Sectional door guide: panels, tracks and springs, insulation, fire and security proofs, automation, safety devices and one schedule for the site.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A sectional door is made of panels that rise overhead and stack flat under the ceiling, and it is the door a warehouse or a workshop puts on a loading bay. It opens a wide entrance without swinging into the yard or sliding along the wall, so the vehicles keep moving and the bay keeps working.
The door is the largest moving part on the building, and it takes the weather, the forklifts and the daily cycle on the same leaf. A door that sticks, drags or drops in its tracks stops the bay, so the panels, the tracks and the springs matter as much as the leaf itself.
The bays where these doors sit are covered in our loading bay doors guide, and the warehouses and logistics sector page covers the buildings the doors protect.
- BS EN 12453Safety in use of power operated doors
- LPS 1175 B3 / C5 / D10Forced entry ratings, three, five and ten minutes
- FD30 / FD60Fire resistance periods tested to EN 1634-1
- ISO 22343-1Vehicle security barrier ratings
Loading bays and vehicle entrances: where a sectional door earns its keep
A loading bay takes lorries all day, and the door on it must open fast, close tight and take the knocks from the vehicles that dock against it. A sectional door suits the bay because the panels rise overhead, so no leaf swings into the yard and no track crosses the lane the lorries use.
The size of the opening decides the door. A bay for a single lorry takes a smaller door than a bay for two lorries side by side, and the height of the opening decides the panels, because a taller door needs more panels and a stronger spring to lift them.
A pedestrian door beside the sectional door keeps staff off the lorry route, and the door goes on the same order as the sectional door. The warehouse security doors guide covers the doors on the building itself, and the warehouses fire door regulations guide sets out the periods for the doors inside the building. The security gates page covers the gate lines on the boundary, and our anti-ram gates and barriers guide works through the options for the vehicle line beside the bay.
Panels, tracks and springs: the parts a sectional door depends on
The panels carry the door, and each panel must hold its shape through the daily cycle. A panel that bends or cracks lets the door drag in its tracks, so the panel, the hinges between the panels and the rollers that run in the tracks all belong on the schedule beside the leaf.
The springs do the lifting, and a spring that is wrong for the weight of the door leaves the motor doing work it was never meant to do. The spring should be chosen for the panels that are fitted, and the tension should be checked on the service visit, because a spring that has lost its pull leaves the door heavy and slow.
The tracks guide the panels from the floor to the ceiling, and a track that is bent, dirty or out of line stops the door where it stands. The tracks belong on the inspection round beside the springs, and the record should name the track, the fault and the date it was fixed.
When the spring loses its pull, the motor takes the strain
A sectional door opens on its springs long before the motor earns its keep. The springs carry the weight of the panels as they rise, and the motor only guides the travel once the weight is balanced. Over years of daily cycles the pull of a spring fades a little at a time, and nobody on the bay notices the change until the motor starts to labour on the first lift of the morning.
Watch the door as it rises from shut. A balanced doorset lifts away from the floor without a jerk and holds its place halfway up when the motor stops. A doorset that drops back towards the floor, or one that needs a push to get moving, is asking for its springs to be checked before the motor is blamed. The check belongs on the service round, and the reading goes on the record beside the date, so the next visit can see whether the pull has faded further.
Never adjust a spring from a ladder with a spanner from the van. The stored force in a wound spring can throw a bar across the bay, and the adjustment belongs to the person trained for it, with the door locked shut and the bay clear. For the round itself, the maintenance checklist walks through springs, tracks and seals in the order a visit follows them, and the high speed doors guide runs through the doorsets built to cycle faster through the same opening.
A panel that sticks tells the round where to look first
A panel that sticks on its way up is telling the round exactly where the trouble sits. Rollers wear flat on one side, hinge pins dry out, and a joint between two panels picks up grit from the yard. Each fault leaves its own mark: a flat roller judders at the same height on every lift, a dry hinge creaks as the panels bend round the curve, and grit in a joint shows as a scrape along the panel edge.
Clean the tracks before anything is oiled. A brush down the full run of each track clears the dust and grit that grinds the rollers, and the rollers themselves are checked for play by hand, one at a time, with the door held shut. A roller that wobbles on its pin is changed on the visit, not left for the next one, because a wobbling roller chews the track it runs in. The loading bay doors guide names the other doors that share the bay, while the warehouse security doors guide deals with the doors fitted to the building itself.
Keep a short list on the bay wall of what the round found and what was changed, with the date beside each line. A door that sticks in the same place twice in a season is not suffering bad luck; it is pointing at a track that has moved or a panel that has taken a knock from a forklift. The cold store doors guide deals with the insulated doorsets that serve the cold rooms off the bay. For a tested door quotation, send the bay measurements with the clear height of each opening, and the enquiry checklist shows what each line of the order should carry.
| Sign on the bay | Likely cause | Round action |
|---|---|---|
| Door drops back when the motor stops | Spring pull has faded | Book a trained spring check |
| Judder at the same height each lift | Roller worn flat | Change the roller on the visit |
| Creak as panels bend round the curve | Dry hinge pin | Clean, then lubricate the pin |
| Scrape along a panel edge | Grit in the joint | Brush the tracks and the joint |
The track decides where the panels sit when the door stands open
The panels on a sectional door do not rise straight up. They follow a track, and the track decides where the panels sit when the door stands open. A standard lift track takes the panels just below the ceiling, so the door needs clear headroom above the opening and a ceiling free of ducts and lights where the panels run back. A bay with that space suits a standard lift, and the track stays simple.
A high lift track raises the panels higher before they run back, so the wall above the opening stays free for racking, a crane rail or a sign. A vertical lift track runs the panels straight up the wall, so the door suits a tall bay where the wall runs high and the ceiling holds nothing the panels would meet. A low headroom track bends the panels back sooner, so the door suits a bay where a beam or a duct crosses above the opening.
The lift belongs on the order beside the clear height of the bay, the obstructions above the opening and the use of the wall. A door ordered without the lift named leaves the fitter to guess, and a guess that puts the panels against a duct stops the bay. The high speed doors guide covers the leaves that cycle faster through the same opening, and the loading bay doors guide runs through the doors that share the bay with the sectional leaf.
The bay is measured twice because the track forgives nothing
Measure the bay before the door is ordered, and measure the opening the wall leaves, not the old door that hangs in it. The width and the height of the structural opening set the size of the leaf, and the piers each side set the room the tracks need. A pier too narrow for the track leaves the door short of its opening, and the fixings that hold the track need solid wall behind them.
Walk the bay and note what crosses above the opening. A beam, a duct, a light fitting or a sprinkler pipe each takes headroom the panels need, and a crane rail above the bay takes the wall the high lift track would use. The floor matters as well: a floor that falls across the opening leaves the bottom seal short on one side, so the floor level belongs on the schedule beside the width and the height. The fire door inspection checklist covers the same round of checks for the doors on the site.
Ask the supplier what clearances the track needs and what fixing the lintel takes, and write both answers beside the lift type on the order. For the doors on the building itself, the warehouse security doors guide has the full brief, and the security door maintenance checklist walks through the checks that keep the tracks, springs and seals working for the life of the door. The cold store doors guide covers the insulated leaves on the bays that feed cold rooms. Send the bay measurements and the clear height of each opening for a tested door quotation, and we reply within one working day.
| Lift | Where the panels sit | Bay it suits |
|---|---|---|
| Standard lift | Just below the ceiling | Bay with clear headroom |
| High lift | Higher, wall above opening stays free | Bay with racking or a crane rail |
| Vertical lift | Straight up the wall | Tall bay with high walls |
| Low headroom | Back sooner, below the obstruction | Bay with a beam or duct above |
Insulation and the thermal break: keeping the cold out of the bay
A sectional door on a heated building must keep the cold out, and the panels carry the insulation that does it. A panel with an insulated core holds the heat inside the bay, and a panel without one lets the heat out through the largest opening in the building.
The thermal break stops the cold travelling through the metal from the outside face to the inside face. A door without a break carries the cold straight through the panel, and the inside face drips with condensation, so the break belongs on the order beside the insulation. The fire rated windows guide covers the windows that share the same wall.
The seals round the door matter as much as the panels. A seal at the top, the sides and the floor keeps the draught out, and a seal that has perished or pulled away leaves a gap the wind uses, so the seals belong on the inspection round beside the tracks.
A sectional door that must hold fire and resist attack: the two proofs on one leaf
A sectional door on a compartment wall must hold fire back for its period, and a door on the boundary must resist a forced entry, and a door that must do both needs a proof for each job. Fire is proved to EN 1634-1, with FD30 or FD60 and the letters E, EW or EI naming what the furnace measured, and forced entry is proved to LPS 1175. The fire rated steel doors guide covers the steel leaves that carry the higher periods.
LPS 1175 grades the forced entry side, B3 for three minutes against category B tools, C5 for five minutes against category C tools and D10 for ten minutes against category D tools, under Issue 8.2, dated September 2024. The two proofs sit on the same schedule line, because a door proved for one job and not the other leaves the building open on one side.
The frame and the fixings carry the rating as much as the panels do, because the proof names the whole doorset as fitted. A panel proved to the rating, set in a frame that was never tested with it, has no rating, and the fixings that tie the frame to the wall belong on the same line as the panels. How the two proofs sit together is worked through in our fire and security doors dual certification guide.
Automation and safety devices: the door that must stop for a person
A powered sectional door is a machine, and BS EN 12453 sets out how it must be made safe to use. Photocells across the opening, a safety edge on the bottom panel and a limit on the force the door may exert each stop the door when a person or a vehicle is in its way.
Each device watches a different danger. The edge on the bottom panel stops the door when it meets something, the photocell stops it before it meets anything, and the loop in the floor holds it open while a vehicle waits underneath, so a door without all three has a gap in its safety.
The safety devices must be proved with the door, not bought separately and fitted later. A photocell set too low, an edge that does not reach the floor or a loop that does not see a small van each leaves the door unsafe, so the test report must name the devices with the door. Our gate automation guide covers how a powered barrier is driven and released. The fire door inspection checklist sets out the checks each round should make.
Access control for the bay: who opens the door, and when
The bay door should open for the vehicles that belong there and stay shut for the rest. A loop in the ground opens it for a lorry that approaches, a card or a fob opens it for the staff who use the bay every day, and an intercom at the bay lets a visitor ask to be let in.
Run the bay door on the same system as the rest of the site, so one card opens the bay, the staff areas and the yard, and one stopped card stops working everywhere at once. Our security turnstiles guide covers readers, fobs and biometrics in the lane. The choosing HVM bollards guide works through the options for the line beside the bay, and the bollard cost factors guide covers what each step up the line adds to the build.
A power cut must not trap a lorry in the bay or a person behind the door, so the manual release has to be written into the order beside the motor, and the release must work on power failure as well as on alarm.
Wind, weather and the door that faces the yard
A sectional door faces the yard and the weather, so the panels, the seals and the fixings must hold against the wind the site sees. A tall door on an exposed site takes more wind than a small door in a sheltered yard, and the door should be chosen for the gusts the site sees, not for the calm days between them. The road blockers guide covers the blockers that rise from the road, and the ratings in full are in our ISO 22343 vehicle security barriers guide.
Rain and frost work on the door every winter. A seal that has perished lets water under the bottom panel, and water under the panel freezes the door to the floor, so the seals and the drainage in front of the bay belong on the inspection round beside the tracks.
Choose the finish for the weather the site sees, because a panel that faces the yard all year needs a coating that lasts, and a coating that has failed lets the weather at the steel underneath.
The sectional door order: one schedule for the whole site
Write the enquiry as one schedule with a line for every door on the site, and put the position, the size and the panels, the rating, the motor and the drive, the safety devices and the access control on each line, so the door that arrives is the door that was proved.
Keep the test report, the rating and the service schedule with the door from the day it arrives, and write the inspection routine into the handover pack, so the next team can see what was proved and what must be checked. Our roller shutter cost factors guide works through what each step up the scale adds to the build, and the keeping an LPS 1175 rating valid guide sets out what breaks a rating. The sliding vehicle gates page covers the gates that run on a track.
| Position | Door | Rating | What to check |
|---|---|---|---|
| Loading bay | Sectional door | LPS 1175 C5 | Panels, tracks, springs |
| Vehicle entrance | Sectional door | ISO 22343-1 | Frame, fixings, release |
| Workshop door | Insulated sectional door | FD30 | Seals, closer, latch |
| Service yard | Sectional door | LPS 1175 B3 | Motor, loops, photocells |
| Cold store bay | Insulated sectional door | FD60 | Seals, panels, fixings |
A sectional door is the largest moving part on the building, so the panels, the tracks, the springs and the safety devices must all sit on the same schedule.
What is a sectional door?
A door made of panels that rise overhead and stack flat under the ceiling, so a wide entrance opens without a leaf swinging into the yard or sliding along the wall.
Can a sectional door hold a fire rating?
Yes, where the door is tested for the job. Fire is proved to EN 1634-1, with FD30 or FD60 and the letters E, EW or EI naming what the furnace measured.
Do powered sectional doors need safety devices?
Yes. BS EN 12453 sets out the safety in use of power operated doors, and photocells, safety edges and loops each stop the door when a person or a vehicle is in the way.
What happens to a sectional door in a power cut?
The door must release when the power fails, so a lorry in the bay and a person behind the door can both get out, and the manual release is written into the order beside the motor.
Who checks sectional doors?
The site team keeps the doors on the plan the maintenance schedule sets, and the file for each door names the fault found, the repair made and the date it was put right.
To get one quote for every opening, use the security door enquiry checklist and send the list in one go.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.