A maternity unit holds mothers and newborn babies through the night, and the fire rules for the building follow the rooms behind each leaf. Delivery rooms hold births, the postnatal ward holds mothers resting with their babies, and the drugs store, staff office and plant room sit behind leaves the mothers never pass. Mothers who have just given birth move slowly and some need help to leave, so the leaves on the way out matter as much as the leaves that hold flame back.
EN 1634-1 gives the minutes on a unit leaf, testing the leaf against fire and counting how long it holds. FD30 stands for thirty minutes and FD60 for sixty, and the letter beside the minutes says what stayed out: E for flames alone, EW for flames and part of the heat, and EI for flames and heat together.
A maternity unit is not a hospice, because babies are born here rather than people receiving end-of-life care, and it is not a care home, because mothers stay for days after a birth rather than living in the building for years. The ward is not a locked ward either, so mothers move freely and the fire rules follow the rooms. The fire door rules for care homes name the fire rules for a home where residents live for years, and the fire door rules for hospitals name the rooms a hospital keeps behind its public floor.
- FD30 / FD60Fire periods to EN 1634-1
- Postnatal wardWhere mothers leave from
- Sa / S200Smoke ratings to BS EN 1634-3
- One listEvery unit door named
Seven openings on a maternity unit: a period beside each room
Seven openings make up the unit order, and the period follows what each room holds. Mothers come in through the entrance, reception watches the ward entrance, and the delivery rooms hold births while the postnatal ward holds mothers resting with their babies. The drugs store keeps the drugs, the staff office keeps the keys and the records, and the plant room keeps the building running.
The drugs store, the delivery rooms, the staff office and the plant room take FD60, because the drugs, the births, the records and the boards behind those leaves ask for sixty minutes. The entrance, reception and the postnatal ward route take FD30, because the mothers on that route can reach the street in less than thirty minutes.
Every opening gets a line of its own, leaf and period written beside the room, and the table below sets the seven rooms beside their periods and grades.
| Room | Period | Grade | What to check |
|---|---|---|---|
| Entrance | FD30 | B3 | Leaf, glass, closer |
| Reception | FD30 | B3 | Leaf, glass, closer |
| Delivery rooms | FD60 | C5 | Leaf, lock, seals |
| Postnatal ward | FD30 | B3 | Leaf, glass, closer |
| Drugs store | FD60 | D10 | Leaf, lock, seals |
| Staff office | FD60 | C5 | Leaf, lock, seals |
| Plant room | FD60 | C5 | Leaf, lock, seals |
Sixty minutes where birth happens: FD60 in the delivery rooms
Minutes belong to the whole doorset, not to the leaf alone, so leaf, frame, fixings and lock are proved together and the report states the period they hold. That period is written beside the leaf on the order, so the leaf that arrives is the one the room asked for. What the report behind a period must hold is named in the fire door certification guide.
Fire minutes from EN 1634-1 and a forced entry grade from LPS 1175 Issue 8.2 of September 2024 can sit on the same doorset, so one report names both proofs for one leaf. How the pair is proved on a single leaf is shown in the dual certification guide for fire and security doors.
Minutes alone do not tell the whole story, because the letter beside them says what the leaf stopped. E stopped flame, EW stopped flame and part of the heat, and EI stopped flame and heat together, so the letter is written on the order with the minutes.
FD60 on the drugs store, delivery rooms, staff office and plant room
The drugs store leaf takes FD60 and stays shut whenever no one is working behind it, because the drugs behind it are what the mothers are given through the day and the night. Sixty minutes is the hold that room asks for, because flame reaching it takes drugs mothers cannot do without.
Delivery room leaves take FD60 as well, because the equipment and notes behind them are what a birth depends on. A leaf left standing open through the day holds nothing back, so the last person out of the room shuts it behind them.
Keys, records and paperwork sit in the staff office, and boards and equipment that keep the lights and heating running sit in the plant room, so both leaves take FD60 because what sits behind them feeds the whole unit. The plant room leaves are covered in full by the plant room fire doors guide, and the doors that guard the plant are named in the plant room door requirements guide.
Thirty minutes on the way out: FD30 from ward to street
FD30 sits on the postnatal ward leaf and on the entrance leaf, because the mothers rest on the ward and reach the street through the entrance. Thirty minutes is more than the mothers need, and the route to the street is short.
Where the route serves mothers who move slowly, a push bar proved to BS EN 1125 sits on each leaf on the way out, and the bar runs across no less than 60 percent of the width of the leaf, so a mother who reaches it in a crowd opens it with one push. The panic hardware guide sets out what the bar must do when mothers push against the leaf, and the emergency exit doors guide covers the leaves on the way out.
A glazed panel in the reception leaf lets staff watch the mothers without opening the leaf, and the pane is proved with the leaf round it, glass, bead and fixings named together in the report. Which panels a fire leaf may carry is named in the fire door vision panels guide, and the two leaf materials are set beside each other in the steel vs timber fire doors guide.
Smoke before flame: Sa and S200 along the postnatal corridor
Mothers leaving the postnatal ward meet smoke before they meet flame, so the leaves on the way out carry a smoke rating beside their fire period. BS EN 1634-3 gives the two ratings, Sa for smoke at room temperature and S200 for smoke at 200 degrees, and the smoke control doors guide works through how the route leaves keep smoke back while mothers move past them.
Through the day a leaf that must stay open is held by a hold-open device proved to BS EN 1155, which lets the leaf go on its own the moment the alarm sounds. The fire compartmentation guide names how the leaves hold the line between one part of the unit and the next, and a chair wedged under a leaf gives it no period while it stands open.
Smoke spreads along a corridor faster than mothers walk, so the leaves between the ward and the entrance matter most. After each person through, a leaf that shuts on its own keeps the smoke on one side of it.
Closers, seals and gaps: the small parts that carry the period
An FD60 leaf holds its hour only when the closer shuts it, the seals meet the frame and the gaps stay narrow, because flame passes through a leaf left ajar in seconds and a wide gap soon after. From EN 1, for a leaf 750 mm wide and 20 kg, to EN 7, for a leaf 1,600 mm wide and 160 kg, BS EN 1154 sizes closer power, and a closer on a fire door takes at least EN 3.
Heat of 200 to 250 degrees at the frame makes the seal swell in its groove until the gap closes, so flame and hot gas cannot pass, while paint over the seal stops it swelling. A gauge checks the 4 mm gap round a hung leaf, and the monthly round shows whether any gap has grown past that figure. Fitting the seal is covered in the intumescent seals guide, what the closer must do in the fire door closers guide, and measuring the gaps in the fire door gaps guide.
Hinges proved to BS EN 1935 carry the leaf through 200,000 cycles, grade 13 at 120 kg and grade 14 at 160 kg, so the heavier leaf takes the heavier hinge. A mother must be able to push the leaf open without help, and BS 8300 with Approved Document M sets the push below 30 N through the first 30 degrees and below 22.5 N after them. What each sign must say is named in the fire door signage guide.
Moving mothers and newborns out: the route staff rehearse
The route to the street is signed at every turn, because the alarm may sound while a mother who has never used the building sits in a delivery room. Day and night the route stays clear, and the entrance leaf opens to one push from whoever reaches it first, supply on or off.
By how many people it holds, Martyns Law puts a venue in a tier, one tier for 200 to 799 people and a higher tier at 800 and above, after Royal Assent in April 2025 and with the go-live expected in spring 2027. What each tier asks for is set out in the Martyns Law guide for premises, and a unit holding 200 or more people falls in a tier it covers.
Staff walk the route with new mothers on arrival, so the way out is known before the alarm ever sounds. A mother who knows the route leaves faster, and one who has walked it once does not stop to look for the way.
Placing the maternity unit fire door order: period, grade and proof on one line
The order gives every opening in the unit a line of its own, with leaf, period, lock and closer written beside it. A leaf named once for the whole unit leaves the fitter to guess, and a leaf in the wrong room holds flame for the wrong time.
Before the order is signed it is checked leaf by leaf, because a closer ordered after the doorset arrives holds the job up, and a leaf with no line beside it cannot be checked on arrival. The how to specify security doors guide names what the order must hold.
The unit manager walks the building with the door list once a month, working each leaf in turn. A dragging leaf, a closer that leaves a leaf standing open and a seal painted over in a refit are written against their own doors that day. What to look for on each leaf is named in the fire door inspection checklist, and the work that keeps the leaves holding is named in the fire door maintenance guide.
Write the period, the grade and the lock on one line for each leaf, and match the line to its room before the leaf is hung.
What period should a maternity unit drugs store door carry?
FD60 to EN 1634-1, because the drugs store holds drugs, and an hour is the hold that room demands.
What period should a maternity unit entrance door carry?
FD30 to EN 1634-1, because the entrance is the way out and half an hour is what the public route needs.
Can one leaf hold fire and forced entry?
Yes, where one doorset passed the fire test and the forced entry test together, so a single report names the period and the grade for that leaf.
Do maternity unit fire doors need a smoke rating?
Yes, the leaves on the route carry Sa or S200 to BS EN 1634-3 beside their period, because mothers meet smoke before flame on the way out.
What happens when a fire door will not shut?
A leaf that will not shut is written up against its own door the day the fault is found, and the unit does not wait for the next look round.