ISO 16933 is the standard for blast-resistant glazing. It sets EXV classes for vehicle bombs and SB classes for hand-carried charges, each paired with a hazard rating from A (no break) to F (high hazard). A classification like EXV25(C) tells you the threat tested and the glass response.
- StandardISO 16933 blast glazing
- Threat familiesEXV vehicle bombs, SB satchel charges
- ClassesEXV45 to EXV10, SB1 to SB7
- Hazard scaleA (no break) to F (high hazard)
What ISO 16933 covers
ISO 16933 is the international standard for classifying the blast resistance of glazing. It gives specifiers a shared language: a short code that states the threat a product was tested against and how the glass behaved. Our blast ratings guide places it alongside the related European standards.
The standard divides the threat into two families. EXV classes cover vehicle-borne bombs at a defined stand-off distance. SB classes cover hand-carried satchel charges placed close to the building. Each class is paired with a hazard rating that describes the danger to people behind the glass.
EXV classes and stand-off distance
Every EXV class is built around the same scenario: a 100kg TNT equivalent vehicle bomb at a fixed stand-off distance. The number in the class name is that distance in metres. EXV45 is tested at 45 metres; EXV10 is tested at 10 metres. A shorter stand-off means a far more severe blast, so EXV10 is the most severe class and EXV45 the least.
| Class | Stand-off | Severity |
|---|---|---|
| EXV45 | 45 metres | Least severe |
| EXV33 | 33 metres | Low |
| EXV25 | 25 metres | Medium |
| EXV19 | 19 metres | Medium to high |
| EXV15 | 15 metres | High |
| EXV12 | 12 metres | Very high |
| EXV10 | 10 metres | Most severe |
Start from the stand-off you can actually hold. If hostile vehicle mitigation keeps vehicles 15 metres from the facade, EXV15 is the honest baseline. Government and defence sites often combine a high EXV class on the facade with SB classes at entrances, where stand-off is hardest to control.
SB classes for hand-carried charges
SB classes answer the threat that stand-off cannot reach: a charge carried by hand and placed against or near the building. The family runs from SB1 to SB7, and each step up represents a larger charge, a closer placement, or both. Unlike EXV, the SB threat assumes the attacker is already at the facade.
Entrances, lobbies and ground-floor glazing need this check most, because the public can walk right up to the glass. A facade rated EXV25 can still be the weak point at its doors, which is why blast resistant windows and blast resistant glass at entrances are often specified with an SB class as well.
Hazard ratings A to F
The letter after the class records the glass response in the test, which is what decides the danger to people inside. A means no break: the glazing stays in place. F means high hazard, with dangerous fragment throw. The letters between are graded steps, so each step from B toward F records a more severe response.
| Rating | What it means |
|---|---|
| A | No break. The glazing remains in place. |
| B to E | Graded steps between no break and high hazard. Each letter records a more severe glass response. |
| F | High hazard. Dangerous fragment throw into the room. |
The hazard rating is part of the classification, not an optional extra. Two products can share the same EXV class and still protect people very differently: EXV25(A) and EXV25(F) describe the same threat but very different outcomes for the room behind the glass.
Arena tests and shock tubes
ISO 16933 classifications come from open-air arena tests. A real charge is detonated at the defined stand-off in front of a full-size specimen, and the response of the glazing is recorded. The method measures what a real blast does to a real window build-up, frame and fixings included.
Other standards use different rigs. EN 13123 fires a controlled blast wave down a shock tube, with classes EPR1 to EPR4. EN 13124 uses a range test, with classes EXR1 to EXR5. A shock tube result and an arena result are not interchangeable, so never quote an EPR or EXR class as if it were an ISO 16933 class. See how the blast standards compare.
Test evidence is build-specific. A classification only covers the exact glass make-up, frame and fixings in the tested specimen. Change any of them and the rating no longer applies.
Common specification mistakes
The most frequent mistake is quoting the class without the hazard letter. A schedule that asks for EXV25 has asked for nothing complete: EXV25(A) and EXV25(F) are different products with different outcomes. Always write the full code, letter included, on every schedule and drawing.
The second mistake is assuming one test covers every size. Blast performance changes with pane size, so a classification earned on a small specimen does not automatically cover a full-height atrium panel. Check the tested size range in the report and match your largest pane to it.
The third mistake is mixing standards. An LPS 1175 forced-entry rating says nothing about blast, and a blast classification says nothing about forced entry. Facades that face both threats need both ratings, each from its own test. Our LPS 1175 guide explains the forced-entry side.
EXV and SB on one schedule: naming the test beside the threat
ISO 16933 grades a window by the blast it was tested against, and the two letters on the schedule name two different tests. EXV covers a charge carried in a vehicle at a stand-off distance from the building, and SB covers a hand-carried charge set against the face of the window, so each class names the threat the window was proved to meet.
The EXV classes run from the smallest vehicle charge at the longest stand-off to the largest charge at the shortest distance, and the class on the order should match the vehicle the approach could bring and the distance the site can keep. A class above the threat adds weight, glass and frame without adding safety, so the order should name the threat first and the class second.
The SB classes cover a charge placed by hand, with no stand-off to help the window, so the glass and the frame take the full force at close range. A window proved to an SB class has been tested against a charge at the face, and the test report names the charge weight and the hazard rating the window earned.
The hazard rating runs from A to F and names how far the glass travels into the room, with A holding the pane largely in place and F letting fragments reach well into the room. The rating sits beside the class on the order, because a class without a hazard rating leaves the reader to guess what the room faces. The ratings in full are set out on our blast ratings page, and the windows that carry the rating are covered in our blast resistant windows guide.
Vehicle ratings and blast ratings are separate proofs and must stay apart on the schedule. A window proved to ISO 22343-1 stops a vehicle, and a window proved to ISO 16933 survives a blast, and one test report cannot prove both, so each proof needs its own line and its own report. The vehicle ratings in full are in our ISO 22343 vehicle security barriers guide.
The charge weight and the distance: the two numbers behind the class
Stand-off distance is the number that sets the EXV class, because the further the charge sits from the window, the less force reaches the glass. A site that can keep vehicles further from the building can order a lower class, and a site where vehicles reach the face of the building must order a higher one, so the distance belongs on the order beside the class.
The charge weight is the second number, because a heavier charge at the same distance asks more of the glass and the frame. The person who owns the risk sets both numbers, the charge and the distance, and the order should name them plainly, so the test house and the supplier work from the same threat.
Arena tests and shock tubes are the two ways the test is run, and the report names which one was used. An arena test drives a real charge at the window, and a shock tube drives a pressure wave, so the method belongs on the file beside the class, because a class proved one way is not a class proved the other way. How a schedule should name each proof is set out in our how to specify security doors guide.
| Test | Threat | What sets the class |
|---|---|---|
| EXV | Vehicle charge | Charge weight and stand-off |
| SB | Hand-carried charge | Charge weight at the face |
| Hazard A to F | Glass travel | How far fragments reach |
| Method | Arena or shock tube | How the test was run |
Put the test, the class, the charge and the distance on one schedule line, so whoever reads the file next can see what was tested and what it proved.
How to read a test report summary
A summary should state the class, the hazard rating in brackets, and the specimen build. EXV25(C) means the glazing faced the EXV25 vehicle-bomb threat and earned hazard rating C. SB4(D) means the SB4 satchel-charge threat with hazard rating D.
- Match the class to your threat. The EXV number must reflect a stand-off you can actually hold.
- Check the hazard rating. For occupied rooms, aim for the lowest hazard letter the threat assessment allows.
- Check the specimen. The glass make-up, frame and fixings in the report must match your build.
- Check the source. The report should come from a recognised test house and cover the complete assembly.
If any of those four checks fails, the summary does not prove your window will perform. Blast protection window film is sometimes proposed as a cheaper route, but it cannot carry an EXV or SB classification on its own. When a venue falls under Martyn’s Law, keep the full reports with your compliance file. Browse all ArxBridge guides for related topics.
Is EXV10 better than EXV45?
It is tested against a more severe threat, so the classification is stronger. But the right class is the one that matches your real stand-off. Specifying EXV10 where you hold 40 metres of stand-off spends budget for no extra safety.
Can one product carry both EXV and SB classes?
Yes. Products are often tested against both threat families, and each classification is listed separately with its own hazard rating.
What hazard rating suits an occupied room?
The lowest hazard letter your threat assessment can justify. A means the glass does not break, which is the safest outcome for people behind it.
Does the rating cover the frame as well as the glass?
The classification covers the tested assembly, which includes the frame and fixings used in the test. If your frame differs, the rating does not transfer.
Is an EXR rating the same as an ISO 16933 rating?
No. EXR classes come from the EN 13124 range test and EPR classes from the EN 13123 shock tube. They use different methods and different scales, so they cannot be swapped.
Do I need EXV and SB classes on the same facade?
Often, yes. EXV covers the vehicle-bomb threat at a distance; SB covers a charge placed by hand at the building. Facades with public access at ground level usually need both, each with its own hazard rating.
The frame and the fixings: the parts the class does not name
ISO 16933 grades a window by the blast it was tested against, and the class on the order names the test, not the window. EXV covers a charge carried in a vehicle at a stand-off distance from the building, and SB covers a hand-carried charge set against the face of the window, so each class names the threat the window was proved to hold.
The glass is only one part of the window, and the frame, the fixings and the seal are proved with it as one system. A pane that holds while its frame gives way has held nothing, and a fixing from another system carries no proof on this window. The frame, the fixings and the glass belong on the order beside the class, so the window that is built is the window that was tested.
The hazard rating runs from A to F, and each letter names what the glass did after the blast. A names glass that stayed in the frame, and the later letters name glass that broke and threw fragments further into the room. The letter the order names must match the room behind the window, because a room full of people takes a different letter from a room full of stores.
The stand-off distance sits beside the class on the order, because the distance between the charge and the window is part of the proof. A window proved at one distance proves nothing at a shorter one, so the distance the site can hold is measured before the order is placed, and the class follows the distance the site holds.
After the test: the survey the rating cannot replace
A rating proves one window in a test rig, and the wall the window sits in is proved by the survey. The survey names the wall, the opening and the fixings the test used, because a window set in a wall weaker than the test wall holds no more than the wall beside it. A window ordered without a survey may arrive for an opening it cannot fill, and the survey is finished before the order is placed.
The survey walks the building and measures each opening as it stands, because the opening on the drawing is never the opening on the wall. A reveal out of square, a jamb out of plumb, or a fixing point that has crumbled each changes what the window must do, so the measurements go on the order beside the class, and the window is made to the opening, not to the drawing.
| Part | What to check | What breaks it | When |
|---|---|---|---|
| Glass | Class, hazard letter | Wrong class for the room | Before the order |
| Frame | Proved with the glass | Frame from another system | Before the order |
| Fixings | Named in the test report | Fixing from another system | Before the order |
| Stand-off | Distance held on the site | Shorter distance than tested | Before the order |
| Wall | Survey of the opening | Wall weaker than the test wall | Before the order |
The cost and the specification of a blast window are worked through in the blast resistant windows cost and specification guide, and what the glass itself costs is covered in the fire rated glass cost guide. What window film does and cannot do is set out in the blast window film guide, and the vehicle barriers that hold the stand-off are covered in the ISO 22343 vehicle security barriers guide.