Fire Door Rules for Cinemas
A cinema fills with audiences who do not know the building, so each fire door takes its period from the room behind it, screen by screen in the dark.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
When the lights go down in a cinema, hundreds of people sit in the dark in rooms they have never seen before, and the fire doors are the leaves that hold the fire back while those people find the way out. The period on each door follows the room behind the leaf, because a screen, a projection room and a cash office ask different things of the doors that guard them.
The rules for the shared parts of a public building are set out in the fire door regulations commercial buildings guide, and the rules for the leisure rooms beside the screens are set out in the fire door regulations leisure centres guide. The cinema order names every door in the building, with the period and the hardware beside each one.
Before any leaf is ordered, the cinema sets out which doors hold fire for how long and where each escape route runs, and the order is written from that plan, so every leaf arrives for the room it was meant to guard.
- FD30 / FD60Fire periods to EN 1634-1
- Sa / S200Smoke proof to BS EN 1634-3
- EN 3Smallest closer power to BS EN 1154
- One listEvery cinema door named
Screens, projection rooms and cash offices: one building, three periods
A cinema holds three kinds of room under one roof: screens full of people in the dark, projection rooms full of machines, and a cash office full of the day’s takings. The rules follow the rooms, because a leaf between a screen and a projection room must hold fire back while the audience on the other side finds the way out.
The screens take the doors that let an audience in and out, and each leaf must open for people who have never seen the building before. The projection rooms take the doors that guard the machines, and each leaf must hold fire back where the heat and the wiring sit. The route that joins them takes the doors the audiences pass through, and each leaf takes the period the escape needs.
Every opening is named on the plan with the door beside it, so no leaf is fitted to a room it was never meant to guard.
FD30 and FD60 in a cinema: the periods each room takes
Each part of a cinema asks a different period of its doors, because the load behind each leaf is different. The screens hold the audiences and the seats, the projection rooms hold the machines and the wiring, and the cash office holds the takings and the records, so the period on each door follows the room, not the leaf.
Under EN 1634-1 a fire door is tested for minutes and for letters together. The minutes run from 30 to 120, and the letters say what the leaf held back: flames alone, flames with some heat, or flames with the heat as well.
Weight follows the period: a leaf proved for 60 minutes weighs more than one proved for 30, and its frame runs deeper to carry it, so the quotation climbs as the period rises. A 30-minute leaf has no place in a 60-minute opening, because the leaf with the shorter proof is the one that gives way first.
The screens: audiences, seats and the doors between them
A screen is a dark room full of seats, and the doors on it must hold their proof while letting audiences pass in and out all day. A glazed leaf lets an usher see the seats beyond it without opening the leaf, and the pane takes the same proof as the leaf, because the leaf and the glass are proved as one doorset.
The seats and the fittings on a screen carry a fire load of their own, and the doors between the screen and the projection room must hold the fire where it starts. The projection room side of that wall takes the period the projection room demands, because the fire that starts among the machines must stay among the machines while the audience moves out.
The windows that share the same wall are covered in the fire rated windows guide, while the cost of the glass itself is worked through in the fire rated glass cost guide.
Projection rooms and the cash office: the doors behind the screen
The projection room takes the heaviest fire load in the cinema, because the machines and the wiring run there all day. A projection room leaf takes FD60, and the period follows the fire load, not the size of the room.
The cash office takes the same care, because the takings and the records sit behind its doors. A cash office leaf takes FD60 where the office sits beside the projection room, because the fire that starts among the machines must not reach the takings.
A projection room leaf or a cash office leaf may need a forced entry proof as well as a fire proof, because both rooms need the two together. LPS 1175 names the forced entry categories: B3 for three minutes, C5 for five and D10 for ten, all to Issue 8.2 of September 2024. The LPS 1175 vs PAS 24 guide puts the two ratings side by side, the keeping an LPS 1175 rating valid guide names what can break a rating once a door is fitted, and the fire and security doors dual certification guide works through how one doorset holds both proofs at once.
The foyer and the kiosks: the doors every audience passes
The foyer is where the audience gathers before the film, and the doors on it must hold their proof while letting people pass with tickets and drinks all evening. A leaf in the foyer takes a closer that pulls it shut after every person who passes, because a leaf left standing open holds nothing back.
The kiosks beside the foyer take the same care, because the goods behind their counters burn fast once the fire reaches them. A kiosk leaf takes the period the load behind it demands, and the seals round it must hold as long as the leaf, because a seal that has come away lets the smoke reach the foyer first.
A leaf in the foyer that must stand open through the evening takes a hold-open device proved to BS EN 1155, so the leaf shuts on its own the moment the alarm sounds. A leaf wedged open with a stool holds nothing back when the fire comes, and the wedge belongs in the store, not under the leaf.
Escape routes for a full house: the way out for audiences
When the alarm sounds, the audience follows the route the building gives them, and that route must be clear of anything that blocks it. A door on the route opens with one push from anyone who reaches it, with or without power behind it.
BS EN 1634-3 gives the route doors their smoke proof: Sa where the smoke is at room temperature, S200 where it is at 200 degrees. Smoke gets to the route before the flames do, because it travels faster than fire, and a seal holds only where it meets the frame all round. The smoke control doors guide works through how the doors hold smoke back while people move past them.
All the leaves on one route hold for the same time, because the shortest proof among them sets how long the whole route lasts. A leaf with less proof than its neighbours is the one that fails first, so every leaf on the route takes at least the period the route needs. The fire door regulations stadiums guide shows the same care taken with the crowds in a stadium.
| Position | Door | Period | What to check |
|---|---|---|---|
| Screen | Glazed leaf | FD30 | Leaf, glass, bar |
| Projection room | Steel leaf | FD60 | Leaf, lock, seals |
| Cash office | Steel leaf | FD60 | Leaf, lock, seals |
| Stock room | Steel leaf | FD60 | Leaf, lock, seals |
| Public route | Fire leaf | FD30 | Leaf, bar, closer |
| Plant room | Fire leaf | FD60 | Leaf, seals, gap |
What holds the period: the closer, the seal and the gap
The closer on a cinema leaf works harder than the closer on any other door, because audiences pass through it all evening with tickets and drinks. Under BS EN 1154 a fire door closer takes at least EN 3, and the check is to open the leaf and watch it come home on its own. A closer that has lost its pull leaves the leaf standing open after the audience has passed, and a leaf left standing open holds nothing back.
The gap beside the leaf is kept to 4 mm, so the leaf swings free and the seal can close the opening when the leaf shuts. Heat near 200 to 250 degrees makes the intumescent seal swell and close the gap, unless paint laid over the seal stops it swelling. A seal found out of its groove is written against its door on the day it is found, with the part and the date beside it.
The hinges carry the leaf through every opening of the evening, and a hinge that works loose lets the leaf sink a little month by month until it drags and the gap at the top lets smoke through. What the lock the key turns must do is named in the fire door hardware guide, and sizes and fitting for closers are worked through in the fire door closers guide.
The cinema order: every door on one list
One list carries the whole cinema order, with a line for every door and the leaf, the period, the lock and the closer beside each one, so the door that arrives is the door each room needs. A list that names one leaf for the whole cinema leaves the fitter guessing which room takes which period, and a leaf fitted to the wrong room guards the wrong thing.
Before the order goes out the quotation is read beside the list, figure by figure, so each one sits against the door it belongs to, and a figure left off still has to be paid while a part added after the order costs more than the same part ordered with the building. The how to specify security doors guide names the columns the list must hold, and the security door cost factors guide works through what each step up the scale adds to the price.
Before the first screening each week the cinema tries its leaves in turn, starting at the foyer and finishing at the projection rooms. A leaf that drags, a seal that has slipped from its groove, or a closer that has lost its pull goes in the record against its door on the day it is found, and the repair is booked while the fault is still small. The record stays with the cinema file, and what the visit should cover is set out in the fire door inspection checklist.
A cinema leaf holds only as long as the screens behind it and the route beside it, so the period, the release and the closer must all sit on the same list.
What period should a cinema door carry?
A cinema door takes FD30 or FD60, proved to EN 1634-1, and the letters beside the minutes say what the leaf held back. Which period the door takes follows the room behind the leaf.
Can one leaf hold fire and forced entry?
Yes, where the same leaf, frame and seals went through the fire test and the forced entry test together, so one report covers both jobs.
Do cinema doors need panic hardware?
Yes, the leaf on the way out takes a panic bar proved to BS EN 1125, across at least 60 percent of the leaf, so one push throws the latch for the audiences behind it.
What grade should a projection room door carry?
The grade follows the room: B3, C5 or D10 to LPS 1175, with the projection room taking a higher category than the screens beside it.
Who checks the cinema doors?
The cinema manager walks the round that covers every door, and each visit is written into the record the cinema keeps.