A PAS 68 bollard rating states the vehicle stopped, the speed, the angle and how far the vehicle travelled past the line. Read the full code before comparing products, because a bollard tested at one speed and depth does not prove the same result at another.
- V/7500[N3]/80/90:0/0Example PAS 68 rating, decoded below
- 48, 64 and 80 km/hCommon vehicle impact test speeds
- 1,200 mm maximumClear gap between bollards, measured at 600 mm high
- ISO 22343-1:2023Current international standard, superseding PAS 68 and IWA 14-1
What a PAS 68 rating actually says
A PAS 68 rating is a short code that records one crash test. Each part answers a different question, and dropping any part leaves the rating meaningless. Take the example V/7500[N3]/80/90:0/0 and read it from left to right.
V means the test used a real vehicle. The number 7500 is the vehicle mass in kilograms, and [N3] is the vehicle category. The number 80 is the impact speed in kilometres per hour, and 90 is the impact angle in degrees, meaning the vehicle struck head on. After the colon, 0 is the penetration distance in metres, meaning the load carrying part did not travel past the rear face of the barrier. The final 0 is the debris dispersion distance in metres, meaning major debris weighing 25 kg or more did not travel past the barrier line.
Penetration decides whether a line works on a real site. A line with 7 metres of penetration protects nothing within 7 metres behind it, however strong the bollards look, so the stand-off distance between the line and the asset must be greater than the penetration figure. A rating also says nothing about a different vehicle, speed or angle: a bollard rated for a 1,500 kg car at 48 km/h has not been shown to stop a 7,500 kg truck at 80 km/h.
PAS 68, IWA 14-1 and ISO 22343-1:2023
PAS 68 is the UK specification for vehicle security barriers. IWA 14-1 is the international agreement that followed it, using the same test method and a similar rating format, which made ratings easier to compare across borders. ISO 22343-1:2023 is the current international standard, and it supersedes both PAS 68 and IWA 14-1.
For a new specification, name ISO 22343-1:2023 and accept a PAS 68 or IWA 14-1 rating only where the project brief still calls for it. The three standards test the same kinds of vehicle: a 1,500 kg car, a 2,500 kg 4×4, a 3,500 kg van, a 7,200 or 7,500 kg truck, and a 30,000 kg truck, at common speeds of 48, 64 and 80 km/h. Do not mix rating formats in one comparison: a comparison only works when vehicle mass, speed, angle and penetration are stated in full for each product. The HVM standards guide compares the three documents, and the vehicle impact ratings page sets out what a rating must state.
How to read the rating string on a bollard order
ISO 22343-1:2023 is the current international standard for vehicle security barriers, and it supersedes both PAS 68 and IWA 14-1. For a new specification, name ISO 22343-1:2023 and accept a PAS 68 or IWA 14-1 rating only where the project brief still calls for it.
A rating is a short code that records one crash test. Each part answers a different question, and dropping any part leaves the rating meaningless. Take the example V/7500[N3]/80/90:0/0 and read it from left to right. V means the test used a real vehicle. The number 7500 is the mass of the vehicle in kilograms, and [N3] is the vehicle category. The number 80 is the impact speed in kilometres per hour, and 90 is the impact angle in degrees, meaning the vehicle struck head on. After the colon, 0 is the penetration distance in metres, meaning the load carrying part did not travel past the rear face of the barrier. The final 0 is the debris dispersion distance in metres, meaning major debris weighing 25 kg or more did not travel past the barrier line.
The test vehicles run from a 1,500 kg car to a 30,000 kg truck, and the vehicle on the order should match the threat the site faces. A 1,500 kg car at 48 km per hour suits urban footways and retail frontages, a 2,500 kg 4×4 at 64 km per hour suits city centres and venue approaches, and a 7,500 kg truck at 80 km per hour suits government sites and critical infrastructure. Start from the threat vehicle and the speed it could reach on the approach, and ask for the test report, not the rating string alone. Our guide to ISO 22343 vehicle security barriers explains how to read the rating in full, and our vehicle impact ratings page sets out how the three standards sit together.
What to ask for on the order before you sign
The rating belongs to the complete tested installation, not to the bollard alone. The foundations and the ground are part of the tested bollard, so a rated bollard in an untested foundation is not a rated line. Ask for the certificate naming the exact bollard, its foundation detail and its configuration. A certificate for a different model does not cover the order. Our guide to PAS 68 bollard foundations sets out the deep and shallow choice in full.
The spacing belongs on the order too. ProtectUK guidance sets 1,200 mm as the maximum clear gap between barriers in a line and 500 mm as the minimum height, so check the whole frontage, not one bollard. A gap wider than 1,200 mm beside the last bollard is a gap a vehicle can use. ISO 22343-1 Part 2 covers selection, installation and use, and Part 1 proves what a barrier stopped on the test track.
The order should name the bollard, the foundation, the spacing, the finish and the service routine, and the evidence should arrive with the bollards. A bollard described as heavy duty without a certificate has no proven rating at all. Our guide to choosing HVM bollards compares the bollard side of the same decision, and our hostile vehicle mitigation page covers the whole line of defence the bollards stand in.
| Part of the rating | What it records | Example V/7500[N3]/80/90:0/0 |
|---|---|---|
| V | Real vehicle test | V |
| 7500 | Vehicle mass in kilograms | 7,500 kg truck |
| [N3] | Vehicle category | N3 |
| 80 | Impact speed in km per hour | 80 km per hour |
| 90 | Impact angle in degrees | 90, head on |
| 0 after the colon | Penetration distance in metres | 0 metres |
| Final 0 | Debris dispersion distance in metres | 0 metres |
Keep the evidence with the bollards. The test report, the foundation drawing and the service schedule should travel with the installation, and a line that can prove its rating, its foundations and its spacing is a line the site can rely on.
Fixed, removable, automatic and shallow-mount bollards
Fixed bollards are the simplest type: a steel post set in a foundation, always in place, with no moving parts. They suit a line that never needs to open, such as a building front or a pedestrian zone. Their weakness is access: emergency vehicles, deliveries and maintenance vehicles cannot pass a fixed line without a separate gate.
Removable bollards lift out of a ground socket, so a line can open for occasional access, such as a service yard. Their weakness is people: a removed bollard must be stored, replaced and locked, and a line with a missing bollard has a gap a vehicle can use. Automatic bollards rise and fall on command, so they suit entrances used every day, such as a staff car park. They need power, controls, safety edges and a maintenance plan, and you must ask whether they fail safe or fail secure when the power fails.
Shallow-mount bollards need less depth below ground, so they suit sites where deep digging is impossible, such as a basement roof or ground full of services. Their foundation is still part of the tested system, and a shallow foundation that was not tested with the bollard carries no rating.
| Type | Access | Needs | Best for |
|---|---|---|---|
| Fixed | Never opens | Foundation only | Building fronts, pedestrian zones |
| Removable | Lift out by hand | Sockets, storage, locking | Occasional service access |
| Automatic | Rises on command | Power, controls, safety edges | Daily staff and delivery entrances |
| Shallow-mount | Fixed, shallow depth | Tested shallow foundation | Basement roofs, service heavy ground |
Foundations: deep versus shallow, and why the rating covers the installation
A bollard rating belongs to the tested installation, not to the steel post alone. The test installs the bollard in a specified foundation, in specified ground, and measures what happens when the vehicle strikes. Change the foundation, the depth or the ground, and the test no longer describes the installation.
Deep foundations spread the impact load into a large block of concrete below ground. They suit open ground where digging is straightforward. Shallow foundations spread the load across a wider area near the surface, using a frame or a raft, and they suit ground where depth is limited. Both work when tested, and neither works on the strength of the post alone.
Ask for the foundation drawing. A bollard quote without a foundation detail, a depth and a concrete specification is a quote for a post, not for a rated line. Ask for all three in writing.
Buy the tested system, foundation included, and install it as tested. If the site ground differs from the test ground, for example made ground, a high water table or a void below, raise it before ordering, because the foundation design may need to change. The guide to choosing HVM bollards explains how to match the foundation to the site.
Spacing, lines and pedestrian and disabled access
A bollard line fails at its widest gap. Government hostile vehicle mitigation guidance states that the maximum clear distance between adjacent vehicle security barriers must be no greater than 1,200 mm, measured between structural elements at a height of 600 mm above ground level. That figure blocks a vehicle while still letting pedestrians, wheelchairs and pushchairs pass. The same guidance gives 500 mm as the minimum height for a vertical fixed structure, and notes that 900 mm or more makes the measure more conspicuous and assists people with impaired vision.
Spacing must be measured the same way on site as in the guidance: clear distance between bollards at 600 mm high, not centre to centre, and not at ground level where a tapered bollard is narrower. Gaps at gates, drains, corners and street furniture must follow the same rule, because a vehicle uses the widest gap, not the average gap. Access for disabled people is part of the same design: a line that blocks wheelchairs fails the site even if it stops vehicles, so the line must include a managed crossing point that meets access needs without letting a vehicle through.
Utilities, ground conditions and the survey before digging
Digging a bollard foundation without a utilities survey is the most common cause of delay on a bollard project. Power cables, gas pipes, water mains, drainage and telecoms ducts all sit at foundation depth, and striking one stops the work and can be dangerous. A survey should map every service along the line before any design is fixed, and the line should move around services where possible.
Ground conditions decide the foundation type. Made ground, soft clay, a high water table, tree roots and existing slabs all change how a foundation behaves, and a foundation designed for firm ground may fail in soft ground. A trial pit or a borehole along the line answers the question early, when moving the line is still cheap. Installers should confirm the ground conditions and the foundation design in writing before the first dig, and allow for drainage falls, surface levels for automatic bollards, and a safe pedestrian route during the work.
What drives cost, without figures
Foundation depth is the largest cost driver on most bollard lines. A deep foundation needs more excavation, more concrete and more time than a shallow one, and ground that needs dewatering, shoring or service diversions adds further work. The number of units matters too: a long line needs more foundations, more steel and more setting out than a short one.
Bollard type changes the cost in a different way. Fixed bollards cost mainly in steel and foundations. Removable bollards add sockets, locking and storage. Automatic bollards add power supplies, controls, safety equipment, commissioning and a maintenance plan, and those running costs continue for the life of the line. Other drivers are easy to miss in a first quote: ground investigation, service surveys and diversions, traffic management, reinstatement of paving and landscaping, access control integration, and the test evidence itself. A quote that omits any of these is not cheaper, it is incomplete. Compare quotes on the same scope: same rating, same foundation, same number of units, same controls and same reinstatement. The security bollards page covers the product range, the hostile vehicle mitigation page covers the wider measures, and security gates and sliding vehicle gates cover vehicle entrances that open. The installation page covers fitting, the maintenance page covers upkeep, and the guides hub holds the full library.
What does V/7500[N3]/80/90:0/0 mean?
It means a vehicle of 7,500 kg, category N3, struck the barrier head on at 80 km/h, and the load carrying part travelled 0 metres past the rear face of the barrier, with major debris travelling 0 metres. V means the test used a real vehicle, and 90 is the impact angle in degrees.
Is a PAS 68 rating still valid now that ISO 22343-1:2023 exists?
Yes, as a record of a test already carried out. For a new specification, name ISO 22343-1:2023, which supersedes PAS 68 and IWA 14-1, and accept a PAS 68 or IWA 14-1 rating only where the project brief still calls for it.
How far apart should bollards be?
Government hostile vehicle mitigation guidance states the maximum clear distance between adjacent barriers must be no greater than 1,200 mm, measured between structural elements at 600 mm above ground level. Measure the clear gap at that height, not centre to centre, and apply the same limit at gates, drains and corners.
Can I fit a rated bollard into my existing foundation?
Only if that foundation matches the tested foundation for that bollard. A rating belongs to the tested installation, foundation included, so a tested bollard in an untested foundation has no rating. Ask for the foundation drawing and check it against the site.
What should I ask for in a bollard quote?
The full rating code, the foundation drawing and depth, the number of units, the bollard type, the controls for any automatic units, the ground investigation and service survey scope, and the reinstatement included. Compare quotes on the same scope, and ask for the test evidence to be supplied with the installation.
What a PAS 68 rating does not prove
A PAS 68 rating proves one thing: the tested bollard, foundation and ground together stopped the test vehicle within the stated penetration. It proves nothing else. Treat the certificate as a narrow statement, and ask what it leaves out before the order is placed.
It does not prove the bollard suits every vehicle. The rating names a test vehicle, a speed and an angle, and a vehicle heavier or faster than the test vehicle is outside the rating. A line rated for a car is not rated for a truck, and a rating that names one vehicle does not cover the next one up. Match the rating to the threat vehicle, not to the bollard that looks strongest.
It does not prove the foundation. The rating covers bollard, foundation and ground as one installation, and a foundation built differently from the tested one is a different installation. Shallow foundations need a wider raft where depth is limited, and a foundation poured over unmapped services is a foundation that may fail at the first strike. Our bollard foundations guide sets out how the foundation spreads the load.
It does not prove the line. One bollard stops one vehicle at one point. A line with a gap wider than 1,200 mm lets a vehicle through, and a line that stops at a kerb or a planter leaves the entrance open. ProtectUK guidance sets 1,200 mm as the maximum clear gap between HVM elements and 500 mm as the minimum height, so check the whole line, not one post.
It does not prove the bollard will still stop a vehicle after years of use. A fixed bollard that has been hit, a removable bollard with a worn socket, an automatic bollard with a failing drive, all lose performance silently. Check the line at every inspection and keep the test report with the building records. A line that has never been checked is a line nobody can speak for.
Mistakes that weaken a bollard line
Most bollard lines fail in small ways. Each mistake below has the same result: a line that looks complete and stops nothing.
| Mistake | Why it fails | What to do instead |
|---|---|---|
| Ordering the bollard without the foundation | The rating covers the installation, not the post alone. | Order bollard, foundation and ground works as one tested installation. |
| Spacing wider than 1,200 mm | A vehicle passes through the gap. | Keep clear gaps at or below 1,200 mm. |
| No survey before digging | Services at foundation depth stop the work or break the foundation. | Map utilities and ground conditions first. |
| Removable bollards left unsecured | A socket with no bollard in it is an open entrance. | Lock every removable bollard and check the sockets. |
| No record of the rating | Nobody can check the line against what was tested. | File the test report with the building records. |
Keep the evidence with the line. The test report, the rating and the foundation design should travel with the installation, so the next inspection can check what was fitted against what was tested. For choosing between fixed, removable and automatic types, see our choosing HVM bollards guide.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.