Certified physical security

ArxBridge
Steel door sample in a security test frame with an assessor in a UK test laboratory

ArxBridge

Security Doors for Rehabilitation Centres

A rehabilitation centre holds residents through long stays with medicines stored on site, so each leaf takes the LPS 1175 grade its room demands.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Residents in a rehabilitation centre stay for weeks or months, working through treatment and therapy toward going home. The building holds bedrooms, treatment rooms and a store of medicines, and its leaves draw the line between the rooms anyone may enter and the rooms only staff may open. The entrance takes residents and visitors in, and the bedroom wing, the medicines store, the treatment rooms, the staff office and the plant room sit behind leaves the public never passes.

A leaf earns its grade in minutes. Issue 8.2 of LPS 1175, published in September 2024, times how long the leaf, the frame and the lock stand together against the tools the test names, and the grade on a rehabilitation centre leaf follows what sits behind it. B3 means three minutes, C5 means five and D10 means ten. Leaves ordered under the old names SR2, SR3 and SR4 match B3, C5 and D10 in that order.

A rehabilitation centre is not a hospice, because the residents here are working toward going home rather than receiving end-of-life care, and it is not a care home, because treatment rooms and therapy sit beside the bedrooms. The ward is not a locked ward either. Residents move about the building freely through the day, and the leaves lock at night rather than holding people in. The fire door regulations care homes guide covers the fire rules for a home where residents live for years, and the hospital security doors guide grades the leaves round wards where treatment happens through the day.

  • B3 / C5 / D10Grades to LPS 1175 Issue 8.2
  • Medicines storeWhere D10 sits in the centre
  • Long staysResidents work toward going home
  • One listEvery centre leaf named

Seven rooms in a rehabilitation centre: the grade each one takes

Seven rooms make up the rehabilitation centre order, and the grade on each leaf follows what the room holds. The entrance takes residents and visitors in from the street, and the bedroom wing holds the rooms where residents sleep through their stay. The medicines store holds the medicines given through the day, the treatment rooms hold the therapy and the equipment, the staff office holds the keys and the records, and the plant room keeps the heat, the light and the water running.

B3 sits on the entrance, on reception and on the bedroom wing, because those leaves stand where residents, visitors and staff pass all day and can be seen. C5 goes on the treatment rooms, on the staff office and on the plant room, because what sits behind them asks for a longer hold than the entrance. The medicines store takes D10, because the medicines behind it are the most portable thing the centre holds, and its leaf stays shut and locked when no one is working behind it.

The order names every opening on its own line, with the leaf, the grade and the minutes written beside it, and the fitter checks each leaf against that line as it is hung. The table below puts the seven rooms beside their grades.

Room Grade Minutes What to check
Entrance B3 3 Leaf, lock, closer
Reception B3 3 Leaf, lock, seals
Bedroom wing B3 3 Leaf, lock, closer
Medicines store D10 10 Leaf, lock, hinges
Treatment rooms C5 5 Leaf, lock, reader
Staff office C5 5 Leaf, lock, reader
Plant room C5 5 Leaf, lock, seals

A centre leaf can hold fire as well as forced entry, and one doorset can carry both proofs in a single report. EN 1634-1 gives the fire count, running from 30 minutes to 120, and the letter with the count says what stayed out: E for flame alone, EW for flame with part of the heat, and EI for flame and heat together. The fire and security doors dual certification guide shows the pair proved on one leaf, the LPS 1175 Issue 8 explained guide sets out what Issue 8.2 changed, and the SR2 vs SR3 vs SR4 guide puts the old names beside the new grades.

The entrance and reception: B3 where residents and visitors arrive

Residents arrive for admission with bags and family beside them, and visitors come through the day, so the entrance leaf opens and shuts for people with their hands full rather than for one person at a time. The closer must bring the leaf home after each person through without a slam that carries down the corridor.

Three minutes is the hold the entrance takes, because the reception desk watches it through the day, and that time lets staff shut the reception leaf and call for help. The lock turns with a key from the street and with a thumb turn from inside, so the last person to leave at night secures the leaf without hunting for a key.

Reception looks through a glazed panel in the entrance leaf before opening it, so a visitor is seen before the leaf moves. The panel is proved with the leaf round it, and the report names the glass, the bead and the fixings beside the leaf. The door entry systems guide covers the panels and the readers that guard an entrance, and the emergency exit doors guide covers the leaves on the way out.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

The bedroom wing: B3 leaves residents can open themselves

Each bedroom in the wing belongs to one resident for the length of the stay, and its leaf must shut for privacy yet open for staff without delay. A thumb turn on the bedroom side lets the resident shut the leaf without a key, while a key on the corridor side lets staff open it.

A small glazed panel set high in the bedroom leaf lets staff look in without opening the leaf and waking the resident, and the bed stays out of sight. The fire door vision panels guide names the panels a leaf may carry, and the fire door regulations care homes guide covers the bedroom leaf a care home fits.

Residents on the bedroom wing may push a leaf while carrying a bag or leaning on a stick, so the leaf must move under a light hand. BS 8300 and Approved Document M put the force below 30 N through the first 30 degrees and below 22.5 N after them.

How does a resident open a bedroom leaf without a key?

A resident opens the bedroom leaf alone, because the thumb turn inside needs no key, and staff carry the key that opens the same leaf from the corridor. The leaf shuts for privacy yet opens for staff without delay, so a resident who wants the room to themselves can shut it, and a member of staff who needs to reach them can open it at once. A bedroom leaf that shuts for privacy must still open from the corridor without a wait, because a resident who needs help cannot wait for a key to be found.

A reader beside the treatment room leaf answers only the cards the list names, so the room opens for the therapist whose session it is and stays shut for everyone else. The guide to access control doors names the readers and cards that stand guard on a treatment room leaf.

Leaf Who opens it How
Bedroom wing Resident and staff Thumb turn inside, key outside
Medicines store Nurse in charge Key only, list beside leaf
Treatment rooms Therapist Card reader

A panel high in the bedroom leaf lets staff see whether the room is in use without swinging the leaf open, and it sits high enough that the bed stays out of sight. The guide to fire door vision panels lists the panels a bedroom leaf may carry and the proof each one needs.

A resident may push the bedroom leaf with a bag in one hand and a stick in the other, so the leaf answers a light push, with the force under 30 N across the first 30 degrees of swing and under 22.5 N after that, as BS 8300 and Approved Document M set it.

Every bedroom leaf in the wing opens to the same staff key

The order is written opening by opening, and each line names the leaf, its grade and its minutes, so the fitter can match every leaf to its line before a single leaf is hung. A leaf that never made the list can end up guarding the wrong opening, and a C5 leaf on the medicines store would hold for five minutes where the order asks for ten. The guide to how to specify security doors sets out what each line of the order must carry.

The way out runs through leaves that free themselves to a single push, so the first person to reach them gets out whether the power is on or off. The emergency exit doors guide names the leaves that must free themselves when the alarm sounds.

The lock on the medicines store leaf answers the nurse in charge, and a list beside the leaf names the other hands that may open it, so a key that opens the store opens nothing else in the centre. The locks guide sets out the lock a medicines store leaf needs and the key that opens it from the corridor.

An enquiry for the centre starts with the rooms themselves, and the healthcare doors quote page asks for the grade and the key beside each room, so the bedroom wing stands on that list with its thumb turn and its staff key.

The medicines store: D10 behind a shut steel leaf

The medicines store holds the medicines given to residents through the day, and its leaf takes D10, the longest hold LPS 1175 Issue 8.2 names. The doorset is proved as one piece, and its report states ten minutes against the tools the test names.

No glass sits in the medicines store leaf, because a pane would show the corridor what is kept behind it and give a hand a way to the lock, so the leaf runs solid steel from edge to edge. That leaf hangs on hinges proved to BS EN 1935: grade 13 carries 120 kg and grade 14 carries 160 kg, each proved through 200,000 cycles.

TS 007 lets a 1 star cylinder and a 2 star handle join into a 3 star set, so the pair is ordered together. The nurse in charge keeps the key, and the list beside the leaf names who else may open it. The security doors for pharmacies guide shows the same leaf in a pharmacy, and the security doors for GP surgeries guide shows it in a surgery.

Until the nurse in charge turns the key, the medicines store door stays shut

The medicines store door stands shut between rounds, and it opens only when the nurse in charge turns the key, so the medicines wait behind a shut steel door while the centre goes about its day. No other hand in the centre opens that door, and no other key in the centre turns its lock.

One named nurse carries the only key through the whole shift, and it changes hands in person at each handover, never through a drawer or a hook on the wall. The incoming nurse signs for it at the desk while the outgoing nurse stands beside them, so the key stays in sight from one holder to the next. A key left on a desk is a key any passer by can lift.

A reader beside the treatment room door answers only the cards the list names, so the room opens for the therapist whose session it is and stays shut for everyone else. The access control doors guide names the readers and cards that stand guard on a treatment room door.

Point in the day Door state Key holder
Between rounds Shut, lock turned Nurse in charge
At a round Opened, then shut Nurse in charge
At handover Tried with the key Incoming nurse

D10 to LPS 1175 Issue 8 is the grade on the store door, ten minutes under the tools the test names, and FD60 can stand beside it, the fire minutes from EN 1634-1 and the forced entry minutes from LPS 1175 Issue 8 in a single report. The dual certification guide sets out how the two proofs sit together in one report for one door.

One nurse holds the key through the day instead of passing it round the centre

One nurse carries the key through the day, because a key that passes from hand to hand is a key nobody can account for when the store door is found open. One holder means one name beside the store on the list.

The lock on the store door is tried at each handover, with the key worked from the corridor and the door watched as it meets its frame. The security door locks guide sets out the lock a medicines store door needs and the key that opens it from the corridor.

The order is written opening by opening, and each line names the door, its grade and its minutes, so the fitter can match every door to its line before a single door is hung. A door that never made the list can end up guarding the wrong opening. The how to specify security doors guide sets out what each line of the order must carry.

The way out runs through doors that free themselves to a single push, so the first person to reach them gets out whether the power is on or off. The emergency exit doors guide names the doors that must free themselves when the alarm sounds.

The centre order starts at the rooms, and the healthcare doors quote takes the store door with its grade and its key written beside it.

Treatment rooms: C5 where therapy happens behind closed leaves

Treatment rooms hold the therapy that brings residents back toward going home, and the equipment and the notes that therapy needs, so their leaves take C5. A leaf stands shut while a session runs, because the work inside is private, and the therapist opens it only for the resident whose turn it is.

The equipment in a treatment room is light enough to carry, and the notes beside it name the residents and their care, so a leaf left open gives a passer by both. A reader beside the leaf opens only for the cards the list names. The access control doors guide covers the readers and the cards that guard a room like this.

C5 asks for five minutes, the hold a treatment room leaf takes because the room stands empty between sessions and unwatched while the therapists are elsewhere. The closer pulls the leaf home after each person through, so the room is never left standing open by mistake.

Staff office and plant room: C5 on the rooms that keep the centre running

Keys to every other room and records naming each resident sit in the staff office, so its leaf takes C5 and stays locked when the room stands empty. An open office would hand a passer by the keys to the rest of the centre.

The plant room holds the boards and the equipment that keep the lights, the heating and the call system running, and its leaf takes C5 because a stranger through it reaches the boards that feed the whole centre. The plant room door requirements guide covers the leaves of a plant room in full, and the security door locks guide names the lock each leaf must carry.

Both rooms sit at the far end of the corridor, away from the public rooms, and their leaves are checked last on the evening round.

Keys and cards through a long stay: who opens which leaf

Residents stay for weeks, and staff change across shifts, so the keys and the cards must follow the people on duty. The master key systems guide shows how a key plan gives each holder the rooms their own work needs and no other room, while the security door locks guide names the lock each leaf in that plan must carry.

The nurse in charge holds a key that opens every leaf in the clinical corridors, while the therapists hold keys that open only the treatment rooms and the staff office. A resident holds no key to any staff room, and the bedroom key opens only the resident’s own room. A lost card is struck from the list the same day it is reported.

The 10 steps to specify an LPS 1175 door guide takes the order from the first leaf to the last.

The rehabilitation centre order: every leaf, its grade and its lock

The order is one list with a line for every opening, naming the leaf, the grade, the lock and the closer that belong in it. A leaf with no line of its own may be hung in the wrong room, and a C5 leaf on the medicines store holds for five minutes where ten is asked for.

Once a month the centre manager walks the building with the door list and works each leaf in turn. A leaf that drags, a bolt that misses its keep and a closer that leaves a leaf standing open are written against their own doors on the day they are found, and the security door maintenance checklist names what the walk should cover.

The steel door frames guide names how the frame holds the leaf and the lock together, and the keeping an LPS 1175 rating valid guide names what can take a rating away.

Order the leaf, the lock and the closer as one set for each room, and check the set against the room it guards before the leaf is hung.

What grade should a rehabilitation centre entrance door carry?

B3 to LPS 1175 Issue 8.2, which holds for three minutes, because the entrance stands in view of the reception desk.

What grade should a rehabilitation centre medicines store door carry?

D10 to LPS 1175 Issue 8.2, which holds for ten minutes, because the medicines store holds medicines behind a shut leaf.

What grade should a rehabilitation centre treatment room door carry?

C5 to LPS 1175 Issue 8.2, because the treatment room leaf is shut while sessions run, and five minutes is the hold that room asks for.

Can one leaf hold fire and forced entry?

Yes, where the same doorset passed the fire test and the forced entry test, so one report names both the period and the grade for that leaf.

Who checks the rehabilitation centre doors?

The centre manager goes round with the door list once a month and works every leaf, so a fault is found and put right before the leaf is asked to hold.

Specifying security doors for a rehabilitation centre?Send the door list with the grade each room must hold for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.