Forced entry, ballistic and blast ratings answer three different questions. The first asks how long a person with tools is delayed. The second asks whether a bullet is stopped. The third asks whether the building holds together under a blast load. A site that names the wrong one has bought the wrong proof.
- Forced entryDelay in minutes, by tool set
- BallisticBR and FB 1 to 7, by weapon
- BlastVXR and PXR codes, hazard A to F
- One elementCan need two or three ratings
Three threats, three questions
Start from the threat, not the number. A rating is a test result, and each test simulates one attack. Forced entry tests simulate a person breaking through with tools. Ballistic tests simulate a bullet striking glass, a door or a wall. Blast tests simulate the pressure wave and fragments from an explosive device. The three tests measure different things, and passing one proves nothing about the others.
NPSA makes the same point about its own gradings: a PROTECTION level measures delay against forcible attack, while a CLASS rating measures resistance to surreptitious attack, where the attacker wants to go unnoticed. A product can achieve a CLASS rating without providing any protection against forcible attack.
That is why the threat assessment comes first. Our guide to writing an Operational Requirement sets out the document that records the threat, the asset, the standard and the performance for each element. The NPSA guide to forced entry and blast shows the same order applied to a government site.
Forced entry ratings: delay against a person
Forced entry ratings measure delay. NPSA’s primary manual forced entry standard is MFES, the Manual Forced Entry Standard. It gives three levels, Base, Enhanced and High, for three attacker types: Novice, Knowledgeable and Expert. The tests are conducted by two attackers, and take account of their knowledge and experience, the tools available, and the method they are likely to use.
MTAS, the Marauding Terrorist Attack Standard, measures something narrower: how long a barrier holds against a marauding attacker who may carry a blade, a firearm or an explosive device in contact with the barrier. It gives five levels, from Basic to Expert. The emphasis is on delay. The standard says nothing about how a barrier is secured and opened to aid escape, so the specifier must ask about that separately.
LPS 1175 Issue 8.2, from September 2024, is the LPCB standard for intruder resistant building components. It grades products from A1 to H20, with the older SR names sitting on the same scale, SR1 at A1 and SR4 at D10. NPSA’s Forced Entry Standards Guide lists the recognised standards for facades and building elements in the UK, from BS EN 1627 through LPS 1175 to MFES and MTAS. The LPS 1175 and EN 1627 comparison explains why a grade in one standard does not translate into a grade in another.
Ballistic ratings: stopping the round
Ballistic ratings measure whether a bullet is stopped, and by what. NPSA’s guidance note on protection against bullets, published in November 2025, sets out the standards: BS EN 1063 for bullet resistant glass, and BS EN 1522 and BS EN 1523 for bullet resistant windows, doors, shutters and blinds. The same threats are used in both, with the prefixes BR for glass and FB for windows and doors. Each threat specifies a velocity and a particular bullet type.
The threat is usually defined by the weapon and the type of ammunition likely to be used. Typical bullet velocities are 300 to 500 metres per second for handguns, 700 to 1,000 metres per second for rifles, and about 600 metres per second for shotguns. The standards list seven pistol and rifle threats in ascending order of severity, plus two shotgun levels. The highest threat level is armour piercing bullets, which carry a hardened steel core designed to penetrate hard metals.
| Threat | Weapon | Bullet and velocity |
|---|---|---|
| BR/FB 1 | Rifle, .22 long rifle | Lead, 2.6 g, 360 m/s |
| BR/FB 2 | Handgun, 9 mm Luger | Ball, 8.0 g, 400 m/s |
| BR/FB 4 | Handgun, .44 Magnum | Ball, 15.6 g, 440 m/s |
| BR/FB 5 | Rifle, 5.56 mm NATO | Ball with steel penetrator, 4.0 g, 950 m/s |
| BR/FB 7 | Rifle, 7.62 mm NATO | Armour piercing, 9.8 g, 820 m/s |
| SG/FSG | Shotgun, 12 bore | Solid lead slug, 31.0 g, 420 m/s |
Glass alone proves nothing: bullet resistant glass must be mounted in a window frame that has also been tested to BS EN 1522 and BS EN 1523. Most materials that pass a level also pass the lower levels, but not always, so the test report for the exact build is the evidence. The guide to choosing a ballistic rating runs through the classes by building type.
Blast ratings: holding the load
Blast ratings measure whether a facade holds together under a blast load, and what hazard the fragments create. NPSA’s blast guidance gives three steps: identify the design threats, set the level of risk the risk owner will accept, and specify the blast performance requirement. That threat is stated as a charge size, in kilograms of TNT equivalent, with a stand-off distance.
The loading categories take the form of a code, with VXR categories covering vehicle borne devices, from 100 kg at 34 metres up to 500 kg at 25 metres. PXR categories cover person borne devices, from 3 kg at 9 metres up to 20 kg at 4 metres. The hazard letters run A to F inside, where A means the glass stays whole and F means fragments are expected, and X to Z outside, where X means no hazard and Z means high hazard. Take the lightest vehicle category, a 100 kg device at 34 metres: the code pairs that loading with the hazard letters the owner will accept, inside and outside.
Where protection is adopted, NPSA considers it may be desirable to specify an internal hazard of C or better, with an external hazard of Y or better. For doors, hazard C may be difficult, and the extra risk must be agreed and accepted by the building owner. The ISO 16933 guide explains the EXV and SB classes and the hazard ratings in full, and the blast ratings page sets out how to read a blast rating.
Which rating fits which site
The table below gives the rating family the threat points to for each site type. A site that sits in two rows needs what both rows ask for, written into the same schedule.
| Site type | Main threat | Rating family to ask for |
|---|---|---|
| Government office | Forced entry and blast | MFES or LPS 1175, plus VXR or PXR |
| Data centre | Forced entry and blast | LPS 1175 or MFES, plus VXR or PXR |
| School | Forced entry | LPS 1175 or PAS 24, by door type |
| Stadium or crowded place | Blast and forced entry | VXR or PXR, plus MFES or LPS 1175 |
| Cash handling or high value retail | Ballistic and forced entry | BR or FB, plus LPS 1175 |
A government office and a data centre point to the same two families, because both face a determined attacker and a bomb threat. A school points to forced entry alone, because the threat is a person getting in. A stadium points to blast first, because the crowd is the target. Cash handling points to ballistic first, because the threat is a weapon at close range.
The building label does not decide. The threat decides, and the threat comes from the risk assessment. The page comparing Secured by Design, NPSA and LPCB gives the same table for the three bodies a project may need, and the blast resistant doors page deals with the doorset side of a blast requirement.
A rating is an answer to one threat. A site with two threats needs two answers, written into the same schedule.
When one element needs two or three ratings
A single doorset can need a forced entry rating, a ballistic rating and a blast rating at the same time. A window can need a ballistic rating and a blast hazard rating. The ratings must be proved on the same element, as built, because a rating on the glass alone proves nothing about the frame, and a rating on the door leaf proves nothing about the fixings.
NPSA’s blast guidance makes the same point for facades: the requirement can be met by products tested under the BS EN test standards, by test reports against other standards checked by a blast specialist, or by design calculations approved by independent blast engineers. In each case the evidence must name the exact build. The blast resistant windows page covers products that carry a blast rating alongside a forced entry rating, and the blast window film guide sets out what film can and cannot do for a window already in place.
Combined ratings also change the weight and the design. NPSA notes that PROTECTION products tend to be larger, heavier and bulkier than standard products, and need additional design thought. A doorset that must delay a marauding attacker, stop a round and hold a blast load will be heavier than one that must do one of those things, and the frame, the fixings and the structure must be designed for it.
Asking for the evidence
Ask for the evidence, and name what you want. For a forced entry rating, ask for the test report and the listing: the Red Book for an LPS 1175 certificate, the CSE for an NPSA evaluation. For a ballistic rating, ask for the test report naming the exact glass, frame and fixings, with the threat level and the bullet type. For a blast rating, ask for the loading category and the hazard levels, with the test report or the design calculations behind them.
Check the claim before accepting it. Red Book Live warns that forgeries are very common, and that claims are often made that mislead the user into believing a product has approval when it does not. Phrases such as designed to, complies with and meets LPS appear on products that underwent testing, failed those tests, and are still sold as tested to the standard. Always check that the certificate or mark is valid through the search facility on the Red Book Live site.
Finally, remember what a rating cannot do. NPSA states that no security measures are proof against all threats, and that a PROTECTION product is simply delaying an attacker: given enough time undetected, all products can be breached. A rating buys time and evidence, not certainty. The vehicle security barriers due diligence guide applies the same evidence checks to barriers, and our LPS 1175 standards page lists the grades from A1 to H20.
Can one product hold all three ratings?
Yes, if it has been tested for each one. One doorset can carry all three, but each rating must be proved on that same doorset, as built.
Does a higher rating cover a lower threat?
Usually, but not always. Most materials that pass a ballistic level also pass the lower levels, yet for some unusual combinations this is not the case, so ask to see the test report for the exact build.
What is the difference between CLASS and PROTECTION?
CLASS rates resistance to surreptitious attack, where the attacker tries to go unnoticed. PROTECTION rates delay against forcible attack. A product can hold one without the other.
Is a ballistic rating the same as a blast rating?
No. A ballistic rating proves a bullet is stopped. A blast rating proves the facade holds under a blast load and limits the hazard from fragments. They are tested to different standards.
How do I check a rating claim?
Ask for the test report and check it names the exact build, then check the listing: the Red Book for an LPCB certificate, the catalogue for an NPSA evaluation. Forgeries are common, so a brochure claim alone is not proof.