A supermarket fills with shoppers who do not know the building, so fire doors take their period from the room behind them, from floor to plant room.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A supermarket fills with shoppers who have never walked its back corridors, and the fire doors must hold the fire where it starts while those shoppers reach the way out. Each door takes the period the room behind it demands, and the leaf opens for people who have never seen the route.
The period on a supermarket door follows the room behind the leaf, because the sales floor, the stock rooms and the delivery bay ask different things of the doors that guard them. The order carries the period beside each opening, so the leaf that arrives is the leaf the room needs.
The rules for the shared parts of a shop are set out in the fire door regulations retail guide, and the rules for the stores beside the sales floor are set out in the fire door regulations warehouses guide. The supermarket order names every door in the building, with the period and the hardware beside each one.
- FD30 / FD60Fire periods to EN 1634-1
- E / EW / EI 30-120What the letters beside the period mean
- 4 mmThe gap round the leaf
- One listEvery supermarket door named
Sales floor, stock rooms and the delivery bay: one store, three periods
A supermarket is three buildings in one: the floor where the shoppers walk, the stock rooms where the goods wait, and the delivery bay where the lorries unload. The rules follow those parts, because a door between one part and the next must hold the fire where it started while the shoppers reach the way out.
The sales floor takes the doors that let a shopper in and out, and each leaf must open for people with trolleys who have never seen the building before. The stock rooms take the doors that guard the goods, and each leaf must hold fire back where the boxes and crates sit. The route that joins them takes the doors the shoppers pass through, and each leaf takes the period the escape needs.
The supermarket writes its fire strategy first, naming every opening with the door beside it, and the order follows the strategy, so no leaf is ordered without the room it guards behind it.
FD30 and FD60 in a supermarket: the periods each room takes
Each part of a supermarket asks a different period of its doors, because the load behind each leaf is different. The floor holds the shoppers and the goods on the shelves, the stock room holds the goods in boxes and crates, and the delivery bay holds the pallets and the packaging, so the period on each door follows the room, not the leaf.
A fire door is proved under EN 1634-1, and the proof is written as minutes beside letters. The scale runs from 30 minutes to 120, and the letters name what stayed back: flames on their own, flames with some of the heat, or flames with the heat as well.
The longer the period, the heavier the leaf, and the deeper the frame that carries it, so the figure on the quotation climbs with the weight. An opening that needs 60 minutes must never take a leaf proved for 30, because the shorter leaf gives way first.
The sales floor: trolleys, tills and the doors between them
The sales floor is open plan, and the doors on it must hold their proof while letting shoppers pass with trolleys all day. A glazed leaf lets a shopper see the aisle beyond it without opening the leaf, and the pane takes the same proof as the leaf, because the leaf and the glass are proved as one doorset.
The goods on the shelves carry a fire load of their own, and the doors between the floor and the stock room must hold the fire where it starts. A leaf between the floor and the stock room takes the period the stock room demands, because the fire that starts among the shelves must stay among the shelves while the shoppers move out.
The fire rated windows guide covers the windows that share the same wall, and what the glass itself costs is worked through in the fire rated glass cost guide.
Stock rooms and the delivery bay: the doors behind the shelves
The stock room takes the heaviest fire load in the supermarket, because the goods sit there in boxes and crates all day. A stock room leaf takes FD60, and the period follows the fire load, not the size of the store.
The delivery bay takes the same care, because the pallets and the packaging behind its doors burn fast once the fire reaches them. A delivery bay leaf takes the period the load behind it demands, and the seals round it must hold as long as the leaf, because a seal that has come away lets the smoke reach the corridor first. The gap round the leaf is kept to 4 mm, and the seal is checked with the leaf shut.
The delivery bay takes doors that stand open through the day, so the lorries can unload without stopping at every leaf. A leaf that must stand open takes a hold-open device proved to BS EN 1155, so the leaf shuts on its own the moment the alarm sounds. A leaf wedged open with a pallet holds nothing back when the fire comes, and the wedge belongs in the store, not under the leaf.
The cash office and the plant room: the doors that guard the takings and the services
The cash office holds the takings, and the leaf that guards it takes the period the room beside it takes. A cash office leaf takes FD60 where the office sits beside the stock room, because the fire that starts among the goods must not reach the takings and the records.
The plant room takes the same care, because the refrigeration plant and the electrical boards sit behind its doors all day. A plant room leaf takes FD60, and the seals round it are checked with the leaf shut.
Some supermarket leaves carry a forced entry proof beside the fire proof, because the cash office and the stock room need both. The category follows the value behind the leaf: B3 holds three minutes, C5 holds five and D10 holds ten under Issue 8.2, dated September 2024. How the two ratings sit beside each other is covered in the LPS 1175 vs PAS 24 guide, and what can break a rating after a door is fitted is named in the keeping an LPS 1175 rating valid guide. The fire and security doors dual certification guide covers how one doorset carries both proofs.
Escape routes through a supermarket: the way out for shoppers
The shoppers in a supermarket follow the route the building gives them, and the way out must be clear when the alarm sounds. Each door on the route opens with one push, whether the power is there or not.
Route doors carry a smoke proof under BS EN 1634-3: Sa for smoke at room temperature, S200 for smoke at 200 degrees. A seal holds only where it meets the frame all round, and smoke reaches the route before the flames do. The smoke control doors guide covers how the doors hold smoke back while people move past them.
Every leaf on one route carries the same period, because the shortest proof on the route sets how long the whole route holds. A leaf proved shorter than the leaves beside it fails first, so no leaf on the route takes less than the period the route needs. The warehouse security doors guide covers the doors that guard a warehouse, and a supermarket takes the same care with its stock rooms as a warehouse takes with its own.
| Position | Door | Period | What to check |
|---|---|---|---|
| Sales floor | Glazed leaf | FD30 | Leaf, glass, closer |
| Stock room | Steel leaf | FD60 | Leaf, lock, seals |
| Delivery bay | Steel leaf | FD60 | Leaf, closer, seals |
| Cash office | Steel leaf | FD60 | Leaf, lock, seals |
| Public route | Fire leaf | FD30 | Leaf, bar, closer |
| Plant room | Fire leaf | FD60 | Leaf, seals, gap |
The closer, the seal and the gap: what holds the period
The closer on a supermarket leaf works harder than the closer on any other door, because shoppers pass through it all day with trolleys. Under BS EN 1154 a fire door closer takes at least EN 3, and the check is to open the leaf and watch it come home on its own. A closer that has lost its pull leaves the leaf standing open after the shopper has passed, and a leaf left standing open holds nothing back.
A 4 mm gap is left beside the leaf, so it swings free and the seal meets the frame all round when the leaf shuts. When the heat reaches near 200 to 250 degrees the intumescent seal swells and closes the gap the leaf leaves, unless paint laid over the seal holds it down. A seal that has slipped out of its groove goes against its door on the day it is found, with the part and the date beside it.
The hinges carry the leaf through every opening of the day, and a hinge that works loose lets the leaf sink a little month by month until it drags and the gap at the top lets smoke through. What the lock the key turns must do is named in the fire door hardware guide, and sizes and fitting for closers are worked through in the fire door closers guide.
The supermarket order: every door on one list
One list carries the whole supermarket order, with a line for every door and the leaf, the period, the lock and the closer beside each one, so the door that arrives is the door each room needs. A list that names one leaf for the whole store leaves the fitter guessing which room takes which period, and a leaf fitted to the wrong room guards the wrong thing.
Each figure on the quotation is checked against the list, sitting beside the door it belongs to, because a figure missed off the quotation still has to be paid, and a part added later costs more than the same part ordered with the building. The columns the list needs are set out in the how to specify security doors guide, and what each step up the scale adds to the price is worked through in the security door cost factors guide.
Before the shutters lift each week the store tries its leaves in turn, starting at the entrance and finishing at the delivery bay. A leaf that drags, a seal that has slipped from its groove, or a closer that has lost its pull goes in the record against its door on the day it is found, and the repair is booked while the fault is still small. The record stays with the store file, and what the visit should cover is set out in the fire door inspection checklist.
A supermarket leaf holds only as long as the shelves behind it and the route beside it, so the period, the release and the closer must all sit on the same list.
What period should a supermarket door carry?
FD30 or FD60 under EN 1634-1, and the letters beside the minutes name what the doorset held back. The room behind the leaf decides which period the door takes.
Can one leaf hold fire and forced entry?
Yes, where one leaf, frame and seals were proved for fire and for forced entry together, so a single report holds both proofs.
Do supermarket doors need panic hardware?
Yes, the leaf on the way out takes a panic bar proved to BS EN 1125, across at least 60 percent of the leaf, so one push throws the latch for the shoppers behind it.
What grade should a stock room door carry?
The grade follows the room: B3, C5 or D10 to LPS 1175, with the stock room taking a higher category than the sales floor.
Who checks the supermarket doors?
The store manager walks the round that covers every door, and each visit is written into the record the store keeps.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.