Fire Door Remediation Programme for Housing Providers
How a housing provider runs a fire door remediation programme: survey, replace or repair, the evidence pack and the Regulation 10 check record.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A fire door remediation programme is the planned work a housing provider runs when a survey finds fire doors that no longer hold fire and smoke back. It covers every block in the stock, and it ends with a file that proves each door is right.
- Regulation 10Communal doors every 3 months, flat entrance doors every 12 months, above 11 metres
- FD30SFlat entrance doors: 30 minutes with smoke seals
- 4 mmMaximum gap round the leaf, except at the threshold
- BS EN 1634-1Fire test for doorsets, current edition 2014 plus A1 2018
Start with the survey: one record per door
Every programme starts with a survey of the whole stock. Each door gets its own record: block, flat or room, leaf, frame, seals, closer and label. A record that names each door by its opening can be worked from; a record that only counts doors cannot. Our fire door inspection checklist sets out what a survey of one door should cover.
The survey follows the government guidance for a routine fire door check: damage to the leaf, frame or wall, glazing that no longer sits soundly, loose hinges and ironmongery, and seals that are damaged, painted over or no longer touching the frame. It measures the gap round the leaf, never more than 4 mm except at the threshold, and tests the self-closing device by opening the door fully and letting it go.
Access needs a plan of its own, because flat entrance doors can only be checked on both sides with the resident’s agreement.
Read the findings against the fire risk assessment
A survey finding is not a verdict on its own. The fire risk assessment has already judged whether the doors are adequate to resist the spread of fire and smoke into the common parts, and the findings should be read against it. A door that satisfied the standards in force when the block was built will in most cases still protect the escape route, provided it is undamaged and the gaps round it are not too large.
The government guidance is clear about this. The Fire Safety (England) Regulations 2022 do not require existing flat entrance doors to meet the standards for new doors under the Building Regulations. The absence of intumescent strips, smoke seals or any form of certification does not on its own mean the door is unfit for purpose. A programme that replaces every uncertified door spends money the regulations never asked for.
The findings that demand action are the ones that break the door’s function: a leaf that is split, warped or holed, a frame that has moved, a closer that no longer shuts the door, a gap wider than 4 mm, or a door a resident has replaced with one that is not fire-resisting.
Sort every finding into replace, repair or adjust
Each finding falls into one of three groups. Replace where the leaf or frame is damaged beyond repair, where the door has warped out of its frame, or where a non-fire-resisting door has been fitted in place of a fire door. A replacement doorset must be tested as one assembly, leaf, frame, seals and ironmongery together, and must carry the rating the opening needs. Our fire rated steel doors range shows what a tested steel doorset carries.
Repair where the door itself is sound and a part has failed. Worn seals, a tired closer, loose hinges, a damaged letterbox or a cracked vision panel can usually be put right without taking the door out, following the approved repair techniques of the certification scheme the door carries, and the work should be recorded door by door. Adjust where only the setting has drifted: a closer that needs its speed reset, a latch that no longer catches, or a gap grown as a hinge has settled. The guidance expects repair or replacement by a competent contractor as soon as reasonably practicable.
Put the highest risk first
A programme with hundreds of doors cannot do them all at once. Doors on the escape route come first: flat entrance doors, doors to stairways and lobbies, and doors that sub-divide long corridors. A door that does not close is more urgent than a door with a worn seal, and a door on a stair serving ten flats is more urgent than a door on a cupboard.
Phasing should follow the building, not the spreadsheet. Work through one block at a time so residents see the work start and finish, and the record for that block is complete before the next begins. Bring forward any block with a high proportion of failed doors; where the findings are mostly adjustments, a single visit can clear a whole stair core.
Write the evidence pack for every door
Each door replaced or repaired needs its own evidence. For a replacement, the pack holds the certificate for the doorset, the label on the leaf, and the test evidence that proves the rating, tested to BS EN 1634-1 and classified under BS EN 13501-2. The certificate should name the sizes, configuration, locks and fixings the test covered, and the door that arrives should match them. Our fire door certification guide sets out what each paper should show.
For a repair, the pack holds the record of what was done, the parts used, the date and the contractor. Third-party certification schemes cover this work from both sides: product schemes such as Certifire and BM TRADA Q-Mark certify the doorset, and installer schemes such as FIRAS and BM TRADA Q-Mark certify the company that fitted or repaired it. Ask for the certificate number and check it on the scheme’s public register.
Keep the record the regulations ask for
Two duties under Regulation 10 run beside the programme. The responsible person must give every resident information about fire doors: keep them shut when not in use, leave the self-closing device alone, and report damage at once. New residents must get that information as soon as reasonably practicable, and all residents must be reminded at intervals of not more than 12 months. Our flat entrance doors guide sets out what the 2022 regulations ask for in blocks.
The second duty is the record of the checks themselves. Over every 12 month period, the responsible person must keep a record of the checks made on flat entrance doors, including the cases where access was not granted. A programme that keeps its survey records, appointment letters, access attempts and completed work on one file per block is already keeping the record the regulations ask for.
Re-inspect after the work and close the loop
No door leaves the programme until it has been checked again. A replacement should be checked against its certificate: size, configuration, locks and fixings should match the test evidence, and the self-closing device should shut the door fully from any angle. A repair should be checked the same way: the seal should touch the frame, the gap should be within 4 mm, and the closer should latch the door. Our fire door maintenance guide sets out the routine that keeps the rating honest.
The re-inspection closes the finding. The record for that door moves from “found” to “done”, with the date, the evidence and who checked it. Doors that fail go back into the programme, not onto a shelf. Once the last door is closed, the programme becomes the routine: the quarterly and annual checks continue, and the next survey starts from the file the programme built.
Does every flat entrance door need replacing?
No. The government guidance says existing flat entrance doors need not meet the standards for new doors. A door that met the standards when the block was built will usually still protect the escape route if it is undamaged and the gaps are not too large. Replace the damaged, warped or non-fire-resisting doors, and repair the rest.
How often must fire doors in a block be checked?
In England, where the top storey is above 11 metres, communal fire doors must be checked at least every 3 months and flat entrance doors at least every 12 months, on a best-endeavours basis. Resident information must be repeated every year.
What gap is allowed round a fire door?
The gap between the leaf and the frame should never be more than 4 mm, except at the threshold, where it should be as small as practicable. A gap wider than 4 mm is a finding the programme should act on.
Can a fire door be repaired instead of replaced?
Yes, where the leaf and frame are sound and only a part has failed. Worn seals, a tired closer, loose hinges and a damaged letterbox can usually be repaired, following the repair techniques its certification scheme approves. Record the repair door by door and re-inspect after the work.
What evidence should the file hold for each door?
For a replacement, the certificate, the label and the test evidence to BS EN 1634-1, with the sizes and configuration the test covered. For a repair, the record of the work and who did it, with the date. For every door, the survey record and the Regulation 10 check record.