Fire Door Rules for Cricket Clubs
Members move between the pavilion, the bar and the changing rooms, so each door takes the fire period its room demands, FD30 at the front and FD60 behind it.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Members at a cricket club move between the pavilion, the bar and the changing rooms, so each door takes the fire period its room demands. The pavilion entrance, the bar, the kit store and the changing rooms take FD30, and the kitchen, the back office and the plant room take FD60, because the rooms behind the front hold the heat, the papers and the services, and those rooms ask for a longer hold than the route out.
The minutes after FD come from EN 1634-1, which runs from 30 to 120, and the letter beside the number names what the leaf held back in its test. E means flame on its own was held, EW means flame with some of the heat was held, and EI means flame with the heat as well was held, so the number counts minutes and the letter names what stayed back.
A cricket club follows the same fire rules as any other building where people move between rooms they know well and rooms they have never used, and the period on each leaf follows what sits behind it and how fast the people behind it can move. The fire door regulations leisure centres guide covers the fire rules for a building where a match and a meal give way to sports halls and pools, and the fire door regulations stadiums guide covers the rooms of a ground where a crowd watches from a stand.
- FD30 / FD60Fire periods to EN 1634-1
- KitchenWhere FD60 holds the heat
- Sa / S200Smoke ratings to BS EN 1634-3
- One listEvery pavilion door named
Seven rooms in a cricket pavilion: the period each leaf takes
Seven rooms make up the pavilion, and the period follows what each room holds. Members come in through the pavilion entrance, drink in the bar, fetch kit from the kit store and change in the changing rooms.
FD60 sits on the kitchen, the back office and the plant room, because the heat, the papers and the services behind those leaves need sixty minutes before flame reaches them. FD30 sits on the pavilion entrance, the bar, the kit store and the changing rooms, because the people on that route reach the outfield in far less than thirty minutes.
The order gives every opening a line of its own, naming the leaf and the period beside it, so no leaf is hung on guesswork. The table below puts the seven rooms with the period each one takes and the grade beside the period, so the fitter matches each leaf to its line as it is hung.
| Room | Period | Grade | What to check |
|---|---|---|---|
| Pavilion entrance | FD30 | B3 | Leaf, glass, closer |
| Bar | FD30 | B3 | Leaf, glass, closer |
| Kit store | FD30 | B3 | Leaf, lock, closer |
| Changing rooms | FD30 | B3 | Leaf, lock, closer |
| Kitchen | FD60 | C5 | Leaf, lock, seals |
| Back office | FD60 | C5 | Leaf, lock, seals |
| Plant room | FD60 | C5 | Leaf, lock, seals |
What FD30 and FD60 hold back in a cricket pavilion
A period counts the minutes a doorset earned in its test, where the doorset is the leaf, the frame, the fixings and the lock proved as one. The order writes the period beside the leaf, and what the report behind a period must hold is named in the fire door certification guide.
One doorset in the pavilion can carry the fire proof and the forced entry proof in a single report. EN 1634-1 gives the fire minutes, and LPS 1175 Issue 8.2 of September 2024 gives the forced entry grade in B3 and C5, while the fire and security doors dual certification guide shows the pair proved on the same leaf.
Members who have never used the pavilion need the route to stay clear while the bar empties, so a swollen leaf or a dragging leaf is put right at once.
FD60 in the kitchen, back office and plant room
Behind the kitchen leaf sit the cookers and the gas that feed teas at the interval, so the leaf takes FD60 and stays shut while the cookers are hot and the volunteers are serving.
Behind the plant room leaf sit the boards and the equipment that keep the water hot and the lights on, so the leaf takes FD60 because the boards behind it feed the whole pavilion. The plant room fire doors guide names what a leaf on that room must hold, and the leaf stays shut because an open plant room leaf would let flame reach the boards in seconds.
The back office leaf takes FD60 as well, because the membership lists and the fixture lists behind it cannot be remade once flame reaches them. Each leaf is shut as the last person leaves the room, because a leaf left open holds back no flame.
Pavilion entrance, bar and changing rooms: FD30 on the way out
The pavilion entrance leaf, the bar leaf and the changing room leaf all take FD30, because members and visitors pass through them on the way out to the car park. Thirty minutes is more than the people on that route need to reach the outfield.
Where the way out serves more than 60 people, the leaves on it carry a push bar proved to BS EN 1125, and the bar runs across no less than 60 percent of the leaf width. One push from a member with a crowd behind them throws the leaf open, and the bar works with the supply on or off. What the bar must do when a crowd pushes against the leaf is named in the panic hardware guide, and the leaves on the way out are covered in the emergency exit doors guide.
The alarm may sound while visitors who have never used the pavilion are still in the bar, so the route to the car park is signed at every turn and nothing stands on it. A leaf on the way out must still open to a push from a member carrying a kit bag, and BS 8300 with Approved Document M puts the push below 30 N through the first 30 degrees of swing and below 22.5 N beyond that. The fire door regulations restaurants guide covers the rooms of a building where food is cooked beside a bar.
Kit store: FD30 beside bats, pads and club kit
The kit store holds bats, pads, gloves and helmets on shelves beside the changing rooms, so its leaf takes FD30 to hold the room clear while the kit inside is carried out. Thirty minutes is more than the players need to fetch the kit and reach the outfield.
The kit store leaf is shut whenever no one is fetching kit, because an open leaf lets flame reach the shelves in seconds. The fire door regulations community centres guide covers the rooms of a hall where stores sit behind shut leaves, and the same rule holds in the pavilion.
The kit store leaf carries FD30 beside the grade the room demands, and its hardware was proved with the leaf, so no fitting fitted later takes the period off it.
Smoke in the pavilion: Sa and S200 beside the period
Members leaving the bar meet smoke before flame, so the leaves on the way out carry a smoke rating beside their fire period. The two smoke ratings come from BS EN 1634-3, Sa for smoke at room temperature and S200 for smoke at 200 degrees.
Where a leaf must stand open while the pavilion is busy, a device proved to BS EN 1155 holds it, and the device lets the leaf go by itself the moment the alarm sounds. The fire compartmentation guide names how the leaves hold the line between one part of the pavilion and the next, and a wedge under a leaf is never the device that holds it, because a wedged leaf holds no period at all.
Closers, seals and gaps: what the pavilion period rests on
Three things carry the hour on an FD60 leaf, the closer pulling it shut, the seals meeting the frame and the gaps staying narrow, because flame slips through a leaf left ajar in seconds and through a wide gap soon after. The closer on the leaf holds a proof to BS EN 1154, where EN 1 is the smallest power size the standard names and EN 3 is the lowest size a fire door takes.
Once the temperature at the frame passes 200 degrees and before it reaches 250, the seal swells across the gap and blocks flame and hot gas from slipping past the leaf. A gauge held against the gap round a hung leaf on the monthly walk shows at once when the 4 mm gap has opened wider. How the seal is fitted is covered in the intumescent seals guide, what the closer must do in the fire door closers guide, and how the gaps are measured in the fire door gaps guide.
A fire leaf hangs on hinges proved to BS EN 1935, with grade 13 proved through 200,000 cycles under a leaf of 120 kg and grade 14 proved through the same cycles under a leaf of 160 kg, so the hinge suits the weight of the leaf it carries. The fire door signage guide names what each sign on a fire door must say, and the fittings proved with the leaf are named in the fire door hardware guide.
The cricket club fire door order: every leaf, its period and its proof
The whole fire door order sits on one list, with a line for every opening that names the leaf, the period, the lock and the closer beside it. One leaf named for the whole pavilion leaves the fitter to guess.
Each leaf on the order is read through before the order is signed, because a closer that arrives after the doorset holds the job up and a leaf with no line beside it cannot be checked on arrival.
The club secretary takes the door list round the pavilion each month and works each leaf in turn, and a dragging leaf, a closer that leaves the leaf standing open and a seal painted over each go beside their own door on the list the day they are found, so the fault is put right before the leaf must hold. What to look for on each leaf is named in the fire door inspection checklist, and the work that keeps the leaves holding is covered in the fire door maintenance guide.
The period on a cricket pavilion leaf follows the room behind it, so the FD60 and FD30 leaves sit on the same list as the grade and the lock for each leaf.
What period should a cricket club kitchen door carry?
FD60 to EN 1634-1, because the cookers sit behind the kitchen leaf, and sixty minutes is the hold that room asks for.
What period should a changing room door carry?
FD30 to EN 1634-1, because the changing room leaf holds the room clear while players fetch their kit, and half an hour is the hold that room demands.
Can one leaf hold fire and forced entry?
Yes, where the same leaf was proved in the fire test and in the forced entry test, so the period and the grade stand in one report together.
Do cricket pavilion fire doors need a smoke rating?
Yes, Sa or S200 to BS EN 1634-3 sits beside the period on the leaves of the way out, because smoke reaches people leaving the pavilion before flame does.
What happens when a fire door will not shut?
A leaf that will not shut goes beside its own door on the list the day the fault is found, and the pavilion does not wait for the next look round before the leaf is put right.