Details never shared

A test report and a certificate are two different papers, and a buyer who treats them as one will accept proof that does not cover the door on order. The report records one test; the certificate stands behind the product as it is made.

  • Test reportOne test, one specimen
  • CertificateThe scheme behind the product
  • PAS 24Current edition 2022+A1:2024
  • Police Preferred SpecificationTested and certified, not tested only

The report is not the certificate

A manufacturer can submit a product for testing to a recognised security standard at a test laboratory, often accredited by the United Kingdom Accreditation Service, and pass. That pass is recorded in a test report. The report names the standard tested, the product as built, and the result it earned, and it belongs to the specimen that was tested on that day.

Secured by Design draws the line plainly: passing a test does not ensure that the product tested is the same as the mainstream manufactured item, nor that it is representative of the range of products. A report proves one specimen passed once. It says nothing about the next unit off the line.

Certification is the step beyond the report. The Secured by Design page on Police Preferred Specification explains the difference, and the LPS 1175 vs PAS 24 guide is the place to compare the two standards, with the evidence a buyer most often meets.

What the report names

Read the report for five things. First, the standard title and the edition tested: the edition in force is PAS 24:2022+A1:2024, which supersedes PAS 24:2022. Second, the product as built: leaf, frame, size, glazing and hardware, exactly as the specimen stood in the laboratory. Third, the laboratory that ran the test, and whether it holds accreditation. Fourth, the result: a pass against the standard named. Fifth, the date, so the edition and the product can be matched to the order.

A report that names only the rating, and not the product it belongs to, leaves the buyer with nothing to check against the order. A report for a fixed window does not cover an opening sash, and a report for one locking arrangement does not cover another. The specimen description is the part that ties the paper to the product, and a short description that hides the hardware is a warning sign.

Keep the report with the certificate and the schedule, and match all three to the order before it is placed. The PAS 24 guide explains what the standard tests and how Approved Document Q uses it.

Document What it proves What it does not prove
Test report One specimen passed one test The next unit, or the range
Certificate The product range meets the standard Installation on site
SBD listing Tested and certified to PPS Fire performance, unless listed
Brochure claim Nothing on its own Any test at all
Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

What the certificate adds

Certification gives quality assurance, and it starts where the report stops. When a manufacturer seeks Secured by Design status, it submits the product range for certification. A number of products, representing the whole range, are selected for testing, and if they all pass they can be accepted into the certification scheme.

The certification authority then visits the production facility to ensure that the products tested are representative of the products supplied to the end user. Regular visits follow, to ensure that quality standards are met and that components have not been altered without informing the authority. During the year the authority removes a small number of products for re-testing, and should any part of the security standard change, the manufacturer is expected to upgrade its products to retain certification.

Independent certification therefore involves initial testing, regular re-tests and inspections of the production facility, so the product stays as it was proved. A certificate without that follow-up is a photograph, not a promise. For the LPS 1175 side, the same check runs on the live Red Book Live listing, as the LPS 1175 certificate guide explains.

The scope the report covers, and what sits outside it

The report covers the specimen as tested. Anything different from that specimen sits outside it unless the certification schedule covers it. Change the lock, the glazing, the hinges or the frame, and the doorset no longer matches the build that was tested, even when every part looks the same.

That is where the schedule matters. The certificate schedule names the configurations covered: the sizes, the hardware and the glazing the certification body has accepted. Ask for the schedule beside the report, and match each line of the order against it. A configuration that appears on neither the report nor the schedule needs fresh evidence, not an assurance.

Changes after certification need the certification authority told. The authority’s regular visits exist to catch components altered without its knowledge, and a change made quietly can void the certification it was meant to keep. The order should name the scope, and the security doors specification guide lists what the order must hold, so the doorset that arrives is the doorset that was tested.

The SBD listing: what it proves on its own

Police Preferred Specification means a product has passed a test against a relevant security standard and holds certification from an independent third-party body accredited by the United Kingdom Accreditation Service, or has been tested and certified by an approved body. More than 700 member companies hold the status, with thousands of products listed.

The listing is checked on the Secured by Design website, not on a brochure. The SBD listing guide walks through the check. The scheme’s scope and its limits are explained in the Secured by Design guide.

A listing proves security only. Fire performance needs its own evidence: a doorset described as a fire door needs third-party certification for security, smoke and fire performance together. What each paper in the fire file proves is the subject of the fire door certification guide, and the dual-certified door guide explains the record that keeps both ratings valid in service.

Where the law points: Approved Document Q

Approved Document Q is statutory guidance for England covering security in dwellings. Requirement Q1 of the Building Regulations 2010 sits behind it, and the requirement applies to new dwellings only. The requirement is that reasonable provision is made against unauthorised access, to every home and to every part of a building that gives access to a flat within it.

The document covers the standards for doors and windows to resist physical attack by a burglar, including standards on being strong enough and fitted with appropriate hardware. The route it points to for doorsets is a design that has passed a test against the security requirements of PAS 24, and PAS 24:2022+A1:2024 is the edition in force.

The document was published in March 2015 and updated in November 2024. Since April 2023 the Building Safety Regulator has a duty under the Building Safety Act 2022 to keep the safety and standards of all buildings in England under review, which includes advising on updates to the Approved Documents. The gov.uk page for Approved Document Q carries the document and its publication history.

The questions to ask before you order

Ask for the report, not only the certificate. A supplier with genuine evidence produces both without hesitation, and a supplier who produces only the certificate may be hiding a report that names a different product.

Ask which edition the test used, and match the certificate date to it. Ask whether the schedule names the exact product on the order: leaf, frame, size range, glazing and hardware. Ask who certified it, and whether the certification body runs an accredited scheme with factory visits and re-tests. Ask what has changed since the test, and whether the certification authority was told.

Judge each piece of evidence on its own terms. The mixing standards guide shows how to write a tender that names three standards and the evidence each one needs. How a public buyer learns what the market can supply before the competition opens is the subject of the preliminary market engagement guide, and how the layers of a site fit together is covered in the layered security guide.

A report proves one specimen on one day. A certificate proves the range as it is made. Ask for both, and match both to the order.

What does a PAS 24 test report prove?

That one specimen, built as described in the report, passed the test against the standard and edition named. It does not prove the next unit off the line, or a different configuration of the same product.

What does certification add to a test report?

Range sampling, factory visits, regular re-tests and change control. The certification authority checks that the tested products represent what is supplied, and that no component has changed without its knowledge.

What sits outside a test report?

Anything different from the specimen tested: a different lock, glazing, hinge, frame or size. A configuration needs the certification schedule to cover it, or fresh evidence.

Does a Secured by Design listing prove fire performance?

No. The listing proves security only. A fire doorset needs separate third-party evidence covering security, smoke and fire.

What should a buyer ask for before ordering?

The report and the certificate schedule, the edition tested, the name of the certification body, and what has changed since the test. Match both papers to the order before it is placed.

Checking test evidence for a door order?Send the report, the certificate schedule, and the order they must prove.
Contact us for a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.