NPSA Forced Entry and Blast Guidance for Government Sites
NPSA forced entry and blast guidance for government and critical national infrastructure sites, and what a buyer asks a supplier to prove in a spec.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Government and critical national infrastructure buyers ask for NPSA guidance in a spec because it starts from the threat, not the product. This guide covers the forced entry and blast guidance NPSA publishes, and what a buyer asks a supplier to prove.
- TVRA firstThreat, Vulnerability and Risk Assessment before any product
- Three stepsThreats, accepted risk, performance requirement
- VXR and PXRBlast loading categories for vehicle and person borne devices
- Two HVM ratingsImpact rating and VADS delay rating
What the buyer asks for in a spec
A spec for a government or critical national infrastructure site starts with a Threat, Vulnerability and Risk Assessment, known as a TVRA. NPSA guidance says the risk owner should follow a TVRA, and a suitable method is the NPSA Operational Requirement process. The assessment names the threats, the weaknesses of the site and the risk the owner is willing to accept. Only then does the spec name a product.
That order matters because NPSA guidance is written for risk owners and security advisors of government buildings, national infrastructure and other sites likely to face an improvised explosive device threat. The guidance is not a product list. It tells the buyer how to turn a threat into a performance requirement.
The forced entry standards side by side
NPSA publishes a guide to the most widely recognised forced entry standards in the UK, to help security managers choose the right standard for a threat. The standards it covers include BS EN 1627:2021, LPS 1175 Issue 8, LPS 1673 Issue 1, LPS 2081 Issue 1, MFES v2.0, MTAS v1.0, PAS 24:2022 and STS 202 Issue 10. Each defines delay in its own way.
MFES is NPSA’s own manual forced entry standard, with three protection levels: Base, Enhanced and High, matching three attacker types: Novice, Knowledgeable and Expert. A product that passes MFES is listed in the CSE, and our NPSA Catalogue of Security Equipment guide explains what that listing means. MTAS, the marauding terrorist attack standard, measures how long a barrier holds back a marauding attacker, and it gives five sophistication levels: Basic, Low, Moderate, High and Expert. It says nothing about how easily a barrier can be locked and opened again to let people out. Ratings do not translate between standards. Our comparison of LPS 1175 and EN 1627 explains why.
Doors under marauding attack: what the research shows
NPSA research showed steel doorsets can hold back marauding attackers for a significant time. A doorset built from 1.5 mm steel skins over a mineral wool core, held by a single mortice sash lock, can hold a Basic bladed weapon attack for at least 3 minutes, and Low ballistic and Moderate energetic forced entry for at least 0.5 minutes each.
The lock matters more than the leaf. A multi-point surface mounted lock lifts the same doorset to 3 minutes against a Basic attack, 3 minutes against Low ballistic forced entry, 2 minutes against Moderate ballistic forced entry from a handgun or shotgun, and 1 minute against Moderate ballistic forced entry from a rifle, or against High ballistic forced entry. Timber doorsets need a different reading. A 44 mm solid hardwood leaf set in solid rebated hardwood jambs can hold a Basic attack for at least 5 minutes with single-point morticed access control locking.
Windows and glazing under attack
Glazing is vulnerable to manual forced entry, gunshots and explosives, but NPSA research shows it can delay a marauding attacker. A double glazed unit with toughened glass on the attack face and 6.8 mm PVB laminated glass to the rear can deliver at least 30 seconds of resistance to Basic bladed, Low ballistic forced entry and Moderate ballistic forced entry attacks.
For a glazed doorset, the locking matters as much as the glass. NPSA found that at least two locking morticed points offer significantly greater resistance than a single lock, and that lock bolts should engage directly into a keep in the sill or jambs. The laminated glass needs a thickness of at least 10 mm, with a PVB or SGP interlayer. Our blast resistant windows page covers products with a blast rating as well as a forced entry rating.
Blast: protection, mitigation and the rating code
NPSA blast guidance covers blast loading requirements for windows, doors, curtain walling and non-loadbearing walls. It sets out three steps: identify the design threats, define the level of risk accepted by the risk owner, and specify the blast performance requirement. The design threat is expressed as a charge mass in kilograms of TNT equivalent plus a stand-off distance.
Two approaches exist. Blast Protection means the facade resists the blast load with hazards no worse than a selected hazard level. Blast Mitigation means the hazard from glazing and fragments is reduced with practical measures, and the level cannot be quantified. Mitigation measures include laminated glass innermost, anti-shatter film and secondary glazing. Where Protection is adopted, NPSA suggests an internal hazard of C or better and an external hazard of Y or better.
The loading categories are written as a code. VXR categories cover vehicle borne devices, from VXR1 at 100 kg at 34 m to VXR7 at 500 kg at 25 m. PXR categories cover person borne devices, from PXR1 at 3 kg at 9 m to PXR7 at 20 kg at 4 m. Inside, the scale runs A to F. A means the glass stays whole, F means fragments are expected. Outside, the scale runs X to Z, X meaning no hazard and Z meaning high hazard. A requirement is written as the loading category plus the hazard levels, for example VXR5/C/X.
| Loading category | Device and stand-off | Hazard level to aim for |
|---|---|---|
| VXR1 | 100 kg vehicle device at 34 m | C inside, Y outside |
| VXR5 | 100 kg vehicle device at 15 m | C inside, Y outside |
| PXR3 | 3 kg person borne device at 5 m | C inside, Y outside |
| PXR7 | 20 kg person borne device at 4 m | C inside, Y outside |
A blast requirement can be met by a product tested under the BS EN test standards, test reports against other standards examined by a blast specialist, or design calculations approved by independent blast engineers. NPSA notes that the BS EN test standards consider air blast loading but not fragments. For that reason a suitably qualified blast specialist should be involved, and NPSA points to the Register of Security Engineers and Specialists. The blast resistant doors page covers the doorset side of the same requirement.
Stand-off is the cheapest blast measure on any site. Only stand-off enforced by physical barriers or access control gives effective mitigation, so the barrier line and the facade rating must be planned together.
HVM: two ratings, one barrier line
Vehicle borne devices are usually dealt with by hostile vehicle mitigation, and person borne devices by fences, gates and access control. A barrier deployed to counter terrorism should be a rated vehicle security barrier, assessed against a vehicle test standard at an independent test house.
Two ratings matter, and NPSA with the National Counter Terrorism Security Office advises that a barrier should hold both. An impact rating is earned against ISO 22343-1, PAS 68 or IWA 14-1. The VADS side is tested under the NPSA Vehicle Attack Delay Standard, which proves the barrier can hold against repetitive ramming, with 30 seconds of resistance earning a 30 second VADS rating. A rating covers only the barrier exactly as it was tested. Any change needs the installer and the risk owner to review it and agree it. The rating codes are explained on our hostile vehicle mitigation page, and the ISO 22343 guide shows how to work out what a rating code means. The three-body comparison guide explains which of the three bodies a project needs when the brief names more than one.
Putting the spec together
A spec built on NPSA guidance should follow the same order: threat, risk, requirement, evidence. Name the design threats first, with the charge mass and stand-off for each device type. Then name the performance requirement for each element.
Ask for the evidence by name. For a doorset, ask for the CSE listing and the test report behind it. For a window or facade, ask for the blast test report or the design calculations. For a barrier, ask for both ratings and for confirmation that the installed configuration matches the tested one. Record the TVRA process and the decisions made in it. Our data centre physical security guide applies the same thinking zone by zone.
What is a TVRA?
A Threat, Vulnerability and Risk Assessment. It names the threats a site faces and the weaknesses of the site, and it sets the risk the owner will accept.
What does VXR5/C/X mean?
VXR5 is a vehicle borne device of 100 kg at 15 m. C is the internal hazard level, minimal hazard, and X is the external hazard level, no hazard.
Is blast mitigation the same as blast protection?
No. With protection the facade is built to hold the blast load to a chosen hazard level. With mitigation, practical measures cut the hazard, and the level cannot be quantified.
Does a barrier need both an impact rating and a VADS rating?
Both are recommended. The impact rating proves the barrier stops a vehicle at speed, and the VADS rating proves it holds against repetitive ramming.
Can glazing stop fragments from an explosive device?
In most cases, no. Ordinary glazing does not stop fragments, and only very thick glass or a specialist design in a limited area can do so.