 or FD60.
How big can a vision panel be?
As big as the test evidence allows. A larger pane takes a different proof from a smaller one, so the size on the order is the size the test proved.
Can a vision panel sit on a security door?
Yes, where the glass takes the same grade as the leaf beside it, so the pane holds against the same attack as the door.
Who checks the panels?
The person who runs the building, on the round that looks at every door, and a crack or a loose bead is noted beside the door it belongs to.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.