ArxBridge
Fire Door Rules for Golf Clubs
A golf clubhouse holds a bar, a kitchen and locker rooms, so each door takes the fire period its room demands, FD30 on the way out and FD60 behind shut leaves.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A golf clubhouse holds a bar, a kitchen and locker rooms beside open grounds, and the fire rules for the building follow the rooms behind each leaf. Members eat and drink in the bar, change in the locker rooms and buy balls and gloves in the pro shop, while the kitchen, the back office and the plant room sit behind leaves the members never pass. Golfers move at their own pace, so the leaves on the way out matter as much as the leaves that hold flame back.
EN 1634-1 gives the minutes on a clubhouse leaf, testing it against fire and counting how long it holds. FD30 means thirty minutes and FD60 means sixty, and the letter beside the minutes says what stayed out, E for flames alone, EW for flames and part of the heat, and EI for flames and heat together.
A golf club is not a leisure centre, because members come for a round and a meal rather than for sports halls and pools, and it is not a cricket club, because the clubhouse holds a pro shop and a bar rather than a pavilion and a kit store. The fire door rules for leisure centres name the fire rules for a building full of sports halls, and the fire door rules for restaurants name the rooms a kitchen and a dining room keep behind their public floor.
- FD30 / FD60Fire periods to EN 1634-1
- Bar and kitchenWhere diners sit and cooking happens
- Sa / S200Smoke ratings to BS EN 1634-3
- One listEvery clubhouse door named
Seven openings in a golf clubhouse: a period beside each room
Seven openings make up the clubhouse order, and the period follows what each room holds. Members come in through the entrance, buy in the pro shop, eat and drink in the bar and change in the locker rooms, while the kitchen holds the cooking, the back office holds the takings and the records, and the plant room keeps the building running.
The kitchen, the back office and the plant room take FD60, because the cooking, the takings and the boards behind them ask for sixty minutes. The clubhouse entrance, the pro shop, the bar and the locker rooms take FD30, because the members on that route can reach the car park in less than thirty minutes.
Every opening gets a line of its own with leaf and period written beside the room, and the table below puts the seven rooms beside their periods and grades.
| Room | Period | Grade | What to check |
|---|---|---|---|
| Clubhouse entrance | FD30 | B3 | Leaf, glass, closer |
| Pro shop | FD30 | B3 | Leaf, glass, closer |
| Bar | FD30 | B3 | Leaf, glass, closer |
| Locker rooms | FD30 | B3 | Leaf, lock, seals |
| Kitchen | FD60 | C5 | Leaf, lock, seals |
| Back office | FD60 | C5 (D10 on safe) | Leaf, lock, seals |
| Plant room | FD60 | C5 | Leaf, lock, seals |
Sixty minutes where cooking happens: FD60 in the kitchen
A period belongs to the whole doorset rather than to the leaf alone, so leaf, frame, fixings and lock are proved together and the report states the period they hold. The period is written beside the leaf on the order, so the leaf that arrives is the one the room asked for, and the report behind a period is named in the fire door certification guide.
A forced entry grade from LPS 1175 Issue 8.2 of September 2024 can sit beside fire minutes from EN 1634-1 on the same doorset, so one report names both proofs. The dual certification guide for fire and security doors shows how the pair is proved on a single leaf.
The letter beside the minutes says what the leaf stopped, so it is written on the order with the minutes, E for flame, EW for flame and part of the heat, EI for flame and heat together.
FD60 on the back office, kitchen and plant room
The back office leaf takes FD60 and stays shut whenever no one is working behind it, because the takings and the records behind it are what the club runs on. Sixty minutes is the hold that room asks for, because flame reaching it takes the papers the club cannot do without.
Kitchen leaves take FD60 as well, because the gas, the hot surfaces and the food behind them are what a service depends on. A leaf left standing open through the day holds nothing back, so the last person out shuts it behind them.
Boards and pumps that keep the lights, the heating and the irrigation running sit in the plant room, so its leaf takes FD60 because what sits behind it feeds the clubhouse. What the plant room leaves must do is set out in the plant room fire doors guide, and the doors that guard the plant are named in the plant room door requirements guide.
Thirty minutes on the way out: FD30 from bar to car park
FD30 sits on the bar leaf, the locker room leaves and the entrance leaf, because members eat in the bar, change in the locker rooms and reach the car park through the entrance. Thirty minutes is more than the members need, and the route to the car park is short.
Where the route serves members who move slowly, a push bar proved to BS EN 1125 sits on each leaf on the way out, and the bar runs across no less than 60 percent of the leaf, so a member who reaches it in a crowd opens it with one push. The panic hardware guide sets out what the bar must do when members push against the leaf, and the emergency exit doors guide covers the leaves on the way out.
A glazed panel in the bar leaf lets staff watch the members without opening the leaf, and the pane is proved with the leaf round it, glass, bead and fixings named in the report. The panels a fire leaf may carry are named in the fire door vision panels guide, and the two leaf materials sit beside each other in the steel vs timber fire doors guide.
Smoke before flame: Sa and S200 along the clubhouse corridor
Members leaving the bar meet smoke before they meet flame, so the leaves on the way out carry a smoke rating beside the period. The two ratings come from BS EN 1634-3, Sa for smoke at room temperature and S200 for smoke at 200 degrees, and the smoke control doors guide works through how the route leaves keep smoke back while members move past them.
A leaf that must stay open through the day is held by a hold-open device proved to BS EN 1155, which lets it go on its own the moment the alarm sounds. The fire compartmentation guide names how the leaves hold the line between one part of the clubhouse and the next, and a chair wedged under a leaf gives it no period while open.
Smoke spreads along a corridor faster than members walk, so the leaves between the bar and the entrance matter most. A leaf that shuts on its own after each person through keeps the smoke on one side of it.
Closers, seals and gaps on golf club doors: what the period rests on
A closer that shuts the leaf, seals that meet the frame and gaps that stay narrow hold an FD60 leaf to its hour, because flame passes through a leaf left ajar in seconds and through a wide gap soon after. BS EN 1154 sizes closer power from EN 1, for a leaf 750 mm wide and 20 kg, to EN 7, for a leaf 1,600 mm wide and 160 kg, and a closer on a fire door takes at least EN 3.
At 200 to 250 degrees the seal swells in its groove until the gap closes, so flame and hot gas cannot pass, while paint over the seal stops it swelling. A gauge checks the 4 mm gap round a hung leaf, and the monthly round shows whether any gap has grown past that figure. How the seal is fitted is covered in the intumescent seals guide, what the closer must do in the fire door closers guide, and how the gaps are measured in the fire door gaps guide.
The leaf hangs on hinges proved to BS EN 1935 through 200,000 cycles, grade 13 carrying 120 kg and grade 14 carrying 160 kg, so the heavier leaf takes the heavier hinge. BS 8300 with Approved Document M sets the push below 30 N through the first 30 degrees and below 22.5 N after them, so a member can open the leaf without help. The signs each leaf must carry are named in the fire door signage guide.
Moving members and visitors out: the route the club rehearses
The route to the car park is signed at every turn, because the alarm may sound while a visitor who has never used the building sits in the bar. The route stays clear day and night, and the entrance leaf opens to one push from whoever reaches it first, supply on or off.
Martyns Law puts a venue in a tier by how many people it holds, one tier for 200 to 799 people and a higher tier at 800 and above, after Royal Assent in April 2025 and with the go-live expected in spring 2027. What each tier asks for is set out in the Martyns Law guide for premises, and a club holding 200 or more people falls in a tier it covers.
Bollards at the car park edge keep vehicles off the route to the entrance, and ProtectUK sets the clear gap between them at no more than 1,200 mm, with height at least 500 mm. How the bollards are chosen is covered in the choosing HVM bollards guide.
Staff walk the route with new members on arrival, so the way out is known before the alarm ever sounds.
Placing the golf club fire door order: period, grade and proof on one line
The order gives every opening a line of its own, with leaf, period, lock and closer written beside it. A leaf named once for the whole clubhouse leaves the fitter to guess, and a leaf in the wrong room holds flame for the wrong time.
The order is checked leaf by leaf before it is signed, because a closer ordered after the doorset arrives holds the job up, and a leaf with no line beside it cannot be checked on arrival. What the order must hold is named in the how to specify security doors guide.
The club manager walks the clubhouse with the door list each month, working every leaf in turn. A leaf that drags, a closer that leaves a leaf standing open and a seal painted over in a refit are all written against their own doors that day. What to look for on each leaf is named in the fire door inspection checklist, and the work that keeps the leaves holding is named in the fire door maintenance guide.
Put the period, the grade and the closer on one line for each leaf, and read the line against the room before any leaf is hung.
What period should a golf club kitchen door carry?
FD60 to EN 1634-1, because the kitchen holds gas and hot surfaces, and an hour is the hold that room demands.
What period should a golf club entrance door carry?
FD30 to EN 1634-1, because the entrance is the way out and half an hour is what the route to the car park needs.
Can a golf club leaf hold a fire period and a security grade?
Yes, when one doorset passes the fire test and the forced entry test together, so a single report names the period and the grade for that leaf.
Do golf club fire doors need a smoke rating?
Yes, the leaves on the route carry Sa or S200 to BS EN 1634-3 beside their period, because members meet smoke before flame.
What happens when a fire door will not shut?
A leaf that will not shut is written up against its own door the day the fault is found, and the club does not wait for the next look round.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.