ArxBridge
LPS 1175 vs ASTM F2781 and Other US Ratings Explained
How LPS 1175 and ASTM F2781 test forced entry, where UL 752 and ASTM F1233 fit, and which rating to name on UK projects and US-specified work.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A UK specifier who sees ASTM F2781 on one drawing and LPS 1175 on the next is looking at two standards that answer the same question in different ways. Both ask how long a product holds against a person with tools. Both give the answer as a rating that can be written into a specification. The ratings do not mean the same thing, the products they cover are not the same, and one cannot be swapped for the other by reading the numbers side by side. A fence rated to ASTM F2781 has passed a fence test. The letters and the minutes look alike, and the tests behind them are not.
LPS 1175 is the UK standard for rating resistance to forced entry. It is published by LPCB, and Issue 8.2 is the current issue. It covers intruder resistant building components, strongpoints, security enclosures and free-standing barriers, from doors and windows to gates, grilles, fences and walls. Every rating has two parts: a letter for the tool category, from A to H, and a number for the minutes of attack time the product must resist. Our LPS 1175 standard page carries the full rating table, and our LPS 1175 Issue 8 guide works through how the old SR1 to SR8 labels map to the new codes.
ASTM F2781 is a US practice for testing security fence systems. Its full title is Standard Practice for Testing Forced Entry, Ballistic and Low Impact Resistance of Security Fence Systems, and the current edition is F2781-15, reapproved in 2021. It rates fence systems against three threat levels, Low, Medium and Aggressive, with ratings that run to 60 minutes. It also covers ballistic and low impact resistance of the same fence systems. It does not cover doors, windows or grilles, and a rating earned on a fence says nothing about a door. Our LPS 1175 vs PAS 24 guide covers the other UK comparison specifiers meet most often, and our LPS 1175 vs EN 1627 guide covers the European burglar resistance standard that sits beside LPS 1175 on UK projects.
- LPS 1175UK forced entry standard, A1 to H20
- ASTM F2781US fence test, threat levels L, M and A
- UL 752US bullet resisting equipment, Levels 1 to 10
- ASTM F1233US security glazing, Classes I to V
Two standards, two different jobs
LPS 1175 starts from the building. Its scope lists the parts of a building that can be attacked by hand: hinged and pivot doors, sliding doors, folding doors, garage doors, windows, secondary glazing, shutters, grilles and blinds, curtain walling, cladding, roofing, roof lights, strongpoints, cabinets and enclosures, and walls. It also lists free-standing barriers: fences, gates, turnstiles, revolving doors and portals.
ASTM F2781 starts from the fence line. It was written to evaluate the penetration resistance of standard fence systems for commercial, government and military installations, and its test specimen is a length of fence. The standard itself says the procedures give a basis for the comparative evaluation of different fence systems, and that they are not intended to establish or confirm the absolute prevention of forced entries. That is an honest limit, and it applies to every forced entry test: a rating states how long a product held in the test, not that it can never be beaten.
The two standards also come from different bodies with different standing. LPCB is the UK certification body for fire and security products, and an LPS 1175 rating is issued with certification and a listing that can be checked. ASTM International publishes test methods and practices that a laboratory follows, and the result is a test report against the stated threat level and time. Our guide to keeping an LPS 1175 rating valid sets out what can void a rating after handover, and our 10 steps to specify an LPS 1175 door works through the evidence to ask for before the order is placed.
How LPS 1175 tests a product
An LPS 1175 test is an attack by a small independent test team using only the tools permitted for the rating being tested, for the stated number of minutes. The product must resist for the full time. The team attacks the locked product as it would be installed, including the frame, the fixings, the locks and the hardware, because an attacker in the real world attacks the weakest point, not the strongest panel.
The letter names the tool category. Category A is opportunist attack with basic hand tools. Category B covers hand tools such as screwdrivers, pliers and hand saws. Category C covers tools such as crowbars, drills and chisels. Category D covers tools such as sledgehammers, disc cutters and jigsaws. Categories E, F and G use tool sets above the category before them, and category H covers extreme tools. The number names the minutes of attack time. A1 is one minute against category A tools, B3 is three minutes against category B, C5 is five minutes against category C, and D10 is ten minutes against category D. From D10 upward the attack time stays at ten minutes while the tool sets get heavier, and only H20 extends the time to twenty minutes.
The older SR labels still appear on drawings and certificates, and the mapping is fixed: A1 is the old SR1, B3 is SR2, C5 is SR3, D10 is SR4, E10 is SR5, F10 is SR6, G10 is SR7 and H20 is SR8. Our SR2 vs SR3 vs SR4 guide works through the three ratings specifiers meet most often, and our how to specify security doors guide covers the discipline of naming the rating in full.
| Issue 8 rating | Old label | Tool category | Attack time |
|---|---|---|---|
| A1 | SR1 | A: opportunist, basic hand tools | 1 minute |
| B3 | SR2 | B: screwdrivers, pliers, hand saws | 3 minutes |
| C5 | SR3 | C: crowbars, drills, chisels | 5 minutes |
| D10 | SR4 | D: sledgehammers, disc cutters, jigsaws | 10 minutes |
| E10 | SR5 | E: tool sets above category D | 10 minutes |
| F10 | SR6 | F: tool sets above category E | 10 minutes |
| G10 | SR7 | G: tool sets above category F | 10 minutes |
| H20 | SR8 | H: extreme tools | 20 minutes |
How ASTM F2781 tests a fence system
An ASTM F2781 test attacks a fence system in two parts. The structured portion runs for five minutes with specific tools chosen as the most debilitating from the tool list, regardless of the fence system being tested. The discretionary portion then runs for up to 55 minutes, with the test team choosing tools and attack points as the test goes on. The test team works against the fence as installed, including its posts, fixings and foundations, because a fence that holds its mesh but gives way at a post has failed.
The tool inventory is a hand tool list, and it reads like a forced entry kit: crowbars, cold chisels and hammers, hacksaws, sledgehammers, fire axes, bolt cutters, hole saws and pry bars. The threat level decides which tools are allowed. At the Low threat level, power tools of every kind are excluded, whether gasoline, electric or hydraulic, and so are devices needing more than one person to transport and operate. At the Medium threat level, power tools needing an outside power source or self contained gasoline or battery driven tools are excluded, and devices needing more than two persons are excluded. At the Aggressive threat level, devices needing more than two persons to transport and operate are excluded.
The number of people attacking is part of the test. The Low and Medium threat levels use two active test personnel, and the Aggressive level uses four. That matters when a rating is read, because a fence that held for 30 minutes against two attackers has not been shown to hold for 30 minutes against four. The rating also covers more than forced entry: the same practice tests ballistic resistance and low impact resistance of the fence system, and the low impact element gives relative guidance on the fence absorbing a stated kinetic energy figure. A specifier who only needs forced entry should ask which part of the F2781 rating the evidence covers, and not treat a ballistic or impact result as a forced entry result.
Reading an F2781 rating: L, M and A
An F2781 rating starts with a letter for the threat level and ends with the minutes the fence resisted. Low ratings run from L0 to L60, Medium from M0 to M60 and Aggressive from A0 to A60, in steps that follow the test schedule. A rating of L20 to L30 means the fence held for between 20 and 30 minutes against the Low threat level tools and team. A rating of A31 to A60 means the fence held for more than 30 minutes against the Aggressive threat level, with four attackers and the full tool inventory.
Two details catch specifiers out. First, the lowest ratings in each band start below five minutes, which is the length of the structured portion. A rating of L0 to L4.9 means the fence was penetrated during the structured five minute test. Second, the top of each band is 60 minutes, which is the longest the test runs. A fence rated L31 to L60 has held for more than half an hour, and the test stops at 60 minutes whether or not the fence would have held longer. The rating states what the test proved, not what the fence could do beyond the test.
UL 752 and ASTM F1233: ballistic and glazing ratings, not forced entry
Two other US ratings appear on UK drawings, and both are often mistaken for forced entry ratings. UL 752 is the US Standard for Bullet-Resisting Equipment. It rates materials and assemblies against bullets, in ten levels from Level 1 to Level 10. Level 1 stops three 9 mm rounds, Level 2 stops three .357 Magnum rounds, and Level 3 stops three .44 Magnum rounds. Levels 4 to 8 stop rifle rounds, from a single .30 calibre rifle shot at Level 4 to five 7.62 mm rifle shots at Level 8. Level 9 stops an armour piercing .30 calibre rifle shot, and Level 10 stops a .50 calibre rifle shot. A supplementary shotgun rating covers a 12-gauge rifled slug and 00 buckshot. The levels are not incremental: a material rated Level 5 has not necessarily passed the Level 4 test, because each level uses a different projectile and velocity. Our ballistic ratings page sets out the European equivalents, EN 1522 and EN 1063, which grade doors and glass against bullets in classes FB1 to FB7 and BR1 to BR7.
UL 752 says nothing about a person with a crowbar. Where the threat is forced entry, the rating to ask for is a forced entry rating. Where the threat is ballistic, the rating to ask for is a ballistic rating. Where both threats exist, the product needs both sets of evidence on the same assembly, and the two must be proved together, because a ballistic pane in an untested frame is not a rated assembly.
ASTM F1233 is the US Standard Test Method for Security Glazing Materials and Systems. It tests glazing against ballistic impact, blunt tool impacts, sharp tool impacts, thermal stress and chemical deterioration, and it assigns Classes I to V. Class I is a single forced entry sequence of ten ball peen hammer blows. Class V is 41 sequences, including 50 fire axe impacts, and the test has no overall time limit: testing continues until the glazing fails. Power tools and explosives are excluded from the test. F1233 is a glazing test, so it rates the glass and the glazing system, not the door or the window frame around it. A Class V pane in a frame that was never tested is not a Class V window. Two related US methods sit beside it: ASTM F3038, a timed evaluation of forced entry resistant systems, and ASTM F3561, which tests a fenestration system for forced entry resistance after a simulated ballistic assault, with glazing and framing tested together. The US Department of State also publishes SD-STD-01.01, which covers forced entry and ballistic resistance of structural systems.
Which rating to name on a UK project
On a UK project, name LPS 1175 Issue 8.2, with the letter and the minutes in full. Write the rating as it appears on the certificate, for example B3 or D10, and name Issue 8.2 so that designers, bidders and checkers are all working to the same edition. Name the product the rating covers, and name the configuration: the leaf, the frame, the glass, the fixings and the hardware as one tested assembly.
Match the rating to the opening, not to the building. A front entrance that faces a public street needs a different rating from a plant room door at the back of the same building, and a ground floor window needs a different rating from a window on the third floor. The risk assessment names the threat for each opening, and the rating follows from it. A higher rating is not always better: a rating above the threat wastes the budget that could have gone to the next opening, and a rating below the threat leaves the weakest opening as the route in. Our SR2 vs SR3 vs SR4 guide works through how to match the rating to the building, and the response time behind the delay matters as much as the delay itself: a rating buys minutes, and the minutes only help if someone responds inside them.
Ask for the evidence before the order is placed. The test report and the listing should name the exact product, its configuration and its options, and the rating on the certificate should match the rating in the specification. Check the listing in the LPCB Red Book, and check that the certificate is current for the product being supplied. A certificate for a different model does not cover the order, and a product described as tested to LPS 1175 without a certificate has no proven rating at all.
Which rating to name on a US-specified project
On a project specified to US standards, name the ASTM standard and the rating exactly as the standard writes it. For a fence, name ASTM F2781 with the threat level and the rating band, for example M20 to M30, and name the fence system, its posts, its fixings and its foundations. For glazing, name ASTM F1233 with the class, for example Class III, and name the glazing system including the frame. For ballistic protection, name UL 752 with the level, for example Level 3, and name the material and the assembly it sits in.
Where a project carries both UK and US requirements, write both ratings in the specification and ask for evidence for each. A product can hold an LPS 1175 rating and a US rating at the same time, but only where both tests were run on the same construction. One test does not prove the other, and a product that passed LPS 1175 has not been shown to pass ASTM F2781, just as a fence that passed ASTM F2781 has not been shown to pass LPS 1175. The two tests use different tools, different teams and different times, and no published table converts one rating into the other. Any supplier who offers a conversion is offering an opinion, not a test result.
Mistakes when a US rating lands on a UK specification
The most common mistake is reading the numbers as if they were the same scale. An F2781 rating of 60 minutes looks stronger than an LPS 1175 rating of 10 minutes, but the two numbers come from different tests on different products with different teams. A 60 minute fence rating and a 10 minute door rating cannot be compared, because the fence test and the door test ask different questions. The right comparison is between two products tested to the same standard, at the same rating, on the same type of opening.
The second mistake is taking a rating for one product and applying it to another. An F2781 fence rating does not cover the gate in the same fence line, a UL 752 ballistic rating does not cover forced entry, and an F1233 glazing class does not cover the window frame. Each rating belongs to the product and the assembly it was tested on.
A rating is a test result, not a promise. It states how long one tested assembly held against one stated attack, and nothing more.
Is ASTM F2781 the US equivalent of LPS 1175?
No. ASTM F2781 is a US practice for testing security fence systems, and LPS 1175 is a UK standard for intruder resistant building components, strongpoints, security enclosures and free-standing barriers. The two cover different products, use different tools, teams and times, and no published table converts one rating into the other. A product needs evidence under each standard it is specified to.
What does an F2781 rating of L20 to L30 mean?
It means the fence system held for between 20 and 30 minutes against the Low threat level in ASTM F2781, with two active test personnel and hand tools only, power tools excluded. The letter names the threat level and the numbers name the cumulative minutes the fence resisted across the structured and discretionary portions of the test.
Does UL 752 cover forced entry?
No. UL 752 is the US Standard for Bullet-Resisting Equipment, and it rates materials and assemblies against bullets in ten levels. It says nothing about a person with a crowbar. Where the threat is forced entry, ask for a forced entry rating such as LPS 1175 or ASTM F2781, and where both threats exist, ask for both sets of evidence on the same assembly.
Can one product hold both an LPS 1175 rating and a US rating?
Yes, where both tests were run on the same construction. One test does not prove the other, so the specification should name both ratings and the evidence should show both tests on the same product and configuration. A certificate for one standard does not cover the other.
Which rating should a UK project name for a fence?
LPS 1175 Issue 8.2, with the letter and the minutes in full, for example C5. LPS 1175 covers fencing systems and gates as free-standing barriers, and the rating should name the fence system, its posts, its fixings and its foundations. An ASTM F2781 rating can be named beside it where a US client asks for it, but it does not replace the LPS 1175 rating on a UK project.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.