Security Doors West Midlands Explained

Security doors across the West Midlands: industrial estates, logistics yards and business parks, from Birmingham to Coventry and Wolverhampton.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

The West Midlands is not one city with one kind of building. Birmingham holds commercial centres and interchanges, Coventry holds manufacturing and research sites, Wolverhampton holds industrial estates and logistics yards, Dudley and Walsall hold workshops and distribution units, Solihull holds business parks and offices, and West Bromwich holds factories and retail parks. A security door that suits a city centre office does not suit a logistics yard, and a door that suits a yard does not suit a shopfront.

This page covers the region as one market: the premises across the West Midlands, the ratings that suit them, and the way an estate that holds sites in more than one town orders its doors. It is not a page about one city. Our Birmingham page covers the city itself, our security gates Birmingham page covers gates in the city, and our vehicle barriers West Midlands page covers the barriers that guard the region’s entrances.

The sections below work through the region building by building: the industrial and logistics sites that take the most use, the business parks and commercial centres the public meets, the ratings a Midlands buyer should ask for, fire and security on one doorset, access control across a multi-site estate, planning and listed buildings, and the enquiry itself. Our warehouses and logistics sector page covers the buildings that hold the region’s stock, and our warehouse security doors guide covers the doors those buildings need most.

  • LPS 1175Forced entry rating, B3 to D10
  • PAS 24Enhanced security doorset standard
  • FD30 / FD60Fire resistance periods tested to EN 1634-1
  • BS EN 1154Closer power sizes, minimum EN 3 on fire doors

One region, many kinds of premises

A buyer who orders doors for the West Midlands orders for more than one kind of building. An industrial unit in Wolverhampton needs a steel personnel door that takes a forklift, a pallet and a shift of workers every day. A business park office in Solihull needs a glazed entrance that admits staff and visitors and keeps strangers out. A retail park in West Bromwich needs a shutter and a personnel door that close the unit at night and open it in the morning. A distribution yard in Coventry needs a gate, a turnstile lane and a door that guards the stores behind them.

The motorway network shapes where those buildings sit. The M5, the M6 and the M42 run through the region, and the estates beside them hold the logistics yards, the distribution units and the business parks that serve the whole country. A site beside a motorway junction sees more vehicles, more deliveries and more strangers than a site on a quiet street, and its doors should be specified for the traffic it actually sees. Our types of security doors guide sets out the range of doors a region may need, and our how to specify security doors guide covers the discipline of naming the performance in full.

The answer is a door schedule with one line per opening, built site by site. Each line names the building, the position, the fire rating, the security rating where one is needed, the leaf, the frame, the glass, the seals and the hardware as one doorset. A region that orders one door type for every opening will have doors that fail in different ways in different towns.

Industrial and logistics sites: the doors that take the most use

An industrial door opens and closes more often than any other door in the region. A personnel door on a factory in Dudley opens for every shift change, every delivery and every break, and a door on a logistics yard in Coventry opens for every lorry that arrives and leaves. A door that is specified for a quiet office will not last on a factory floor, and a door that will not last will be wedged open within a week.

Steel carries the use. A steel leaf resists the knocks a factory door takes every day: a trolley, a pallet, a boot, a crate. A steel leaf is strong, but strength is not a security rating, and a door that resists a knock may still fail a forced entry test. The rating belongs to the complete tested assembly, not to the leaf alone, so a rated leaf in an untested frame is not a rated doorset. Our fire rated steel doors page covers the steel leaf that carries the hardest use most often.

Loading bays need doors of their own. A high performance roller door opens and closes all day on a busy bay, and a personnel door beside it lets staff in and out without opening the bay. Our loading bay doors guide covers the bay doors in full, and the personnel door beside the bay should be specified at the same time, so the two work as one entrance.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Business parks and commercial centres: the doors the public meets

A business park office in Solihull meets the public every day, and its entrance doors must admit staff and visitors and keep strangers out. A glazed entrance lets reception see who is at the door before it is opened, and a rated screen holds while the door is checked. A screen that is not rated is a screen that fails at the first blow, and the entrance behind it is open. Our fire rated windows guide sets out how glass, frame and beads are tested together.

Commercial centres in Birmingham need doors that take a crowd. Hundreds of people pass through a centre entrance in the minutes before opening, and the doors must take that crowd without slowing it and without failing. The doors must open in the direction of escape, and they must open in one action without a key, because a crowd under pressure cannot queue for a lock. Panic hardware to BS EN 1125 belongs on these doors, with a bar across the leaf covering at least 60 percent of the leaf width.

Opening force matters on a commercial door as much as on any other. A door must open with less than 30 N in the first 30 degrees and less than 22.5 N beyond that, under BS 8300 and Approved Document M, because staff push trolleys, wheelchairs and delivery cages through these doors all day. A closer that is too strong for the leaf makes the door fail the access rules and invites staff to wedge it open. Our fire door closers guide sets out the power sizes in BS EN 1154 and how to read them.

What a rating means for a Midlands buyer

LPS 1175 rates a doorset by the tools and the time it resists. A SR2 rated steel door resists three minutes of attack with tools such as screwdrivers, pliers and hand saws. C5 covers five minutes with crowbars, drills and chisels, and D10 covers ten minutes with sledgehammers, disc cutters and jigsaws. PAS 24 is the enhanced security standard for doorsets, and EN 1627 sets resistance classes RC1 to RC6 for windows, doors and shutters. Secured by Design is a scheme, not a rating, and a door that carries the scheme mark without a test rating has no proven resistance behind it.

The rating should follow the risk, not the postcode. A shopfront in a busy town centre needs a higher rating than a store door in a quiet yard, and a server room door needs a higher rating than a corridor door in the same building. Walk the site from outside and note every door a person can reach, then rate those doors for the attack they could face. Our keeping an LPS 1175 rating valid guide sets out the changes that void a rating and the inspection routine that keeps it alive.

Fire needs its own rating beside the security rating. FD30 and FD60 are fire resistance periods tested to EN 1634-1, and the number is the minutes the doorset holds its rating in the furnace test. A door marked FD30S carries 30 minutes of integrity plus smoke control, tested to BS EN 1634-3. The fire strategy names the period for each opening, and the security requirement names the forced entry rating beside it, so one doorset carries both jobs where the opening needs both.

The rating on the schedule: what each opening asks for

A Midlands estate often spans more than one town. A warehouse in Coventry, an office in Birmingham and a distribution unit in Wolverhampton can sit on one schedule, and each opening still needs its own rating. The rating follows the opening, not the town, so a staffed front entrance suits B3, a rear door that faces a quiet yard suits C5, and a door guarding high value stock suits D10.

Read the rating off the tools and the time. Category B tools, screwdrivers, pliers and hand saws, for three minutes earn B3. Category C tools, crowbars, drills and chisels, for five minutes earn C5. Category D tools, sledgehammers, disc cutters and jigsaws, for ten minutes earn D10. The earlier labels still appear on drawings, so read SR2 as B3, SR3 as C5 and SR4 as D10.

Only the whole tested assembly carries the rating. A leaf tested on its own proves nothing about the frame, the fixings, the glazing or the hardware around it, and a change to any of those parts can break the tested construction. Ask for the test report and the classification naming the exact doorset before the order is placed. The changes that void a rating are set out in our keeping an LPS 1175 rating valid guide.

Where a door serves more than 60 people, BS EN 1125 asks for panic hardware, with the bar spanning at least 60 percent of the leaf width. A door must open with less than 30 N in the first 30 degrees and less than 22.5 N beyond that, under BS 8300 and Approved Document M. A closer that is too strong for the leaf makes the door fail the access rules, so the closer power size belongs on the schedule beside the rating.

Ordering across the region: one schedule, several towns

Build one schedule with one line per opening, naming the building, the town and the position, the fire period and the security rating where one is needed, and the leaf, frame, glass, seals and hardware as one tested doorset. A schedule that names the town beside each opening stops a door meant for one site being fitted on another. Our how to specify security doors guide covers the same discipline column by column.

Distribution buildings need the same discipline as offices. A personnel door on a warehouse opens for every shift change, every delivery and every break, and a door built for a quiet office will not last on a unit floor. Our warehouse security doors guide covers the doors distribution buildings need most, and our Birmingham page covers the region’s largest city.

Fire and security sit on one assembly where a door must do both jobs. A server room door holds fire and keeps an attacker from the equipment inside, and both duties need their own evidence: a fire classification to EN 1634-1 and a forced entry rating to LPS 1175 or PAS 24. FD30 and FD60 are the fire resistance periods tested to EN 1634-1, and the number is the minutes the doorset holds in the furnace test.

Premises Door position Rating What to check
Warehouse unit Personnel door LPS 1175 B3 or C5 Steel leaf, hinges, latch
Distribution unit Loading bay personnel door LPS 1175 B3 or C5 Closer, latch, hold-open release
City office Glazed entrance LPS 1175 where rated Screen rating, reader pace
Stores and plant room Internal doors FD60 Seals, gaps, self-closing

Ask for the evidence to arrive with the doors, and file it on the day they arrive, so the estate holds a record it can use for the whole life of the building.

Fire and security on one doorset for a Midlands site

Many doors in the region must do two jobs: hold fire and resist forced entry. A server room door in a Coventry research site must hold fire and resist an attack on the equipment inside. A plant room door in a Birmingham commercial centre must hold fire and resist a forced entry. The two jobs need two sets of evidence on one assembly: a fire classification to EN 1634-1 and a forced entry rating to LPS 1175 or PAS 24.

The rating must stay valid after handover. A change to the leaf, the frame, the glass, the seals or the hardware can break the tested construction, and a door that has been changed without fresh evidence has no proven rating. Ask for the evidence when a change is proposed, not after it is made. The test report, the classification and the hardware schedule should name the exact doorset. Our dual certification guide works through how fire and security sit on one assembly.

Check the wall the door fixes into. A rated leaf in an unrated wall gives an unrated opening, and a frame fixed into a partition that was never built to hold it will move when the door is used. A warehouse wall, a factory wall and an office partition are three different fixings, and the schedule should name the wall for each opening.

Access control across a multi-site estate

An estate that holds sites in Birmingham, Coventry and Wolverhampton needs one access system, not three. Staff carry cards, visitors use a code or a pass, and contractors use a temporary credential that expires when the work ends. Each method suits a different entrance: a factory needs cards that work at shift change, a business park needs readers that work at walking pace, and a server room needs a check that cannot be lent to another person.

The system should open for the right people and stay closed for everyone else, and it should keep a record of who passed and when. A log that names the credential, the time and the direction of travel is the record the estate needs when a person is found where they should not be. Cards should be cancelled when they are lost, codes should be changed when staff leave, and the list of people who can pass each door should be checked as often as the door itself. Our security turnstiles guide works through readers, fobs and biometrics and how the lane is wired into the access system.

The doors should talk to the same system as the turnstiles, the lifts and the car park, so a person who loses access loses it everywhere at once. Ask for the integration to be named on the order, with the software, the reader type and the record the system keeps. A site that runs a different system in each town is a site that cannot cancel a card everywhere at once.

Planning, listed buildings and conservation areas

The West Midlands holds listed buildings and conservation areas in every town, and a door that suits a new industrial unit may not suit a listed building in a conservation area. A steel leaf in a listed facade needs a finish and a fixing that the conservation officer will accept, and a shutter on a shopfront in a conservation area needs planning consent where the local plan asks for it. Start the planning early, and put the time it takes in the programme from the start.

Check the listing before the order is placed. A listed building carries duties that a new building does not, and a door fitted without the right consent can be ordered out again. The local planning authority names what is needed, and the enquiry should name the listing and the conservation area beside the door schedule. A door that is ordered before the planning is settled is a door that may never be fitted.

Ordering for a West Midlands site: what the enquiry should name

Ordering doors for a West Midlands site is a specification exercise, not a shopping exercise. The enquiry should name the town, the building, the position, the fire rating, the security rating where one is needed, and the leaf, the frame, the glass, the beads, the seals and the hardware as one doorset. The security side needs its own evidence where the door must also resist attack: a rating to LPS 1175 or PAS 24, on the whole doorset, not on the leaf alone.

Finally, order the evidence with the doors. The test report, the classification and the hardware schedule should arrive with the doorset, and the handover pack should name the inspection routine the site will follow. A site that files the evidence on the day the doors arrive has a record it can use for the whole life of the estate. Our security door cost factors guide covers the factors behind a quote in factors-only form, and our fire door inspection checklist gives the checks that catch a failing leaf before it matters.

Premises Door position Rating What to check
Industrial unit Personnel door LPS 1175 where rated Steel leaf, hinges, latch
Logistics yard Stores and plant room doors FD60 Seals, gaps, self-closing
Business park office Glazed entrance LPS 1175 where rated Screen rating, reader pace
Commercial centre Escape and entrance doors FD30 or FD60 Panic hardware, opening force
Retail park Shopfront and rear doors FD30 or FD60 Closer, latch, hold-open release

In the West Midlands, the door that suits a city centre office does not suit a logistics yard, and the estate that orders one door for every opening will have doors that fail in different towns for different reasons.

How is this page different from the Birmingham pages?

The Birmingham pages cover the city itself and single products in it: security gates and security barriers in Birmingham. This page covers the whole West Midlands as one market, with the premises, ratings and ordering routine for commercial and industrial sites from Birmingham to Coventry and Wolverhampton.

Which towns does the West Midlands cover here?

Birmingham, Coventry, Wolverhampton, Dudley, Walsall, Solihull and West Bromwich. The premises range from industrial estates and logistics yards to business parks, retail parks and commercial centres, and the schedule should name the town and the building for each opening.

Do West Midlands industrial doors need a security rating?

They need the rating the risk asks for. A personnel door on a factory that holds stock and equipment needs a forced entry rating to LPS 1175 or PAS 24, on the whole doorset, while a corridor door in the same building may need none. Walk the site from outside and rate the doors a person can reach.

Can one doorset carry a fire rating and a security rating?

Yes, where both sets of evidence cover the same construction. The fire classification comes from a test to EN 1634-1 and the forced entry rating from a test to LPS 1175 or PAS 24, and the two must be proved on the same doorset. A steel leaf is strong, but strength is not a security rating.

What should a West Midlands door enquiry name?

The town, the building, the position, the fire rating, the security rating where one is needed, and the leaf, the frame, the glass, the beads, the seals and the hardware as one doorset. The test report, the classification and the hardware schedule should arrive with the doorset.

Specifying doors for a West Midlands site?Send the door schedule and the fire strategy for a tested doorset quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →