Security Window Film
Security window film for shops and offices: EN 356 classes, fitting and edges, and the schedule that holds glass against forced entry on a protected frontage.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Security window film is a layer fitted to glass that holds the pane together when it is struck. A window without film shatters and falls out of the frame, leaving the opening bare, while a window with film stays in one piece and keeps the opening closed, so the intruder faces glass that will not give way.
Film is fitted to the glass that is already in place, so it suits shops and offices where the frames and the glazing stay as they are. The film, the glass and the frame must work together, because film on a pane that is loose in its frame holds the glass together but leaves the pane free to be pushed out.
The classes film can carry are set out in the ballistic glass ratings guide, and the choosing a ballistic rating guide works through the grades a pane can carry. Film that holds glass against a brick is not the same as film that holds glass against an axe, so the class follows the attack the frontage must face.
- EN 356 P1A-P8BManual attack resistance for glazing
- P6B 30-50Axe blows held by the pane
- P7B 51-70Axe blows held by the pane
- P8B 70+Axe blows held by the pane
The glass that holds together: what security film does
Film holds the fragments of a broken pane together, so the glass stays in the frame as one sheet. A pane struck by a brick cracks but does not fall, and the intruder must strike again and again to make a hole big enough to climb through, which takes time and makes noise.
The film is a clear layer, so the window keeps its light and its view. A shop front keeps the display visible, and an office keeps the daylight, while the glass behind the film takes the attack. The film should be named on the schedule beside each pane, so the pane that is filmed is the pane that was ordered.
Film suits glass that is sound and well fitted. A pane that is cracked, loose in its frame or misted between the layers takes a new pane before film is fitted, because film on damaged glass holds damaged glass together and nothing more. The fire rated windows guide covers the windows that share the same wall.
EN 356 classes: P1A to P8B and the attack film must take
Manual attack resistance is proved to EN 356, with P1A to P5A naming the classes proved by a falling ball and P6B to P8B naming the classes proved by an axe. P6B holds 30 to 50 axe blows, P7B holds 51 to 70, and P8B holds 70 or more, and the class follows the attack the frontage must face.
A shop front that faces the street at night takes a higher class than an office window on the third floor, because the risk follows the position of the pane. The class on the order should match the attack the pane must hold, and the test report should name the film, the glass and the frame as fitted.
The classes must not be mixed on one frontage without thought. A pane rated to P7B beside a pane rated to P2A leaves the frontage open at the weaker pane, so the class should be named beside each pane on the schedule, and the weakest pane on the line decides how long the frontage holds.
Where film sits on a frontage: doors, windows and the glass beside them
Film sits on the glass in doors, windows and screens, and each position asks for its own class. The glass in a door takes the same class as the leaf round it, because an attack that cannot pass the door will be tried on the glass beside it, and the security windows for schools guide covers the windows that guard a school.
Shop fronts take film on the full pane, from the sill to the head, because a pane filmed only at the bottom leaves the top open to a strike. A screen that guards a counter takes film on the side the public sees, and the bullet resistant glass page covers the glazing that takes a heavier threat.
Windows beside a door take the same care as the door itself. A window that sits beside a rated door is the way through the line when the door holds, so the film on the window must carry the same class as the door, and the frame round the window must hold the pane when it is struck.
Fitting and edges: the film is only as strong as its fixing
Film is only as strong as the edge that holds it. A film that stops short of the frame leaves the edge of the pane bare, and a strike at the edge peels the film back, so the film must run to the frame and be held there by a fixing proved with it.
The fixing at the edge matters as much as the film itself. A bead, a seal or a mechanical fixing holds the filmed pane in the frame, and the fixing should be the one the test report names, because a pane held by a bead that was never tested leaves the line open at the edge.
The glass must be clean and dry before film is fitted, because dust or damp under the film leaves bubbles that weaken the bond. The fitter should work in dry weather and leave the film to cure before the window is cleaned, and the fire rated glass cost guide works through what each step up the scale adds.
Film beside rated glass: when film is enough and when it is not
Film is not rated glass, and the two must not be confused. Rated glass is proved to EN 1063, with BR1 to BR7 naming the class and SG1 and SG2 naming the splinter guard, while film is proved to EN 356 for manual attack, and each is tested on its own standard.
A pane that must stop a round takes rated glass, not film, because film holds fragments together but does not stop a shot. The bullet resistant windows page covers the glazing that takes a ballistic threat, and the bullet resistant versus bulletproof glass guide works through the choice between glass types.
Film suits a frontage where the threat is a brick, a crowbar or an axe, and rated glass suits a frontage where the threat is heavier. The order should name the threat beside each pane, so the pane that arrives matches the pane that was proved, and the LPS 1175 windows and walling guide covers the walling that holds the same threat.
Film holds glass together, and it holds no fire back at all
It is proved against a person striking the glass, and that proof is the only proof it carries. A brick that strikes the pane cracks the glass, yet the sheet stays in the frame as one piece, because the layer binds the fragments and the opening stays shut, and the class for that attack is proved to EN 356. P6B stands for 30 to 50 axe blows, P7B for 51 to 70, and P8B for 70 or more. Fire is a different test, and a pane that must hold fire takes its period from EN 1634-1, with FD30 or FD60 beside it, so a layer on a fire pane adds no minutes to the period the pane must hold. A shop front keeps its display visible behind the layer, and an office keeps its daylight, because the layer is clear.
A filmed pane in a fire door still needs its own fire proof, and the order must not claim a fire period from the layer. One test proves the layer, the glass and the frame against the attack, and a separate test proves the glass beside the layer against fire, so the two proofs sit on separate lines and neither one stands in for the other. The class is set by the attack the frontage must face, so a street-level shop front needs a higher class than an upper-floor office window, because the risk sits with the position. The fire rated glass cost guide puts a figure on each step up the scale, and the classes a pane can carry are named in the ballistic glass ratings guide.
| Pane | Attack proof | Fire proof |
|---|---|---|
| Shop front | EN 356 class for the street | None, unless the wall asks for it |
| Door glazing | Same class as the door | FD30 or FD60 with the door |
| Screen | EN 356 class for the room | None, unless the wall asks for it |
| Office window | EN 356 class for the floor | FD30 or FD60 with the wall |
Name the fire proof and the attack proof on separate lines of the order
Each line of the order carries the pane, the class and the face, and the fire proof takes its own line beside them, so the face that is filmed is the face the test report names, and the glass that is fitted is the glass the fire proof names. The order should carry the class the pane must hold. The test report that comes with it should name the layer, the glass and the frame as fitted, because a pane proved with one layer carries no proof with another. Where the threat is a round, the order takes rated glass, because a layer binds fragments together and cannot stop a shot, and the choosing a ballistic rating guide weighs the grades a pane can carry. The frame must grip the pane when it is struck, because a layer on a loose pane keeps the glass in one piece yet leaves the whole pane free to be pushed out of the frame.
A pane that carries both proofs is one the fitter can match, and a pane that carries only one holds only one threat. For the blast side of the frontage, the layer that guards against a blast wave is covered on the blast protection window film page. School windows are taken up in the security windows for schools guide, and the walling round them in the LPS 1175 windows and walling guide.
Blast film and security film: two jobs on one pane
Blast film and security film do different jobs, and the two must not be mixed on an order. Blast film holds glass against a blast wave, and it is proved for the blast hazard, while security film holds glass against a person striking it, and it is proved to EN 356 for manual attack.
A pane that must hold both threats takes a film proved for each job, or a pane that is rated for one and filmed for the other, and the order should name each proof beside the pane. The blast protection window film page covers the film that guards against a blast wave.
Where a frontage must hold blast and forced entry at once, the two proofs sit on separate lines, because each is proved on its own test. The blast resistant windows cost and specification guide works through the windows that take a blast rating, and the film on them should name the proof it carries.
Keeping film working: cleaning, peeling and the yearly look
Film needs a yearly look, because the bond weakens where the film has lifted at the edge or been scratched by cleaning. A film that has peeled back at the corner leaves the pane bare at that corner, and a scratch across the film leaves a line where the pane can split.
Clean filmed glass with a soft cloth and a mild cleaner, and never with a blade or a scouring pad, because a blade cuts the film and leaves a line where the pane can split. The person who cleans the windows should be told which panes carry film, so the film is not cut by a cleaner who does not know it is there.
Each yearly look should check the edges, the fixing and the face of the film in turn, and each fault should be written down the same day, with the pane named and the date noted. A film that has lifted should be replaced, not patched, because a patch leaves a join where the pane can split.
The pane that is filmed on the wrong side holds nothing
Film goes on the face the attack meets, and the face matters as much as the film. A shop front takes film on the inside face, because the attack comes from the street and the film holds the fragments on the side the intruder must pass, while film on the outside face weathers, peels at the edge and leaves the pane bare. The order names the face beside each pane, so the fitter films the face the test report names and not the face that is easiest to reach. Film on a pane that faces the sun all day takes a different care from film on a shaded pane, because heat and light work on the bond at the edge, and an edge that has lifted leaves the pane bare at that corner.
A double glazed unit takes film on one pane of the unit, and the pane matters. The test report names the glass as fitted, with the film, the glass and the frame together, because a pane proved with film on the inner pane carries no proof with film on the outer one. The ballistic glass ratings guide sets out the classes a pane can carry, and the choosing a ballistic rating guide works through the grades a pane can carry.
| Glass | Face filmed | Why |
|---|---|---|
| Shop front, toughened | Inside face | Attack comes from the street |
| Double glazed unit | Named pane | Proof names that pane |
| Laminated pane | Inside face | Film holds the fragments together |
| Door glazing | Inside face | Same class as the leaf round it |
A frontage that changes its glass changes its film with it
A pane is replaced when it cracks, and the new pane takes new film of the same class. Film lifted from the old pane and stuck to the new one is not the film that was tested, because the bond that held it to the old pane is broken and the edge that held it in the frame is gone. The replacement pane is named on the schedule beside the film it takes, with the class and the face, so the pane that arrives matches the pane that was proved. The fitter who replaces the pane checks the frame as well, because a frame that has loosened will not hold the new pane when it is struck, and the edge fixing must match the one the test report names.
The schedule names the pane, the class and the face together, and the yearly look checks the film against the pane it sits on now, so a replaced pane never carries the film of the pane it replaced. The bullet resistant glass cost guide prices each step up the scale in turn, the blast protection window film page covers the film that guards against a blast wave, the security windows for schools guide covers the windows that guard a school, and the LPS 1175 windows and walling guide covers the walling that holds the same threat. A frontage that keeps its film in good order holds its line, and the yearly look is the round that keeps it that way.
One schedule for the whole frontage: every pane on one line
Put the order together as one list with a line for every pane on the frontage, naming the position, the class, the film and the fixing beside each one, so the pane that arrives matches the pane that was proved. A schedule that names one film for the whole frontage leaves the fitter to guess which pane takes which class, and a guess is not a proof.
Match every line of each quotation to the schedule before the order goes out, so no pane, film or fixing is left off the price. Anything missed from the quotation still has to be bought, and fitting it to a pane that is already in place costs more than ordering it with the film. The security door cost factors guide works through what each step up the scale adds to the price.
Keep the test reports with the film from the day it arrives, so the proof stays with the pane it belongs to, and the how to specify security doors guide sets out the columns the schedule needs. The fire rated windows cost factors guide covers the windows that share the same wall, and the warehouse security gates guide covers the gates that guard the yard behind the frontage.
| Position | Glass | Film | What to check |
|---|---|---|---|
| Shop front | Toughened glass | EN 356 P7B | Edges, fixing, face |
| Door glazing | Toughened glass | EN 356 P6B | Edges, frame, latch |
| Office window | Double glazed | EN 356 P4A | Edges, seal, face |
| Counter screen | Laminated glass | EN 356 P6B | Edges, tray, fixing |
| School window | Toughened glass | EN 356 P6B | Edges, frame, face |
Security film holds a broken pane together, so the class, the fitting and the edge fixing must all sit on the same schedule as the glass.
What does security window film do?
It holds the fragments of a broken pane together, so the glass stays in the frame as one sheet and the opening stays closed while the intruder strikes again.
What class of film do I need?
It depends on the attack. Film is proved to EN 356, with P6B holding 30 to 50 axe blows, P7B holding 51 to 70, and P8B holding 70 or more, and the class follows the risk the pane faces.
Can film replace rated glass?
No. Film holds glass against a manual attack, while rated glass is proved to EN 1063 for a ballistic threat. A pane that must stop a round takes rated glass, not film.
How is security film different from blast film?
Security film is proved to EN 356 for manual attack, while blast film is proved for the blast hazard. A pane that must hold both threats needs a film proved for each job.
Who checks security film?
The person who runs the site, on a yearly look. Each visit checks the edges, the fixing and the face of the film, and each fault is written down the same day.